Calculations of the energy distribution from perturbation peak data—A new tool for characterization of chromatographic phases
Uppsala University, Disciplinary Domain of Science and Technology, Chemistry, Department of Physical and Analytical Chemistry.
Uppsala University, Disciplinary Domain of Science and Technology, Chemistry, Department of Physical and Analytical Chemistry.
2008 (English)In: Journal of Chromatography A, ISSN 0021-9673, E-ISSN 1873-3778, Vol. 1203, no 2, 177-184 p.Article in journal (Refereed) Published
Abstract [en]

The calculation of the adsorption energy distribution (AED) was recently introduced as an important tool for the chromatographic community for characterization of modern phases. The AED-calculations, provides model-independent information about the numbers of different adsorption sites and their respective energy-levels, prior to the selection of an adsorption isotherm model which narrows the number of possible rival models. The selection of a proper model for the fitting of the determined raw data is crucial; if the wrong model is selected misleading information about the retention mechanism may be drawn. The AED-calculations require raw adsorption isotherm data (i.e. data points) which is unfortunately not obtained by the newly validated perturbation peak method. In this study, we developed mathematical expression allowing the use of the raw tangential slope provided by the perturbation peak method for AED calculations. The approach worked excellently and was verified against both computer-generated adsorption isotherm data as well as experimentally determined data, using three different experimental systems. Itwas found that the calculations of the AED, as based on perturbation peak data, converts faster and are not more sensitive to experimental noise as compared to the classical AED calculations using raw adsorption isotherm data.

Place, publisher, year, edition, pages
2008. Vol. 1203, no 2, 177-184 p.
Keyword [en]
adsorption energy distribution, adsorption isotherms, perturbation peak method, column characterization
National Category
Physical Chemistry
Identifiers
URN: urn:nbn:se:uu:diva-17851DOI: 10.1016/j.chroma.2008.07.045ISI: 000258972300008PubMedID: 18672247OAI: oai:DiVA.org:uu-17851DiVA: diva2:45622
Available from: 2008-09-05 Created: 2008-09-05 Last updated: 2017-12-08Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Authority records BETA

Samuelsson, JörgenFornstedt, Torgny

Search in DiVA

By author/editor
Samuelsson, JörgenFornstedt, Torgny
By organisation
Department of Physical and Analytical Chemistry
In the same journal
Journal of Chromatography A
Physical Chemistry

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 371 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf