Determination of flumazenil in human plasma by liquid chromatography - electrospray ionisation tandem mass spectrometry
Uppsala University, Teknisk-naturvetenskapliga vetenskapsområdet, Chemistry, Department of Chemistry. Analytisk kemi.
Show others and affiliations
2004 (English)In: Journal of Chromatography B, no 808, 221-227 p.Article in journal (Refereed) Published
Abstract [en]

A liquid chromatography-electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS) method was developed to determine unlabelled flumazenil (Ro 15-1788) in human plasma in (11 C)flumazenil positron emission tomagraphy (PET) studies.

N-Methyl tri-deuterated flumazenil was used as an internal standard. The analyte and internal standard were extracted from plasma samples using solid-phase extraction, with a recovery of 78%. This was determined through the convenience of radioactivity measurements of 11 C-labelled flumazenil. The evaporated and reconstituted eluate was analysed by LC-ESI-MS/MS. The calibration curve was linear over the tested concentration range of 0.05-0.5 nM (15-150 pg/ml) with a correlation coefficient, R 2, of 0.998 +- 0.001. A high precision was achieved, with mean intra-assay and inter-assay relative standard deviations of at most 6 and 7%, respectively. The accuracy of the method ranged from 95 to 104%. As a proof of concept, the validated method was applied in the determination of flumazenil in plasma from two healthy volunteers participating in a PET study with three repeated investigations. A bolus-infusion protocol was used to achieve a constant concentration level of flumazenil. The average plasma concentrations ranged from 0.11 and 0.19 nM and all measurements were within the calibration standard range. The flumazenil concentrations were relatively constant within each scan and the average intra-scan precision was 15%.

Place, publisher, year, edition, pages
2004. no 808, 221-227 p.
Keyword [en]
Flumazenil
Identifiers
URN: urn:nbn:se:uu:diva-70672OAI: oai:DiVA.org:uu-70672DiVA: diva2:98583
Available from: 2005-04-26 Created: 2005-04-26 Last updated: 2011-01-12

Open Access in DiVA

No full text

Authority records BETA

Lavén, Martin

Search in DiVA

By author/editor
Lavén, Martin
By organisation
Department of Chemistry

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 326 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf