uu.seUppsala University Publications
Change search
ReferencesLink to record
Permanent link

Direct link
The role of whole blood in thrombin generation in contact with various titanium surfaces
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Oral and Maxillofacial Surgery.
Biomaterialvetenskap Göteborgs universitet.
Biomaterialvetenskap Göteborgs universitet.
Biomaterialvetenskap Göteborgs universitet.
Show others and affiliations
2007 (English)In: Biomaterials, ISSN 0142-9612, E-ISSN 1878-5905, Vol. 28, no 6, 966-974 p.Article in journal (Refereed) Published
Abstract [en]

Understanding of the thrombotic response (activation of the intrinsic coagulation system followed by platelet activation) from blood components upon contact with a titanium dental implant is important and not fully understood. The aims of this study were to evaluate: (1) the thrombogenic response of whole blood, platelet-rich plasma (PRP) and platelet-poor plasma (PPP) in contact with a highly thrombogenic surface as titanium, (2) the thrombogenic response of clinically used surfaces as hydroxyapatite (HA), machined titanium (mTi), TiO2 grit-blasted titanium (TiOB) and fluoride ion-modified grit-blasted titanium (TiOB-F). An in vitro slide chamber model, furnished with heparin, was used in which whole blood, PRP or PPP came in contact with slides of the test surfaces. After incubation (60 min rotation at 22 rpm in a 37 degrees C water bath), blood/plasma was mixed with EDTA or citrate, further centrifuged at +4 degrees C (2200 g at 10 min). Finally, plasma was collected pending analysis. Whole blood in contact with Ti alloy resulted in the binding of platelets to the material surface and in the generation of thrombin-antithrombin (TAT) complexes. With whole blood TAT levels increased 1000-fold compared with PRP and PPP, in which both almost no increase of TAT could be detected. In addition, the platelet activation showed a similar pattern with a 15-fold higher release of beta-TG in whole blood. In the in vitro chamber model with the clinically relevant materials, the fluoride-modified surface (TiOB-F) showed pronounced TAT generation compared with TiOB, mTi and HA. Similar results were achieved for platelet consumption and activation markers of the intrinsic coagulation system. Taken together these results implicate first that whole blood is necessary for sufficient thrombin generation and platelet activation during placement of implants. Second, a fluoride ion modification seems to augment the thrombogenic properties of titanium.

Place, publisher, year, edition, pages
2007. Vol. 28, no 6, 966-974 p.
Keyword [en]
Dental implant, Coagulation, Platelet activation, Hydroxyapatite, Thrombogenicity, Complement
National Category
Medical and Health Sciences
URN: urn:nbn:se:uu:diva-12917DOI: 10.1016/j.biomaterials.2006.10.020ISI: 000243219000008PubMedID: 17095084OAI: oai:DiVA.org:uu-12917DiVA: diva2:40687
Available from: 2008-05-29 Created: 2008-05-29 Last updated: 2011-02-22Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Thor, AndreasNilsson, BoHong, Jaan
By organisation
Oral and Maxillofacial SurgeryClinical Immunology
In the same journal
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 294 hits
ReferencesLink to record
Permanent link

Direct link