Logotyp: till Uppsala universitets webbplats

uu.sePublikationer från Uppsala universitet
Driftinformation
Ett driftavbrott i samband med versionsuppdatering är planerat till 17/11-2026, kl 12.00-13.00. Under den tidsperioden kommer DiVA inte att vara tillgängligt.
Ändra sökning
Länk till posten
Permanent länk

Direktlänk
Publikationer (10 of 13) Visa alla publikationer
Mattsson, V. (2024). Data-Driven Methods for Microwave Sensor Devices in Musculoskeletal Diagnostics. (Doctoral dissertation). Uppsala: Acta Universitatis Upsaliensis
Öppna denna publikation i ny flik eller fönster >>Data-Driven Methods for Microwave Sensor Devices in Musculoskeletal Diagnostics
2024 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Microwave sensors can be used within medicine as they use non-ionizing radiation, are often low cost, and can be designed for a specific purpose. The application of microwave sensors for diagnostics and monitoring can be improved using appropriate data analysis. The multi-layered structure of the human body makes the measurements on people complex. A tremendous effort is required to create an analytical model of the body. In this context a data-driven approach, building a model that learns from previous measurements, is more suitable to analyze the data. This thesis aims to address statistical and data-driven approaches based on microwave sensor data for biomedical applications.

A significant part of this thesis deals with microwave sensors for assessing muscle quality. It details the progress from initial clinical campaign to the creation of a machine learning algorithm to assess the local body composition. Such a device would be suitable for screening age-related muscle disorders like sarcopenia and muscle atrophy. Statistical analysis following the initial clinical campaign revealed no significant differences in the microwave data. Therefore, new sensor designs were evaluated. The most promising sensor was used in a small clinical campaign where it was able to detect a change in muscle size for one patient with multiple measurements over time. Successive measurements followed on tissue emulating phantoms and volunteers. For data analysis a machine learning algorithm was designed to predict the skin, fat, and muscle properties. This changes the aim from assessing muscle quality to assessing local body composition. For phantom data the algorithm was accurate for skin and fat and for volunteer data for fat and muscle. Crucially, the algorithm also performed better with more data available, meaning that results should improve if more data is collected.

Microwave sensors have also been employed to assess bone. The first of two applications was to monitor the bone healing progression post surgery treating craniosynostosis. No substantial conclusions could be drawn from the statistical analysis most likely due to measurement uncertainties. The second application used a purpose-built setup for controlled measurements in ex vivo bone samples submerged in liquid, to simulate an in vivo environment. The purpose was to estimate the dielectric properties of bone. The derived bone properties were lower than expected, probably due to air trapped inside the sample.

Ort, förlag, år, upplaga, sidor
Uppsala: Acta Universitatis Upsaliensis, 2024. s. 93
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 2359
Nyckelord
Machine Learning, Microwave Sensors, Data-Driven Modeling, Statistical Analysis, Maskininlärning, Mikrovågssensorer, Datadriven modellering, Statistisk Analys
Nationell ämneskategori
Signalbehandling Annan data- och informationsvetenskap Annan medicinteknik
Forskningsämne
Teknisk fysik med inriktning mot elektronik
Identifikatorer
urn:nbn:se:uu:diva-521537 (URN)978-91-513-2021-2 (ISBN)
Disputation
2024-03-15, lecture room Heinz-Otto Kreiss, Lägerhyddsvägen 1, Uppsala, 09:00 (Engelska)
Opponent
Handledare
Tillgänglig från: 2024-02-20 Skapad: 2024-01-25 Senast uppdaterad: 2026-06-01
Mattsson, V., Perez, M. D., Joseph, L. & Augustine, R. (2024). Machine Learning Algorithm to Extract Properties of ATE Phantoms from Microwave Measurements. International journal of microwave and wireless technologies, 16(10), 1624-1631
Öppna denna publikation i ny flik eller fönster >>Machine Learning Algorithm to Extract Properties of ATE Phantoms from Microwave Measurements
2024 (Engelska)Ingår i: International journal of microwave and wireless technologies, ISSN 1759-0795, E-ISSN 1759-0787, Vol. 16, nr 10, s. 1624-1631Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The Muscle Analyzer System (MAS) project wants to create a standalone microwave device that can assess the muscle quality, called the MAS device. To achieve that an algorithm that can derive the properties of skin, fat and muscle from the measurements is needed. This paper presents a machine learning algorithm that aims to do precisely that. The algorithm relies on first predicting the skin using the data from the MAS device, then predicting the fat again using the data from the MAS but also the predicted skin value and lastly the muscle is predicted using the microwave data together with the skin and fat predictions. Data have been collected in phantom experiments, materials that mimick the dielectric properties of human tissues. The algorithm is trained to predict the properties of said phantoms. The results show that the prediction for skin thickness works well, the fat thickness prediction is okay but the muscle prediction struggles. This is partly due to the error from the skin and fat layers are propagated to the muscle layer and partly because the muscle layer is farthest away from the sensor, which makes getting information from that layer harder.

