uu.seUppsala University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Effects of measurement of plasma activity input on normalization of glomerular filtration rate to plasma volume in dogs
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Oncology, Radiology and Clinical Immunology, Avdelningen för sjukhusfysik.
2007 (English)In: Veterinary Radiology & Ultrasound, ISSN 1058-8183, E-ISSN 1740-8261, Vol. 48, no 6, 585-593 p.Article in journal (Refereed) Published
Abstract [en]

Glomerular filtration rate (GFR) normalized to body fluid volumes to adjust for differing body size and conformation is more physiologically correct than a relationship with body weight (BW). GFR can be normalized to plasma volume by a renographic method that uses the Rutland-Patlak plot with plasma activity and kidney activity inputs. A plasma time-activity curve is obtained from a region of interest (ROI) of the left ventricle (LV), the size of which is in theory not critical. The aims of the study were to evaluate the effect of different LV ROI sizes, the effect of extravascular activity in the thorax over the LV ROI, and different time intervals for the semilogarithmic LV plot. Seventy-two scintigrams were used, with three different-sized automatic and a manual LV ROI, all with and without subtracting extravascular activity, and with LV curve time intervals of 30-120 s and 60-240 s. GFR/plasma volume was not affected by LV ROI sizes but significantly affected by extravascular activity subtraction and different time intervals. Subtracting extravascular activity from the LV ROI did not improve precision, but increased variability caused by different LV ROI sizes and time intervals chosen for the LV plot. The ROI for measuring extravascular activity apparently contained a considerable and variable intravascular component, which when subtracted, created noisy and unreliable LV curves. Manual LV ROI, without extravascular subtraction, and a time interval for LV input between 1 and 4 min are recommended as they gave the least variability determined by statistical analysis. With these methods, normal individual GFR/plasma volume in normal beagle dogs was 29.2 +/- 6.5 ml/min/l.

Place, publisher, year, edition, pages
2007. Vol. 48, no 6, 585-593 p.
Keyword [en]
dogs, glomerular filtration rate, plasma volume, renal scintigraphy, technetium-99m dietylene-triaminepentaacetic acid
National Category
Veterinary Science
Identifiers
URN: urn:nbn:se:uu:diva-150964DOI: 10.1111/j.1740-8261.2007.00303.xISI: 000250364200017PubMedID: 18018735OAI: oai:DiVA.org:uu-150964DiVA: diva2:409480
Available from: 2011-04-08 Created: 2011-04-08 Last updated: 2017-12-11Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed
By organisation
Avdelningen för sjukhusfysik
In the same journal
Veterinary Radiology & Ultrasound
Veterinary Science

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 384 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf