uu.seUppsala University Publications
Change search
ReferencesLink to record
Permanent link

Direct link
Quantitative Assessment of Myocardial Perfusion in the Detection of Significant Coronary Artery Disease Cutoff Values and Diagnostic Accuracy of Quantitative [O-15]H2O PET Imaging
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Radiology, Oncology and Radiation Science, Section of Nuclear Medicine and PET.
Show others and affiliations
2014 (English)In: Journal of the American College of Cardiology, ISSN 0735-1097, E-ISSN 1558-3597, Vol. 64, no 14, 1464-1475 p.Article in journal (Refereed) Published
Abstract [en]

BACKGROUND Recent studies have demonstrated improved diagnostic accuracy for detecting coronary artery disease (CAD) when myocardial blood flow (MBF) is quantified in absolute terms, but there are no uniformly accepted cutoff values for hemodynamically significant CAD. OBJECTIVES The goal of this study was to determine cutoff values for absolute MBF and to evaluate the diagnostic accuracy of quantitative [O-15]H2O positron emission tomography (PET). METHODS A total of 330 patients underwent both quantitative [O-15]H2O PET imaging and invasive coronary angiography in conjunction with fractional flow reserve measurements. A stenosis >90% and/or fractional flow reserve <= 0.80 was considered obstructive; a stenosis <30% and/or fractional flow reserve >0.80 was nonobstructive. RESULTS Hemodynamically significant CAD was diagnosed in 116 (41%) of 281 patients who fulfilled study criteria for CAD. Resting perfusion was 1.00 +/- 0.25 and 0.92 +/- 0.23 ml/min/g in regions supplied by nonstenotic and significantly stenosed vessels, respectively (p < 0.001). During stress, perfusion increased to 3.26 +/- 1.04 ml/min/g and 1.73 +/- 0.67 ml/min/g, respectively (p < 0.001). The optimal cutoff values were 2.3 and 2.5 for hyperemic MBF and myocardial flow reserve, respectively. For MBF, these cutoff values showed a sensitivity, specificity, and accuracy for detecting significant CAD of 89%, 84%, and 86%, respectively, at a per-patient level and 87%, 85%, and 85% at a per-vessel level. The corresponding myocardial flow reserve values were 86%, 72%, and 78% (per patient) and 80%, 82%, and 81% (per vessel). Age and sex significantly affected diagnostic accuracy of quantitative PET. CONCLUSIONS Quantitative MBF measurements with the use of [O-15]H2O PET provided high diagnostic performance, but both sex and age should be taken into account.

Place, publisher, year, edition, pages
2014. Vol. 64, no 14, 1464-1475 p.
Keyword [en]
myocardial blood flow, myocardial flow reserve, receiver-operator characteristic curve, sensitivity, specificity
National Category
Cardiac and Cardiovascular Systems
URN: urn:nbn:se:uu:diva-237311DOI: 10.1016/j.jacc.2014.05.069ISI: 000343464800011PubMedID: 25277618OAI: oai:DiVA.org:uu-237311DiVA: diva2:767578
Available from: 2014-12-01 Created: 2014-12-01 Last updated: 2014-12-01Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Kero, TanjaJames, Stefan K.Sörensen, Jens
By organisation
Section of Nuclear Medicine and PETCardiologyUCR-Uppsala Clinical Research CenterClinical Physiology
In the same journal
Journal of the American College of Cardiology
Cardiac and Cardiovascular Systems

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 178 hits
ReferencesLink to record
Permanent link

Direct link