Enumeration of feline platelets in ethylenediamine tetra-acetic acid anticoagulated blood with the ADVIA 2120 system and two manual methods: Leucoplate and Thrombo-TIC
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Sciences, Biomedical Informatics and Engineering.
2013 (English)In: Journal of Veterinary Diagnostic Investigation, ISSN 1040-6387, Vol. 25, no 4, 493-497 p.Article in journal (Refereed) Published
Abstract [en]

A manual method (Thrombo-TIC; Bioanalytic GmbH, Umkirch/Freiburg, Germany) was advertised to disaggregate platelet clumps and to make human platelets spherical to improve platelet enumeration. The current study's hypothesis was that this method would perform better than current methods for feline blood anticoagulated with ethylenediamine tetra-acetic acid (EDTA), which often contains platelet aggregates. Platelet concentrations (PLTs) were determined in 21 feline blood samples by 3 methods. Thrombo-TIC was compared to the manual method (Leucoplate; Sobioda, Montbonnot-Saint-Martin, France) currently used in the authors' laboratory along with an ADVIA 2120 (Siemens AG, Eschborn, Germany) optical platelet concentration. Feline blood samples often contained platelet aggregates. ADVIA flagged for platelet aggregates in 11 of the 21 feline blood samples, and examination of blood smear revealed platelet aggregates in 14 of the 21 samples. The hemocytometers displayed more platelet aggregates with the Thrombo-TIC method than with Leucoplate. The method giving the greatest PLT was considered most accurate. The Leucoplate median PLT (238 x 10(9)/1) was greater than Thrombo-TIC (202 x 10(9)/1) or ADVIA (157 x 10(9)/1). Intra-assay precision was determined for the 3 methods using the 21 feline blood samples. Median Thrombo-TIC and Leucoplate precision (7.4% and 7.3% coefficient of variation [CV], respectively) were similar and not much worse than ADVIA (5.9% CV). The Thrombo-TIC method did not appear to perform better than the current manual method (Leucoplate). Leucoplate appeared least affected by platelet aggregation in feline blood. The ADVIA automated PLT appeared to be most negatively affected by platelet aggregation. The Thrombo-TIC method did not appear to prevent platelet aggregation in feline EDTA blood samples and, thus, is not recommended for such use.

Place, publisher, year, edition, pages
2013. Vol. 25, no 4, 493-497 p.
Keyword [en]
Cats, platelet aggregate, platelet concentration
National Category
Veterinary Science Medical and Health Sciences
URN: urn:nbn:se:uu:diva-211911DOI: 10.1177/1040638713493419ISI: 000326512000006OAI: oai:DiVA.org:uu-211911DiVA: diva2:669192
Available from: 2013-12-03 Created: 2013-12-03 Last updated: 2013-12-03Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text
By organisation
Biomedical Informatics and Engineering
In the same journal
Journal of Veterinary Diagnostic Investigation
Veterinary ScienceMedical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 171 hits
ReferencesLink to record
Permanent link

Direct link