A randomized, prospective, intercontinental evaluation of a bioresorbable polymer sirolimus-eluting coronary stent system: the CENTURY II (Clinical Evaluation of New Terumo Drug-Eluting Coronary Stent System in the Treatment of Patients with Coronary Artery Disease) trial
Show others and affiliations
2014 (English)In: European Heart Journal, ISSN 0195-668X, E-ISSN 1522-9645, Vol. 35, no 30, 2021-2031 p.Article in journal (Refereed) Published
Abstract [en]

Aim The aim of this study was to establish safety and efficacy of a new sirolimus-eluting stent with bioresorbable polymer, Ultimaster (BP-SES). Sirolimus-eluting stent with bioresorbable polymer was compared with everolimus-eluting, permanent polymer, Xience stent (PP-EES) in the frame of a CENTURY II clinical trial designed to make global clinical data compliant with regulatory requirements in Europe and Japan.

Methods and results The CENTURY II is a prospective, multicentre, randomized (1 : 1), single blind, controlled, non-inferiority clinical trial conducted at 58 study sites in Japan, Europe, and Korea. A total of 1123 patients requiring a percutaneous coronary intervention (PCI) procedure, with implantation of drug-eluting stent (DES), were enrolled [total population (TP)]. Randomization of patients was stratified for the subset of patients matching requirements for DES in Japan (Cohort JR, n = 722). Baseline patient demographic and angiographic characteristics were similar in both study arms, with minimal differences between the TP and Cohort JR. The primary endpoint, freedom from target lesion failure (TLF) at 9 months—TLF [composite of cardiac death, target-vessel-related myocardial infarction (MI) and target lesion revascularization]—was 95.6% with BP-SES and 95.1% with PP-EES (Pnon-inferiority<0.0001). Composite of cardiac death and MI rate was 2.9 and 3.8% (P = 0.40) and target vessel revascularization was 4.5% with BP-SES and 4.2% with PP-EES (P = 0.77). The stent thrombosis rate was 0.9% in both arms. In Cohort JR, freedom from TLF was 95.9 and 94.6% (Pnon-inferiority < 0.0005) with BP-SES and PP-EES, respectively.

Conclusion The new bioresorbable polymer sirolimus-eluting stent showed safety and efficacy profiles similar to durable polymer everolimus-eluting stent at 9-month follow-up.

Place, publisher, year, edition, pages
2014. Vol. 35, no 30, 2021-2031 p.
National Category
Cardiac and Cardiovascular Systems
Identifiers
URN: urn:nbn:se:uu:diva-245852DOI: 10.1093/eurheartj/ehu210OAI: oai:DiVA.org:uu-245852DiVA: diva2:791604
Available from: 2015-03-01 Created: 2015-03-01 Last updated: 2017-12-04Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full text

Authority records BETA

James, Stefan

Search in DiVA

By author/editor
James, Stefan
By organisation
Cardiology
In the same journal
European Heart Journal
Cardiac and Cardiovascular Systems

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 331 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf