Quantitative imaging of I-124 and Y-86 with PET
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Radiology, Oncology and Radiation Science, Section of Medical Physics.
2011 (English)In: European Journal of Nuclear Medicine and Molecular Imaging, ISSN 1619-7070, E-ISSN 1619-7089, Vol. 38, 10-18 p.Article, review/survey (Refereed) Published
Abstract [en]

The quantitative accuracy and image quality of positron emission tomography (PET) measurements with I-124 and Y-86 is affected by the prompt emission of gamma radiation and positrons in their decays, as well as the higher energy of the emitted positrons compared to those emitted by F-18. PET scanners cannot distinguish between true coincidences, involving two 511-keV annihilation photons, and coincidences involving one annihilation photon and a prompt gamma, if the energy of this prompt gamma is within the energy window of the scanner. The current review deals with a number of aspects of the challenge this poses for quantitative PET imaging. First, the effect of prompt gamma coincidences on quantitative accuracy of PET images is discussed and a number of suggested corrections are described. Then, the effect of prompt gamma coincidences and the increased singles count rates due to gamma radiation on the count rate performance of PET is addressed, as well as possible improvements based on modification of the scanner's energy windows. Finally, the effect of positron energy on spatial resolution and recovery is assessed. The methods presented in this overview aim to overcome the challenges associated with the decay characteristics of I-124 and Y-86. Careful application of the presented correction methods can allow for quantitatively accurate images with improved image contrast.

Place, publisher, year, edition, pages
2011. Vol. 38, 10-18 p.
Keyword [en]
PET, Positron emission tomography, Y-86, I-124, Quantitative imaging, Radionuclide therapy, Dosimetry
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:uu:diva-154610DOI: 10.1007/s00259-011-1768-2ISI: 000290807700003PubMedID: 21484385OAI: oai:DiVA.org:uu-154610DiVA: diva2:421554
Available from: 2011-06-09 Created: 2011-06-08 Last updated: 2017-12-11Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed
By organisation
Section of Medical Physics
In the same journal
European Journal of Nuclear Medicine and Molecular Imaging
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 397 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf