In vitro measurements of precision of fit of implant-supported frameworks: A comparison between "virtual" and "physical" assessments of fit using two different techniques of measurements
The Mälar Hospital, Eskilstuna, Sweden.
2012 (English)In: Clinical Implant Dentistry and Related Research, ISSN 1523-0899, E-ISSN 1708-8208, Vol. 14, no Suppl 1, e175-e182 p.Article in journal (Refereed) Published
Abstract [en]


Comparisons between different techniques measuring fit of implant-supported frameworks are few.


The purpose of this study was to compare data on precision of fit from two highly accurate measuring techniques and, also, to compare results using software programs for fit assessments considering both a “virtual” as well as a “physical” (i.e., more clinical) situation.

Materials and Methods:

Five computer numerical control-milled titanium frameworks (Procera® Implant Bridge, Nobel Biocare AB, Göteborg, Sweden) were fabricated from individual model/pattern measurements, simulating a clinical situation. Measurements of fit between frameworks and models were performed by means of a coordinate measuring machine (CMM; Zeiss Prismo Vast, Carl Zeiss Industrielle Messtechnik GmbH, Oberkochen, Germany) linked to a computer and an optical, high-resolution, three-dimensional scanner (Atos 4M SO, GOM International AG, Widen, Switzerland). Collected data on distortions between frameworks and models were analyzed and compared between the two measurement techniques. A comparison between “virtual” and “physical” fit assessments was also performed, based on data from the three-dimensional scanner.


When using “virtual” fit assessment programs, overall mean three-dimensional distortion between implant and framework center points in absolute figures was 37 (SD 22) and 14 µm (SD 8) for the CMM and three-dimensional scanning measurements, respectively. Corresponding mean three-dimensional distortion when using a “physical” fit assessment program in the scanner was 43 µm (SD 24) (p < 0.001). Mean horizontal (x-axis) measurements of the distance between the two terminal implants of the models and the frameworks were 33.772 and 33.834 mm for the CMM technique. Corresponding measurements for the three-dimensional scanner was 33.798 and 33.806 mm, respectively. Horizontal distances from the three-dimensional scanner were, for most measurements, greater than for the CMM measurements.


Measurements of fit between frameworks and models may vary depending on what technique is used and how fit assessments regarding “virtual” or “physical” fit is approached.

Place, publisher, year, edition, pages
2012. Vol. 14, no Suppl 1, e175-e182 p.
National Category
Medical and Health Sciences
URN: urn:nbn:se:uu:diva-197767DOI: 10.1111/j.1708-8208.2011.00416.xPubMedID: 22171700OAI: oai:DiVA.org:uu-197767DiVA: diva2:614058
Available from: 2013-04-03 Created: 2013-04-03 Last updated: 2013-04-03Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed
In the same journal
Clinical Implant Dentistry and Related Research
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

Altmetric score

Total: 102 hits
ReferencesLink to record
Permanent link

Direct link