A modified Glenn shunt improves haemodynamics in acute right ventricular failure in an experimental model
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Thoracic Surgery.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Thoracic Surgery.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Anaesthesiology and Intensive Care.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Thoracic Surgery.
2013 (English)In: European Journal of Cardio-Thoracic Surgery, ISSN 1010-7940, E-ISSN 1873-734X, Vol. 43, no 3, 612-618 p.Article in journal (Refereed) Published
Abstract [en]

OBJECTIVES:

Right heart failure is a major cause of morbidity and mortality after left ventricular assist device implantation and is still hard to predict. This study investigated the haemodynamic effect of a modified Glenn shunt on induced right ventricular (RV) failure.

METHODS:

Isolated RV failure was induced by coronary ligation in 11 pigs. A modified Glenn shunt was established by a superior vena cava to pulmonary artery connection. Haemodynamic data were obtained at baseline, RV failure, and RV failure and open shunt. Myocardial biopsies were taken to ascertain established heart failure.

RESULTS:

RV failure defined as right atrial pressure ≥20 mmHg was achieved in all 11 animals. A reduction in cardiac output (CO) from 3.7 (3.5-4.2) to 2.3 l/min (2.0-2.6) and mean arterial pressure (MAP) from median 72.7 (70.1-82.2) to 55.9 mmHg (52.6-59.8) was seen during heart failure. The median flow in the shunt was 681 ml. Right atrial pressures decreased from 20.3 (19.6-21.1) to 13.4 mmHg (12.7-14.0), and RV pressures decreased from 18.1 (16.4-20.1) to 13.6 mmHg (13.5-14.2) with open shunt (P = 0.001 for both). CO increased to 2.9 l/min (2.4-3.3) when the shunt was in use. Mixed venous oxygen saturation increased with the shunt from 32 (27-38) to 49% (45-56), P = 0.001. Genes associated with heart failure were upregulated during heart failure.

CONCLUSIONS:

A modified Glenn shunt improved haemodynamics by reduced right atrial pressure, increased CO, MAP and mixed venous oxygen saturation in an experimental model of induced RV failure.

Place, publisher, year, edition, pages
2013. Vol. 43, no 3, 612-618 p.
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:uu:diva-188728DOI: 10.1093/ejcts/ezs386ISI: 000314852500038PubMedID: 22761503OAI: oai:DiVA.org:uu-188728DiVA: diva2:578810
Available from: 2012-12-19 Created: 2012-12-19 Last updated: 2017-12-06Bibliographically approved
In thesis
1. Treatment of Right Ventricular Failure through Partial Volume Exclusion: An Experimental Study
Open this publication in new window or tab >>Treatment of Right Ventricular Failure through Partial Volume Exclusion: An Experimental Study
2015 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Implantation of a left ventricular assist device (LVAD) is a potential treatment in terminal heart failure. Right ventricular (RV) failure is a severe complication in these patients and sometimes requires additional placement of a right ventricular assist device (RVAD). RVAD implantation, however, is an invasive treatment associated with both increased mortality and morbidity. The aim of this thesis was to study whether partial volume exclusion of the RV through a modified Glenn shunt or cavoaortic shunt could treat severe RV failure. The ultimate goal would be to use it as an alternative to a RVAD in RV failure during LVAD therapy.

Swine were used as the model animal in all studies. In Study I, experimental RV failure was induced by ischemia, and verified by hemodynamic measurements and genetic expression. Treatment with a modified Glenn shunt reduced venous stasis and improved hemodynamics in general. In Study II, experimental RV failure was induced by the same method as in Study I. Treatment with a cavoaortic shunt in addition to LVAD therapy proved to reduce venous stasis and improved hemodynamics in general, which was feasible with preserved oxygen delivery despite cyanotic shunting. In Study III, experimental RV failure was induced by pulmonary banding, and verified by hemodynamic measurements and genetic expression. Treatment with a modified Glenn shunt reduced venous stasis but did not improve hemodynamics in general compared with a control group. In Study IV, the effects of LVAD therapy and subsequent treatment with a modified Glenn shunt on the normal RV function were studied. It demonstrated that LVAD therapy can put strain on the RV by increasing stroke work and end-diastolic volume, and that these effects can be reversed by treatment with a modified Glenn shunt during LVAD therapy.

In conclusion, partial volume exclusion through a modified Glenn shunt or cavoaortic shunt is a feasible treatment of experimental RV failure. Thus, it could potentially be used as an alternative treatment to a RVAD in severe RV failure during LVAD therapy.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2015. 47 p.
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, ISSN 1651-6206 ; 1096
Keyword
Right Heart Failure, Left Ventricular Assist Device, Glenn shunt
National Category
Surgery
Research subject
Thorax Surgery
Identifiers
urn:nbn:se:uu:diva-248164 (URN)978-91-554-9228-1 (ISBN)
Public defence
2015-05-27, Robergsalen, Akademiska Sjukhuset, Uppsala, 13:00 (Swedish)
Opponent
Supervisors
Available from: 2015-05-05 Created: 2015-03-29 Last updated: 2015-07-07

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Authority records BETA

Vikholm, PerSchiller, PetterJohansson, JakobHellgren, Laila

Search in DiVA

By author/editor
Vikholm, PerSchiller, PetterJohansson, JakobHellgren, Laila
By organisation
Thoracic SurgeryAnaesthesiology and Intensive Care
In the same journal
European Journal of Cardio-Thoracic Surgery
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 556 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf