Analys av mätdata från nätstationer
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity.
2014 (Swedish)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesisAlternative title
Analysis of data from secondary substations (English)
Abstract [en]

Fortum has in a pilot project installed metering equipment with wireless communication in secondary substations in Stockholm. So far, the collected data are used only in specific projects.

This master thesis was carried out at Fortum Distribution AB in Stockholm during 2013. The purpose of this study is to simplify and enhance the use of data in for example network planning process, by giving suggestions on how data can be managed and giving examples of analyzes that collected data can be used for.

The electricity meter which Fortum has installed is a EDMI-Mk10A which is set to measure max/average/min values with a one hour time resolution of the following parameters: voltage (per phase), current (per phase) andactive power and active and reactive energy.

In order to analyze the collected data an analysis tool is required. During this thesis two customized tools in Microsoft Excel have been developed, one for sorting data and one for analyzing.

One aim of the thesis is to show examples of what collected measurement data can be used for. This work shows an example of analysis of active power, power factor, voltage, occurrence of interrupts and the relationship between outdoor temperature and power.

This master thesis has among others resulted in the following advice: Expand the number of secondary substations with measuring equipment. Higher time resolution. Measure apparent power and temperature.

Place, publisher, year, edition, pages
2014. , 63 p.
Series
UPTEC ES, ISSN 1650-8300 ; 14005
Keyword [sv]
Fortum, mätdata, nätstation
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:uu:diva-226664OAI: oai:DiVA.org:uu-226664DiVA: diva2:728790
External cooperation
Fortum Distribution AB
Educational program
Master Programme in Energy Systems Engineering
Presentation
2014-01-31, 13:15 (Swedish)
Supervisors
Examiners
Available from: 2014-06-26 Created: 2014-06-18 Last updated: 2014-06-26Bibliographically approved

Open Access in DiVA

fulltext(1346 kB)388 downloads
File information
File name FULLTEXT01.pdfFile size 1346 kBChecksum SHA-512
09618f4034baf55f5d45aae75de951c16b0faf8073982fa8996652dd0796910617d9685154a1dddc5302f839d086771d9e3dd864d3138661c9326e2a9a2538a1
Type fulltextMimetype application/pdf

By organisation
Electricity
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 388 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1279 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf