Frequency Stability of Isolated Hydropower Plant with Surge Tank Under Different Turbine Control Modes
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity. (Hydropower)
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity.
2015 (English)In: Electric power components and systems, ISSN 1532-5008, E-ISSN 1532-5016, Vol. 43, no 15, 1707-1716 p.Article in journal (Refereed) Published
Abstract [en]

Currently, the Thoma criterion is often violated to diminish the cross-section of the surge tank; therefore, the surge fluctuation is aggravated and the frequency stability becomes more deteriorative. The focus of this article is on stabilizing the low-frequency oscillation of an isolated hydropower plant caused by surge fluctuation. From a new perspective of hydropower plant operation mode, frequency stability under power control is investigated and compared with frequency control by adopting the Hurwitz criterion and numerical simulation. In a theoretical derivation, the governor equations of frequency control and power control are introduced to the mathematical model. For numerical simulation, a governor model with a control mode switch-over function is built. The frequency oscillations under frequency control, power control, and control mode switch-over are simulated and investigated, respectively, with different governor parameters and operation cases. The result shows that the power control has a better performance on frequency stability at the expense of rapidity compared with the frequency control. Other recommendations regarding worst operation cases and choice of control modes are also developed.

Place, publisher, year, edition, pages
2015. Vol. 43, no 15, 1707-1716 p.
National Category
Other Engineering and Technologies
Identifiers
URN: urn:nbn:se:uu:diva-260774DOI: 10.1080/15325008.2015.1049722ISI: 000359869100003OAI: oai:DiVA.org:uu-260774DiVA: diva2:848389
Available from: 2015-08-24 Created: 2015-08-24 Last updated: 2017-12-04Bibliographically approved
In thesis
1. Dynamic Processes and Active Power Control of Hydropower Plants
Open this publication in new window or tab >>Dynamic Processes and Active Power Control of Hydropower Plants
2015 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Hydro-electricity plays an important role in the safe, stable and efficient operation of electric power systems. Frequency stability of power systems refers to the ability to maintain steady frequency following a severe system upset resulting in a significant imbalance between generation and load. In order to suppress power grid frequency fluctuations, generating units change their power output automatically according to the change of grid frequency, to make the active power balanced again. This is the primary frequency control (PFC). PFC of electrical power grids is commonly performed by units in hydropower plants (HPPs), because of the great rapidity and amplitude of their power regulation.

A hydropower generation system is a complex nonlinear power system including hydraulic, mechanical, electrical and magnetic subsystems. Nowadays, the size of HPPs and the structure complexity of systems have been increasing, especially in China. The proportion of electricity generated by intermittent renewable energy sources have also been growing. Therefore, the performance of HPPs in terms of frequency control is more and more important. The research on control strategies and dynamic processes of HPPs is of great importance. The frequency stability of hydropower units is a critical factor of power system security and power quality. The power response time for evaluating the frequency regulation quality, is also a key indicator.

In recent years, there is a tendency that the new turbines experience fatigue to a greater extent than what seem to be the case for new runners decades ago, due to more regulation movements caused by increasingly more integration of intermittent renewable energy sources. In some countries, as in Sweden, PFC is a service that the transmission system operator buys from the power producers. In other countries, as in Norway and China, there is also an obligation for the producers to deliver this service, free of charge. However, there are costs related to this, e.g. due to design constraints and auxiliary equipment when purchasing a new unit or system, and due to wear and tear which affects the expected life time and maintenance intervals. Hence the specific research on wear and tear of hydro units due to PFC is exceedingly necessary. 

Place, publisher, year, edition, pages
Uppsala: Institutionen för teknikvetenskaper; Elektricitetslära, 2015. 53 p.
National Category
Engineering and Technology
Research subject
Engineering Science with specialization in Science of Electricity
Identifiers
urn:nbn:se:uu:diva-262768 (URN)
Presentation
2015-10-19, Polhemsalen, Ångströmlaboratoriet (Ång/10134), Lägerhyddsvägen 1, Uppsala, 10:15 (English)
Opponent
Supervisors
Available from: 2015-10-14 Created: 2015-09-20 Last updated: 2015-10-14Bibliographically approved
2. Hydropower plants and power systems: Dynamic processes and control for stable and efficient operation
Open this publication in new window or tab >>Hydropower plants and power systems: Dynamic processes and control for stable and efficient operation
2017 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

As the largest global renewable source, hydropower shoulders a large portion of the regulation duty in many power systems. New challenges are emerging from variable renewable energy (VRE) sources, the increasing scale and complexity of hydropower plants (HPPs) and power grid. Stable and efficient operation of HPPs and their interaction with power systems is of great importance.

Theoretical analysis, numerical simulation and on-site measurement are adopted as main study methods in this thesis. Various numerical models of HPPs are established, with different degrees of complexity for different purposes. The majority of the analysis and results are based on eight HPPs in Sweden and China.

Stable operation (frequency stability and rotor angle stability) and efficient operation are two important goals. Regarding the stable operation, various operating conditions are analysed; the response time of primary frequency control (PFC) and the system stability of isolated operation are investigated. A fundamental study on hydraulic-mechanical-electrical coupling mechanisms for small signal stability of HPPs is conducted. A methodology is proposed to quantify the contribution to the damping of low frequency oscillations from hydraulic turbines. The oscillations, with periods ranging from less than one up to hundreds of seconds, are analysed.

Regarding the efficient operation, a description and an initial analysis of wear and tear of turbines are presented; a controller filter is proposed as a solution for wear reduction of turbines and maintaining the frequency quality of power systems; then the study is further extended by proposing a framework that combines technical plant operation with economic indicators, to obtain relative values of regulation burden and performance of PFC.

The results show that the coupling between the hydraulic-mechanical subsystem and the electrical subsystem can be considerable and should be considered with higher attention. Effectiveness and applicability of different numerical models are shown, supplying suggestions for further model optimization. For the influence from power systems on HPPs, the dynamic processes and corresponding control strategies of HPPs under diverse disturbances and requirements from power systems are addressed. For the influence from HPPs on power systems, quantifications of frequency quality and the hydraulic damping are conducted utilising proposed methodologies.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2017. 140 p.
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1494
National Category
Engineering and Technology
Identifiers
urn:nbn:se:uu:diva-318470 (URN)978-91-554-9871-9 (ISBN)
Public defence
2017-05-19, Polhemsalen, Ångtröm 10134, Lägerhyddsvägen 1, Ångströmlaboratoriet, Uppsala, 13:15 (English)
Opponent
Supervisors
Available from: 2017-04-28 Created: 2017-03-24 Last updated: 2017-05-05

Open Access in DiVA

fulltext(758 kB)54 downloads
File information
File name FULLTEXT02.pdfFile size 758 kBChecksum SHA-512
fda179097a6129238bfc5dbeeba5e474d77a85b363bf91544a2658370693b07be7d7ce0e624cec6415ddbf387ffd446bc46588a4355170be096ea1f3af0950a3
Type fulltextMimetype application/pdf

Other links

Publisher's full text

Authority records BETA

Yang, WeijiaNorrlund, Per

Search in DiVA

By author/editor
Yang, WeijiaNorrlund, Per
By organisation
Electricity
In the same journal
Electric power components and systems
Other Engineering and Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 54 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 434 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf