uu.seUppsala University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Fretting behaviour of silicon nitride against biomedical alloys for joint replacements
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Applied Materials Sciences.
Institute of Functional Surfaces (iFS), School of Mechanical Engineering, University of Leeds.
Institute of Functional Surfaces (iFS), School of Mechanical Engineering, University of Leeds.
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Applied Materials Sciences.
Show others and affiliations
(English)Manuscript (preprint) (Other academic)
Keyword [en]
fretting, corrosion, Si3N4, CoCr, Ti-6Al-4V, total joint replacements, CoM, taper, biotribology, hip
National Category
Materials Engineering Medical Materials
Research subject
Engineering Science with specialization in Materials Science
Identifiers
URN: urn:nbn:se:uu:diva-247795OAI: oai:DiVA.org:uu-247795DiVA: diva2:797478
Funder
EU, FP7, Seventh Framework Programme, 310477
Available from: 2015-03-24 Created: 2015-03-24 Last updated: 2015-07-07
In thesis
1. Silicon nitride for total hip replacements
Open this publication in new window or tab >>Silicon nitride for total hip replacements
2015 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

For more than 50 years total hip replacements have been a common and successful procedure to increase patient mobility and quality of life. The 10-year implant survival rate is 97.8%. However, for longer implantation times there are limitations linked to the negative biological response to wear and corrosion products from the currently used biomaterials.

In this thesis silicon nitride (SiNx) coatings were evaluated for use in total hip replacements, on the articulating bearing surface and modular taper connections. Homogeneous, dense SiNx coatings were deposited using reactive high power impulse magnetron sputtering (HiPIMS) up to a thickness of 8 µm. The N/Si atomic ratios ranged from 0.3 to 1.1 and the coatings showed a low surface roughness. The wear rate of a SiNx coated cobalt chromium molybdenum alloy (CoCrMo) was similar to that of bulk Si3N4, and less than one 46th of uncoated CoCrMo, an alloy that is commonly used in joint replacements. Wear debris generated from SiNx coatings was round in shape, with a mean size of 40 nm, and ranged between 10 and 500 nm. Model particles, similar in size and shape as the wear debris, were soluble in simulated body fluid. The dissolution rate was higher than the expected rate of debris generation. Along with the size of the debris, which is not in the critical range for macrophage activation, this dissolution may limit negative biological reactions. The SiNx coatings also dissolved in simulated body fluid. The coating with the highest N/Si ratio exhibited the lowest dissolution rate, of 0.2 to 0.4 nm/day, while CoCrMo under the same condition dissolved at a rate of 0.7 to 1.2 nm/day. SiNx-coated CoCrMo exhibited a reduced release of Co, Cr and Mo ions into the solution by two orders of magnitude, compared to uncoated CoCrMo. Si3N4 evaluated under micro-displacement in a corrosive environment, replicating the modular taper, showed a lower corrosion current compared to common biomedical alloys. SiNx coatings may also act beneficially to reduce issues associated with this type of contact.

SiNx coatings have shown several properties in a laboratory environment that are hypothesised to increase the longevity of joint replacements. The promising results encourage further evaluation closer to the clinical application of total hip replacements, in particular in the articulating bearing surface and in modular tapers.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2015. 53 p.
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1242
Keyword
SiNx, Si3N4, coatings, CoCr, Ti, alloy, tribology, wear, corrosion, dissolution, debris, hip, arthroplasty
National Category
Materials Engineering Medical Materials
Research subject
Engineering Science with specialization in Materials Science
Identifiers
urn:nbn:se:uu:diva-247800 (URN)978-91-554-9211-3 (ISBN)
Public defence
2015-05-22, Häggsalen, Ångströmslaboratoriet, Lägerhyddsvägen 1, Uppsala, 13:30 (English)
Opponent
Supervisors
Funder
Swedish Foundation for Strategic Research EU, FP7, Seventh Framework Programme, 310477
Available from: 2015-04-29 Created: 2015-03-24 Last updated: 2015-07-07

Open Access in DiVA

No full text

Authority records BETA

Pettersson, MariaEngqvist, HåkanPersson, Cecilia

Search in DiVA

By author/editor
Pettersson, MariaEngqvist, HåkanPersson, Cecilia
By organisation
Applied Materials Sciences
Materials EngineeringMedical Materials

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 964 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf