Assessing Improvement in Detection of Breast Cancer with Three-dimensional Automated Breast US in Women with Dense Breast Tissue: The Somoinsight Study
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Medical Sciences.
Show others and affiliations
2015 (English)In: Radiology, ISSN 0033-8419, E-ISSN 1527-1315, Vol. 274, no 3, 663-673 p.Article in journal (Refereed) Published
Abstract [en]

Purpose: To determine improvement in breast cancer detection by using supplemental three-dimensional (3D) automated breast (AB) ultrasonography (US) with screening mammography versus screening mammography alone in asymptomatic women with dense breasts. Materials and Methods: Institutional review board approval and written informed consent were obtained for this HIPAA-compliant study. The SomoInsight Study was an observational, multicenter study conducted between 2009 and 2011. A total of 15 318 women (mean age, 53.3 years +/- 10 [standard deviation]; range, 2594 years) presenting for screening mammography alone with heterogeneously (50%75%) or extremely (>75%) dense breasts were included, regardless of further risk characterization, and were followed up for 1 year. Participants underwent screening mammography alone followed by an AB US examination; results were interpreted sequentially. McNemar test was used to assess differences in cancer detection. Results: Breast cancer was diagnosed at screening in 112 women: 82 with screening mammography and an additional 30 with AB US. Addition of AB US to screening mammography yielded an additional 1.9 detected cancers per 1000 women screened (95% confidence interval [CI]: 1.2, 2.7; P < .001). Of cancers detected with screening mammography, 62.2% (51 of 82) were invasive versus 93.3% (28 of 30) of additional cancers detected with AB US (P = .001). Of the 82 cancers detected with either screening mammography alone or the combined read, 17 were detected with screening mammography alone. Of these, 64.7% (11 of 17) were ductal carcinoma in situ versus 6.7% (two of 30) of cancers detected with AB US alone. Sensitivity for the combined read increased by 26.7% (95% CI: 18.3%, 35.1%); the increase in the recall rate per 1000 women screened was 284.9 (95% CI: 278.0, 292.2; P < .001). Conclusion: Addition of AB US to screening mammography in a generalizable cohort of women with dense breasts increased the cancer detection yield of clinically important cancers, but it also increased the number of false-positive results. (C)RNSA, 2014.

Place, publisher, year, edition, pages
2015. Vol. 274, no 3, 663-673 p.
National Category
Radiology, Nuclear Medicine and Medical Imaging
URN: urn:nbn:se:uu:diva-248445DOI: 10.1148/radiol.14132832ISI: 000349990500005PubMedID: 25329763OAI: oai:DiVA.org:uu-248445DiVA: diva2:800286
Available from: 2015-04-02 Created: 2015-03-30 Last updated: 2015-04-02Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed
By organisation
Department of Medical Sciences
In the same journal
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Altmetric score

Total: 147 hits
ReferencesLink to record
Permanent link

Direct link