A Comparison of Wind Power Production with Three Different De- and Anti-Icing Systems
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity.
2015 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

This thesis is done within the master program in energy systems engineering at Uppsala University and in cooperation with OX2. The aim was to compare the operation and performance of three different de- and anti-icing systems for wind turbines during the winter 2014/2015. The systems evaluated were de-icing with heating resistances, de-icing with warm air and anti-icing with heating resistances.

Inconsistency in the operation of the wind turbines and the systems as well as lack of information made it hard to compare the efficiencies of the systems. The systems showed tendencies to improve the production. Especially examples during single ice events where the systems increased the power output were found, but the examples also showed possible improvements regarding the size of the systems and the duration of the de-or anti-icing cycles. Based on the approximated gain in production, during the studied time period, none of the systems could be determined to be profitable. The gain in production does however not have to be especially large for the systems to become profitable, and the results could be very different in a year with more ice, higher electricity prices or a more consistent operation of the systems.

Important characteristics of the systems were found to be the duration of a cycle, the energy required for the operation of the system and the trigger-point for activation of the system. Additional benefits like for instance decreased loads, risk for standstill and ice throws could also be provided by the system.

Place, publisher, year, edition, pages
2015. , 58 p.
Series
UPTEC ES, ISSN 1650-8300 ; 15018
Keyword [en]
wind turbine, de-icing, anti-icing, ice, losses
Keyword [sv]
vindkraftverk, avisning, is, förluster
National Category
Energy Systems
Identifiers
URN: urn:nbn:se:uu:diva-254966OAI: oai:DiVA.org:uu-254966DiVA: diva2:820503
External cooperation
OX2
Educational program
Master Programme in Energy Systems Engineering
Supervisors
Examiners
Available from: 2015-06-17 Created: 2015-06-12 Last updated: 2015-06-17Bibliographically approved

Open Access in DiVA

fulltext(2276 kB)989 downloads
File information
File name FULLTEXT01.pdfFile size 2276 kBChecksum SHA-512
e4911a53464299bb77bd8bb948f48461c7c5cd2540877958717b23460c3293973041199dbebdd1d450693caf62cb2ee235f2a9e8eb124952008483441ada16e2
Type fulltextMimetype application/pdf

By organisation
Electricity
Energy Systems

Search outside of DiVA

GoogleGoogle Scholar
Total: 989 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1042 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf