uu.seUppsala University Publications
Change search
ReferencesLink to record
Permanent link

Direct link
The Artelon CMC spacer compared with tendon interposition arthroplasty: A randomized, controlled, multicenter study of 109 patients with osteoarthritis followed for 1 year
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Hand Surgery.
Show others and affiliations
2010 (English)In: Acta Orthopaedica, ISSN 1745-3674, E-ISSN 1745-3682, Vol. 81, no 2, 239-246 p.Article in journal (Refereed) Published
Abstract [en]

Background and purpose The Artelon CMC spacer is designed for surgical treatment of osteoarthritis (OA) in the carpometacarpal joint of the thumb (CMC-I). Good results using this degradable device were previously presented in a pilot study. We now present results from a larger randomized, controlled, multicenter study. Patients and methods 109 patients (94 females) with a mean age of 60 (42-83) years, suffering from painful CMC OA, were included in the study at 7 centers in Sweden. The patients were randomized to Artelon CMC spacer (test, n = 72) or tendon arthroplasty (control, n = 37) at a ratio of 2:1. Perceived pain was recorded on a visual analog scale (VAS) before treatment and after 3, 6, and 12 months, when measuring maximal tripod pinch strength (primary outcome measure). In addition, range of motion, radiographic findings, and functional testing were recorded pre- and postoperatively. Results Swelling and pain were more common in the test group and 6 implants were removed because of such symptoms. 5 of these patients did not receive antibiotics preoperatively according to the study protocol. In a per-protocol analysis, i.e. patients without signs of concomitant OA in the scaphoid-trapezium-trapezoid (STT) joint and those in the test group who received antibiotics, the mean difference in tripod pinch strength increase, adjusted for baseline, was 1.4 kg in favor of the test group (not statistically significant). Statistically significant pain relief was achieved in both groups, with perceived pain gradually decreasing during the follow-up period. In the intention-to-treat analysis but not in the per-protocol analysis, significantly better pain relief (VAS) was obtained in the control group. Patient-perceived disability evaluated by the DASH questionnaire improved in both groups. Interpretation The Artelon CMC spacer did not show superior results compared to tendon interposition arthroplasty. Proper use of preoperative antibiotics and a thorough patient selection appear to be important for the results.

Place, publisher, year, edition, pages
2010. Vol. 81, no 2, 239-246 p.
National Category
Medical and Health Sciences
URN: urn:nbn:se:uu:diva-137096DOI: 10.3109/17453671003635835ISI: 000276361700015OAI: oai:DiVA.org:uu-137096DiVA: diva2:377963
Available from: 2010-12-15 Created: 2010-12-15 Last updated: 2010-12-15Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text
By organisation
Hand Surgery
In the same journal
Acta Orthopaedica
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 147 hits
ReferencesLink to record
Permanent link

Direct link