2011 (English)In: European Journal of Clinical Investigation, ISSN 0014-2972, E-ISSN 1365-2362, Vol. 41, no 10, 1063-1070 p.Article in journal (Refereed) Published
Abstract [en]

Background Nasal nitric oxide (nNO) is assessed by nasal aspiration/insufflation via one nostril or by nasal silent exhalation through a facemask and is also measured during humming, a manoeuvre that results in increased nNO in the presence of a patent osteomeatal complex. Humming nNO peak is absent in primary ciliary dyskinesia (PCD) and in cystic fibrosis (CF). Hand-held devices are used successfully for exhaled or nNO analysis. No study compared nNO during silent and humming exhalation using hand-held and stationary analysers. Methods Thirty-eight subjects (14 PCD; 11 CF; 13 healthy individuals) measured nNO with a stationary and a hand-held analyser during silent and humming exhalations. Results No difference between nNO obtained from stationary or hand-held analyser during silent and humming exhalation was found (P > 0 05). Patients with PCD exhibited lower silent and humming nNO than CF or controls (P < 0 001). During both silent and humming exhalation, there was a significant correlation between nNO from the two analyzers both in the whole study population and within each group (r >= 0.7, P < 0 01). Bland-Altman plots confirmed this agreement. Using the hand-held device during humming, nNO values of 50, 81 and 21 ppb had sensitivity and specificity > 90% for discriminating PCD or CF from healthy subjects, and patients with PCD from patients with CF, respectively. Conclusions The hand-held device is as effective as the stationary analyzer for assessing nNO during silent and humming exhalation. Its wider use might result in an increased number of subjects suspected to have PCD.

Place, publisher, year, edition, pages
2011. Vol. 41, no 10, 1063-1070 p.
Keyword [en]
Chemiluminescence, cystic fibrosis, electrochemical sensor, nasal nitric oxide, primary ciliary dyskinesia
National Category
Medical and Health Sciences
URN: urn:nbn:se:uu:diva-159458DOI: 10.1111/j.1365-2362.2011.02501.xISI: 000294912200004OAI: oai:DiVA.org:uu-159458DiVA: diva2:445592
Available from: 2011-10-04 Created: 2011-10-03 Last updated: 2012-03-14Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Search in DiVA

By author/editor
Alving, Kjell
By organisation
Department of Women's and Children's Health
In the same journal
European Journal of Clinical Investigation
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 134 hits
ReferencesLink to record
Permanent link

Direct link