Ort, förlag, år, upplaga, sidor
Cambridge University Press, 2024
Nationell ämneskategori
Signalbehandling Medicinsk instrumentering
Identifikatorer
urn:nbn:se:uu:diva-521534 (URN)10.1017/S1759078724000102 (DOI)001157395400001 ()2-s2.0-85184581625 (Scopus ID)
Tillgänglig från: 2024-01-25 Skapad: 2024-01-25 Senast uppdaterad: 2026-02-26Bibliografiskt granskad
Mattsson, V., Perez, M. D., Ackermans, L. L. G., Meaney, P., Bosch, J. A. T., Blokhuis, T. J. & Augustine, R. (2024). Machine Learning Powered Microwave Device for Local Body Composition Assessment. IEEE Sensors Journal, 24(5), 7030-7041
Öppna denna publikation i ny flik eller fönster >>Machine Learning Powered Microwave Device for Local Body Composition Assessment
Visa övriga...
2024 (Engelska)Ingår i: IEEE Sensors Journal, ISSN 1530-437X, E-ISSN 1558-1748, Vol. 24, nr 5, s. 7030-7041Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In this paper a standalone microwave device is evaluated for its ability to assess local body composition with the ultimate goal to assess muscle quality. Data have been collected from volunteers who were measured on their thigh using the microwave device and ultrasound. A machine learning algorithm with three stages is designed that utilizes the stacked nature of the tissues in the thigh to predict skin and fat thickness and the cross-sectional area of the rectus femoris muscle. The input to the algorithm is the signal response from the microwave sensor and also the prediction from the previous layers. The ultrasound measurements are used as the ground truth labels for each tissue to train the machine learning models. The measurements were performed with two sensors, where usage of the combined data from both sensors produced the best results for fat and muscle, 0.57 and 0.63 in R 2 score, respectively. In the drop analysis, a step where a select proportion of the data is temporarily removed, the identified models showed increased scores with a larger amount of data available indicating the learning of the models improves with more data. Although the results are encouraging more data is ultimately needed to further study the algorithm.

Ort, förlag, år, upplaga, sidor
Institute of Electrical and Electronics Engineers (IEEE), 2024
Nyckelord
Muscles;Sensors;Fats;Phantoms;Ultrasonic variables measurement;Skin;Machine learning;Biomedical signal processing;Machine learning;Microwave sensor;Signal analysis
Nationell ämneskategori
Signalbehandling Medicinsk instrumentering
Identifikatorer
urn:nbn:se:uu:diva-521533 (URN)10.1109/JSEN.2023.3344581 (DOI)001280078400001 ()2-s2.0-85181565370 (Scopus ID)
Tillgänglig från: 2024-01-25 Skapad: 2024-01-25 Senast uppdaterad: 2025-02-20Bibliografiskt granskad
Meaney, P. M., Mattsson, V., Augustine, R. & Brisby, H. (2024). Microwave Vertebrae Strength Probe Development: Robust and Fast Phase Unwrapping Technique. IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology, 8(1), 78-83
Öppna denna publikation i ny flik eller fönster >>Microwave Vertebrae Strength Probe Development: Robust and Fast Phase Unwrapping Technique
2024 (Engelska)Ingår i: IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology, ISSN 2469-7257, Vol. 8, nr 1, s. 78-83Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

We have developed a new transmission-based, open-ended coaxial probe for assessing vertebrae strength during spinal fusion surgery. The approach exploits the fact that the probes are within the far field of each other implying that the phase varies linearly with respect to propagation distance. Determining the absolute phase is critical for recovering the associated tissue dielectric properties from which bone strength will be determined. Unfortunately, unwanted multi-path signals corrupt the signals at the lower end of the operating frequency range from which our conventional unwrapping strategy depends. Our new approach requires only three measurements within the prime frequency range and can be determined robustly with a minimum of computations. This will be vital to developing a commercial device since the signal levels will be extremely low power requiring longer than usual data acquisition times, which will be mitigated by measuring the data at only a few frequencies. Fast and efficient operation will be critical for clinical success.

