Exhaled nitric oxide monitoring by quantum cascade laser: comparison with chemiluminescent and electrochemical sensors
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Sciences, Respiratory Medicine and Allergology. Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Medicinska och farmaceutiska vetenskapsområdet, centrumbildningar mm, Centre for Research and Development, Gävleborg.
Show others and affiliations
2012 (English)In: Journal of Biomedical Optics, ISSN 1083-3668, E-ISSN 1560-2281, Vol. 17, no 1, 017003- p.Article in journal (Refereed) Published
Abstract [en]

Fractional exhaled nitric oxide (FENO  ) is considered an indicator in the diagnostics and management of asthma. In this study we present a laser-based sensor for measuring FENO  . It consists of a quantum cascade laser (QCL) combined with a multi-pass cell and wavelength modulation spectroscopy for the detection of NO at the sub-part-per-billion by volume (ppbv, 1∶10-9) level. The characteristics and diagnostic performance of the sensor were assessed. A detection limit of 0.5 ppbv was demonstrated with a relatively simple design. The QCL-based sensor was compared with two market sensors, a chemiluminescent analyzer (NOA 280, Sievers) and a portable hand-held electrochemical analyzer (MINO®, Aerocrine AB, Sweden). FENO  from 20 children diagnosed with asthma and treated with inhaled corticosteroids were measured. Data were found to be clinically acceptable within 1.1 ppbv between the QCL-based sensor and chemiluminescent sensor and within 1.7 ppbv when compared to the electrochemical sensor. The QCL-based sensor was tested on healthy subjects at various expiratory flow rates for both online and offline sampling procedures. The extended NO parameters, i.e. the alveolar region, airway wall, diffusing capacity, and flux were calculated and showed a good agreement with the previously reported values.

Place, publisher, year, edition, pages
2012. Vol. 17, no 1, 017003- p.
National Category
Clinical Medicine
Identifiers
URN: urn:nbn:se:uu:diva-185322DOI: 10.1117/1.JBO.17.1.017003ISI: 000301608300040PubMedID: 22352669OAI: oai:DiVA.org:uu-185322DiVA: diva2:571273
Available from: 2012-11-22 Created: 2012-11-22 Last updated: 2017-12-07Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Authority records BETA

Högman, Marieann

Search in DiVA

By author/editor
Högman, Marieann
By organisation
Respiratory Medicine and AllergologyCentre for Research and Development, Gävleborg
In the same journal
Journal of Biomedical Optics
Clinical Medicine

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 372 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf