BRANDDIMENSIONERING AV STÅL: En jämförelse av dimensioneringsmetoder
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Applied Mechanics, Byggteknik.
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Applied Mechanics, Byggteknik.
2014 (Swedish)Independent thesis Basic level (professional degree), 10 credits / 15 HE creditsStudent thesisAlternative title
FIRE DESIGN OF STEEL : A comparison of design methods (English)
Abstract [sv]

När byggbranschen för några år sedan fasade ut de tidigare nationella regelverken och ersatte dem med de gemensamma europeiska konstruktionsstandarderna, Eurokoderna, ändrades processen för att brandskydda konstruktioner. Hur dimensionerings­processen ser ut med de nya reglerna är inte helt enkelt att sätta sig in i. Därmed har detta examensarbete framställts på uppdrag av Sweco Structures AB.

Huvudmomentet i arbetet är beskrivning och förklaring av de befintliga dimensioneringsmetoderna. För att förstå metoderna från regelverken består de första kapitlen i detta arbete av grundläggande teori för brandens verkningssätt och stålets respons vid förhöjd temperatur. Detta följs av en genomgång av de förenklade beräkningsmetoderna och dess ekvationer. I rapporten ingår även en fallstudie där en stålkomponent i en industribyggnad analyseras.

Resultat från fallstudien visar att den så kallade kritiska temperaturmetoden inte bör användas för konstruktioner där instabilitetsfenomen måste beaktas. Den kritiska temperaturmetoden har därför ett mycket begränsat användningsområde. Det visade sig även att kostnaderna för att öka diagonalens dimensioner uppgick till ungefär samma kostnad som att brandskyddsmåla. Detta är dock mycket beroende på situation och sannolikt varierar kostnaderna kraftigt. 

Abstract [en]

When the construction industry phased out the earlier national construction standards a few years ago and replaced them with the European standards, the rules for fire safety changed. The new design process is complex and not simple to get a full picture of. For that purpose this thesis is written for Sweco Structures AB.

The main part of this thesis comprises of descriptions and explanations of the existing design methodologies. To better understand the methods in Eurocode, the first chapter contains basic theory of how fires behave and how steel responds to higher temperatures. The following chapters address the simplified calculation methods and their equations. The report also includes a case study of a steel framed industrial building where a critical diagonal was analyzed.

The analysis showed that the method called critical temperature method is not applicable for components where instability is taken into account. Those components should instead be calculated using the equations given in Eurocode. Therefore the critical temperature method has a very limited use. The analysis also showed that the cost of increasing the dimension of the diagonal was about the same as the cost of coating it with fire resisting paint, but this is very dependent on the situation. The report concludes with discussion and comparison of results.

Place, publisher, year, edition, pages
2014.
Keyword [sv]
Brand, Stål, Stålkonstruktioner, Brandskydd, Brandskyddsdimensionering, Industri.
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:uu:diva-226142ISRN: UTH-INGUTB-EX-B-2014/18-SEOAI: oai:DiVA.org:uu-226142DiVA: diva2:724234
External cooperation
Alexander Dobo, Sweco Structures AB
Educational program
Bachelor Programme in Construction Engineering
Presentation
2014-06-03, Ångströmslaboratoriet, Siegbahnsalen, Lägerhyddsvägen 1, Uppsala, 17:20 (Swedish)
Supervisors
Examiners
Available from: 2014-06-12 Created: 2014-06-12 Last updated: 2014-06-12Bibliographically approved

Open Access in DiVA

Branddimensionering_av_stål(4946 kB)540 downloads
File information
File name FULLTEXT01.pdfFile size 4946 kBChecksum SHA-512
b69410e38d9855dda43a91083151eefb74a30f2bee21c9aa73ba5b3d5de6d74013632a03d6a7402fa22a3ffe432434e9e298b4095447a15af8aa263a99d1a7a6
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
El Mourabit, SamirForsberg, Mattias
By organisation
Byggteknik
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 540 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1317 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf