Real-time audiovisual feedback system in a physician-staffed helicopter emergency medical service in Finland: the quality results and barriers to implementation
Show others and affiliations
2013 (English)In: Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine, ISSN 1757-7241, E-ISSN 1757-7241, Vol. 21, 50- p.Article in journal (Refereed) Published
Abstract [en]

Objectives: To evaluate the quality of cardiopulmonary resuscitation (CPR) in a physician staffed helicopter emergency medical service (HEMS) using a monitor-defibrillator with a quality analysis feature. As a post hoc analysis, the potential barriers to implementation were surveyed. Methods: The quality of CPR performed by the HEMS from November 2008 to April 2010 was analysed. To evaluate the implementation rate of quality analysis, the HEMS database was screened for all cardiac arrest missions during the study period. As a consequence of the observed low implementation rate, a survey was sent to physicians working in the HEMS to evaluate the possible reasons for not utilizing the automated quality analysis feature. Results: During the study period, the quality analysis was used for 52 out of 187 patients (28%). In these cases the mean compression depth was < 40 mm in 46% and < 50 mm in 96% of the 1-min analysis intervals, but otherwise CPR quality corresponded with the 2005 resuscitation guidelines. In particular, the no-flow fraction was remarkably low 0.10 (0.07, 0.16). The most common reasons for not using quality-controlled CPR were that the device itself was not taken to the scene, or not applied to the patient, because another EMS unit was already treating the patient with another defibrillator. Conclusions: When quality-controlled CPR technology was used, the indicators of good quality CPR as described in the 2005 resuscitation guidelines were mostly achieved albeit with sufficient compression depth. The use of the well-described technology in improving patient care was low. Wider implementation of the automated quality control and feedback feature in defibrillators could further improve the quality of CPR on the field.

Place, publisher, year, edition, pages
2013. Vol. 21, 50- p.
Keyword [en]
CPR, Quality, Resuscitation, Cardiac arrest, Pre-hospital, HEMS
National Category
Clinical Medicine
Identifiers
URN: urn:nbn:se:uu:diva-204795DOI: 10.1186/1757-7241-21-50ISI: 000321313400001OAI: oai:DiVA.org:uu-204795DiVA: diva2:641080
Available from: 2013-08-15 Created: 2013-08-12 Last updated: 2017-12-06Bibliographically approved

Open Access in DiVA

fulltext(292 kB)123 downloads
File information
File name FULLTEXT01.pdfFile size 292 kBChecksum SHA-512
fd04e1db9b5881513fa12cc185ced03741efe49dac968917a25501535d6037ebb515e31e82ac02000bdcdb51e6000ca776e318221470b2ecc6e7b7e550a9edf8
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Authority records BETA

Tenhunen, Jyrki

Search in DiVA

By author/editor
Tenhunen, Jyrki
By organisation
Anaesthesiology and Intensive Care
In the same journal
Scandinavian Journal of Trauma, Resuscitation and Emergency Medicine
Clinical Medicine

Search outside of DiVA

GoogleGoogle Scholar
Total: 123 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 586 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf