Variability of the pullout strength of cancellous bone screws with cement augmentation
Show others and affiliations
2015 (English)In: Clinical Biomechanics, ISSN 0268-0033, E-ISSN 1879-1271, Vol. 30, no 5, 500-506 p.Article in journal (Refereed) Published
Abstract [en]

Background: Orthopaedic surgeons often face clinical situations where improved screw holding power in cancellous bone is needed. Injectable calcium phosphate cements are one option to enhance fixation. Methods: Paired screw pullout tests were undertaken in which human cadaver bone was augmented with calcium phosphate cement. A finite element model was used to investigate sensitivity to screw positional placement. Findings: Statistical analysis of the data concluded that the pullout strength was generally increased by cement augmentation in the in vitro human cadaver tests. However, when comparing the individual paired samples there were surprising results with lower strength than anticipated after augmentation, in apparent contradiction to the generally expected conclusion. Investigation using the finite element model showed that these strength reductions could be accounted for by small screw positional changes. A change of 0.5 mm might result in predicted pullout force changes of up to 28%. Interpretation: Small changes in screw position might lead to significant changes in pullout strength sufficient to explain the lower than expected individual pullout values in augmented cancellous bone. Consequently whilst the addition of cement at a position of low strength would increase the pullout strength at that point it might not reach the pullout strength of the un-augmented paired test site. However, the overall effect of cement augmentation produces a significant improvement at whatever point in the bone the screw is placed. The use of polymeric bone-substitute materials for tests may not reveal the natural variation encountered in tests using real bone structures.

Place, publisher, year, edition, pages
2015. Vol. 30, no 5, 500-506 p.
Keyword [en]
Cancellous bone, Bone screws, Pullout testing, Human cadaver, Finite element modelling
National Category
Orthopedics
Identifiers
URN: urn:nbn:se:uu:diva-256812DOI: 10.1016/j.clinbiomech.2015.03.003ISI: 000355365900017PubMedID: 25794899OAI: oai:DiVA.org:uu-256812DiVA: diva2:827749
Available from: 2015-06-29 Created: 2015-06-26 Last updated: 2017-12-04Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Authority records BETA

Larsson, Sune

Search in DiVA

By author/editor
Larsson, Sune
By organisation
Orthopaedics
In the same journal
Clinical Biomechanics
Orthopedics

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 414 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf