uu.seUppsala University Publications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Influence of gas composition on recurrence of atelectasis after a reexpansion maneuver during general anaesthesia
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Anaesthesiology and Intensive Care.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Anaesthesiology and Intensive Care.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Anaesthesiology and Intensive Care.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Radiology, Oncology and Radiation Science, Radiology.
Show others and affiliations
1995 (English)In: Anesthesiology, ISSN 0003-3022, E-ISSN 1528-1175, Vol. 82, no 4, 832-842 p.Article in journal (Refereed) Published
Abstract [en]

BACKGROUND:

Atelectasis, an important cause of impaired gas exchange during general anesthesia, may be eliminated by a vital capacity maneuver. However, it is not clear whether such a maneuver will have a sustained effect. The aim of this study was to determine the impact of gas composition on reappearance of atelectasis and impairment of gas exchange after a vital capacity maneuver.

METHODS:

A consecutive sample of 12 adults with healthy lungs who were scheduled for elective surgery were studied. Thirty minutes after induction of anesthesia with fentanyl and propofol, the lungs were hyperinflated manually up to an airway pressure of 40 cmH2O. FIO2 was either kept at 0.4 (group 1, n = 6) or changed to 1.0 (group 2, n = 6) during the recruitment maneuver. Atelectasis was assessed by computed tomography. The amount of dense areas was measured at end-expiration in a transverse plane at the base of the lungs. The ventilation-perfusion distributions (VA/Q) were estimated with the multiple inert gas elimination technique. The static compliance of the total respiratory system (Crs) was measured with the flow interruption technique.

RESULTS:

In group 1 (FIO2 = 0.4), the recruitment maneuver virtually eliminated atelectasis for at least 40 min, reduced shunt (VA/Q < 0.005), and increased at the same time the relative perfusion to poorly ventilated lung units (0.005 < VA/Q < 0.1; mean values are given). The arterial oxygen tension (PaO2) increased from 137 mmHg (18.3 kPa) to 163 mmHg (21.7 kPa; before and 40 min after recruitment, respectively; P = 0.028). In contrast to these findings, atelectasis recurred within 5 min after recruitment in group 2 (FIO2 = 1.0). Comparing the values before and 40 min after recruitment, all parameters of VA/Q were unchanged. In both groups, Crs increased from 57.1/55.0 ml.cmH2O-1 (group 1/group 2) before to 70.1/67.4 ml.cmH2O-1 after the recruitment maneuver. Crs showed a slow decrease thereafter (40 min after recruitment: 61.4/60.0 ml.cmH2O-1), with no difference between the two groups.

CONCLUSIONS:

The composition of inspiratory gas plays an important role in the recurrence of collapse of previously reexpanded atelectatic lung tissue during general anesthesia in patients with healthy lungs. The reason for the instability of these lung units remains to be established. The change in the amount of atelectasis and shunt appears to be independent of the change in the compliance of the respiratory system.

Place, publisher, year, edition, pages
1995. Vol. 82, no 4, 832-842 p.
National Category
Medical and Health Sciences
Identifiers
URN: urn:nbn:se:uu:diva-54383PubMedID: 7717553OAI: oai:DiVA.org:uu-54383DiVA: diva2:82292
Available from: 2008-10-17 Created: 2008-10-17 Last updated: 2017-12-04Bibliographically approved

Open Access in DiVA

No full text

PubMed

Authority records BETA

Wegenius, GöranHögman, MarieannHedenstierna, Göran

Search in DiVA

By author/editor
Wegenius, GöranHögman, MarieannHedenstierna, Göran
By organisation
Anaesthesiology and Intensive CareRadiologyClinical Physiology
In the same journal
Anesthesiology
Medical and Health Sciences

Search outside of DiVA

GoogleGoogle Scholar

pubmed
urn-nbn

Altmetric score

pubmed
urn-nbn
Total: 354 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf