Improved extraction torque of hydroxyapatite-coated pedicle screws
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Orthopaedics.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Orthopaedics.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Orthopaedics.
2000 (English)In: European spine journal, ISSN 0940-6719, E-ISSN 1432-0932, Vol. 9, no 6, 534-7 p.Article in journal (Refereed) Published
Abstract [en]

Loosening of the screws is a problem in instrumentation with pedicle screws. Coating with hydroxyapatite improves the holding characteristics for metal implants, but the possible effects on the anchorage of pedicle screws have not been described. In this study, seven patients were operated on with spinal instrumentation using four stainless steel pedicle screws. Hydroxyapatite-coated screws were used in either the upper or the lower of the instrumented levels. The insertion torque was measured. In four cases the screws were removed after 10-22 months and the extraction torque was measured. The mean insertion torque was found to be significantly greater in the hydroxyapatite-coated screws (107 Ncm) than in the standard screws (76 Ncm). In three cases, the extraction torque for the hydroxyapatite-coated screws exceeded the range for the torque wrench (600 Ncm), while the conventional screws were loose (< 5 Ncm). In one case, the extraction torque was 475 and 550 Ncm for the coated screws, and 5 and 25 Ncm for the conventional screws. The difference in extraction torque was significant. Hydroxyapatite coating was shown to have improved the purchase of pedicle screws very effectively. By using fully coated screws, as in the present study, extraction was extremely difficult compared to extraction of conventional stainless steel screws, which were regularly loose. By reducing the area of the screws that is coated, it may be possible to achieve an enhanced purchase while extraction will be easier when compared to fully coated screws.

Place, publisher, year, edition, pages
2000. Vol. 9, no 6, 534-7 p.
National Category
Surgery
Research subject
Orthopaedics
Identifiers
URN: urn:nbn:se:uu:diva-58366DOI: 10.1007/s005860000180PubMedID: 11189923OAI: oai:DiVA.org:uu-58366DiVA: diva2:86276
Available from: 2008-10-17 Created: 2008-10-17 Last updated: 2017-12-01Bibliographically approved

Open Access in DiVA

No full text

Other links

Publisher's full textPubMed

Authority records BETA

Olerud, ClaesLarsson, Sune

Search in DiVA

By author/editor
Olerud, ClaesLarsson, Sune
By organisation
Orthopaedics
In the same journal
European spine journal
Surgery

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 325 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf