Comparison of dual-source computed tomography for the quantification of the aortic valve area in patients with aortic stenosis versus transthoracic echocardiography and invasive hemodynamic assessment
Show others and affiliations
2009 (English)In: American Journal of Cardiology, ISSN 0002-9149, E-ISSN 1879-1913, Vol. 104, no 11, 1561-1567 p.Article in journal (Refereed) Published
Abstract [en]

We compared the measurements of the aortic valve area (AVA) using dual-source computed tomography (DSCT) in patients with mid to severe aortic stenosis to measurements using transthoracic echocardiography (TTE) and invasive hemodynamic assessment. A total of 50 patients (mean age 73 ± 10 years) with suspected aortic stenosis were included. The computed tomographic data were acquired using DSCT with standardized scan parameters (2 × 64 × 0.6 mm collimation, 330-ms rotation, 120-kV tube voltage, 560 mA/rot tube current). After injection of 35 ml contrast agent (flow rate 5 ml/s), a targeted volume data set, ranging from the top of the leaflets to the infundibulum, was acquired. Ten cross-sectional data sets (slice thickness 1 mm, no overlap, increment 0.6 mm) were reconstructed during systole in 5% increments of the R-R interval. The AVA determined in systole by planimetry was compared to the calculated AVA values using the continuity equation on TTE and the Gorlin formula on catheterization. DSCT allowed the planimetry of the AVA in all patients. The mean AVA using DSCT was 1.16 ± 0.47 cm2 compared to a mean AVA of 1.04 ± 0.45 cm2 using TTE and 1.06 ± 0.45 cm2 using catheterization, with a significant correlation between DSCT/TTE (r = 0.93, p <0.001) and DSCT/cardiac catheterization (r = 0.97, p <0.001). However, DSCT demonstrated a slight, but significant, overestimation of the AVA compared to TTE (+0.12 ± 0.17 cm) and catheterization (+0.10 ± 0.12 cm2). In conclusion, DSCT permits one to assess the AVA with a high-image quality and diagnostic accuracy compared to TTE and invasive determination.

Place, publisher, year, edition, pages
2009. Vol. 104, no 11, 1561-1567 p.
National Category
Medical and Health Sciences
Research subject
URN: urn:nbn:se:uu:diva-196732DOI: 10.1016/j.amjcard.2009.07.024PubMedID: 19932793OAI: oai:DiVA.org:uu-196732DiVA: diva2:610925
Available from: 2013-03-13 Created: 2013-03-13 Last updated: 2013-03-13Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Flachskampf, Frank A
By organisation
In the same journal
American Journal of Cardiology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 159 hits
ReferencesLink to record
Permanent link

Direct link