Ort, förlag, år, upplaga, sidor
Institute of Electrical and Electronics Engineers (IEEE), 2024
Nyckelord
Phase unwrapping, vertebrae, instrumentation, osteoporosis, microwave, transmission probe
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
urn:nbn:se:uu:diva-528600 (URN)10.1109/JERM.2024.3363148 (DOI)001175793600001 ()
Tillgänglig från: 2024-05-24 Skapad: 2024-05-24 Senast uppdaterad: 2024-05-24Bibliografiskt granskad
Meaney, P., Mattsson, V., Augustine, R., Rydholm, T. & Brisby, H. (2023). Vertebrae Transmission Probe Testing - Preliminary Bone Measurements. In: 2023 17th European Conference on Antennas and Propagation, EuCAP: . Paper presented at 17th European Conference on Antennas and Propagation (EuCAP), MAR 26-31, 2023, Florence, ITALY. Institute of Electrical and Electronics Engineers (IEEE)
Öppna denna publikation i ny flik eller fönster >>Vertebrae Transmission Probe Testing - Preliminary Bone Measurements
Visa övriga...
2023 (Engelska)Ingår i: 2023 17th European Conference on Antennas and Propagation, EuCAP, Institute of Electrical and Electronics Engineers (IEEE), 2023Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

We are developing a new transmission-based probe for assessing vertebrae strength via the differences between the dielectric properties of normal and osteoporotic bone. The probes are simple open-ended coaxial cables that will fit easily into the pedicle canals drilled by the surgeons before implanting screws to secure the supporting instrumentation. If the screws pull because of bone weakness, it can inflict a wide range of complications. In the progression towards actual clinical trials, we have already validated the approach on different liquids with varying dielectric properties. In this study, we assess actual animal bone samples as a precursor to human investigations. We exploit the fact that the trabecular bone is considerably different on opposite sides of the growth plate of long bones such as the femur - somewhat mimicking differences between normal and osteoporotic bone. For these experiments, we show that the properties of the distal and proximal sections are considerably different and present opportunities to exploit them in a diagnostic setting

Ort, förlag, år, upplaga, sidor
Institute of Electrical and Electronics Engineers (IEEE), 2023
Serie
Proceedings of the European Conference on Antennas and Propagation, ISSN 2164-3342
Nyckelord
vertebrae, transmission probe, far-field, dielectric properties
Nationell ämneskategori
Ortopedi Annan elektroteknik och elektronik
Identifikatorer
urn:nbn:se:uu:diva-511597 (URN)10.23919/EuCAP57121.2023.10133241 (DOI)001023316901104 ()2-s2.0-85162214577 (Scopus ID)978-88-31299-07-7 (ISBN)978-1-6654-7541-9 (ISBN)
Konferens
17th European Conference on Antennas and Propagation (EuCAP), MAR 26-31, 2023, Florence, ITALY
Tillgänglig från: 2023-09-18 Skapad: 2023-09-18 Senast uppdaterad: 2025-11-19Bibliografiskt granskad
Mattsson, V. (2022). Evaluation of biomedical microwave sensors: Microwave sensors as muscle quality discriminators in laboratory and pilot clinical trial settings. (Licentiate dissertation).
Öppna denna publikation i ny flik eller fönster >>Evaluation of biomedical microwave sensors: Microwave sensors as muscle quality discriminators in laboratory and pilot clinical trial settings
2022 (Engelska)Licentiatavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

In this thesis the primary focus is on the evaluation of biomedical microwave sensor to be used in the muscle analyzer system. Lower muscle quality is one indicator that a patient can have sarcopenia. Therefore the muscle analyzer system can be a tool used in screening for sarcopenia. Sarcopenia is a progressive skeletal muscle disorder that typically affects elderly people. It is characterized by several different things, one of them is that there is an infiltration of fat into the muscle. At microwave frequencies the dielectric properties of fat are vastly different than the muscles. So, this fat infiltration creates a dielectric contrast compared to muscle without this fat infiltration that the sensors aim to detect.

The muscle analyzer system is proposed to be a portable device that can be employed in clinics to assess muscle quality. The sensors are evaluated on their ability to distinguish between normal muscle tissue and muscle of lower quality. This is achieved via electromagnetic simulations, clinical trials, where the system is compared against established techniques, and phantom experiments, where artificial tissue emulating materials is used in a laboratory setting to mimick the properties of human tissues.

In a initial clinical pilot study the split ring resonator sensor was used, but the results raised concerns over the penetration depth of the sensor. Therefore, three new alternative sensors were designed and evaluated via simulations. Two of the new sensors showed encouraging results, one of which has been fabricated. This sensor was used in a another clinical study.This study only had data from 4 patients, 8 measurements in total, meaning it was hard to draw any conclusions from it. The sensors used in the clinical setting as well as another were evaluated in the phantom experiments. Those experiments were exploratory because a wider frequency range was used, although some problems in the experiments were found.

A secondary approach in this thesis is devoted to a data-driven approach, where a microwave sensor is simulated. The data from it is simulated and used to train a neural network to predict the dielectric properties of materials. The network predicts these properties with relatively high accuracy. However, this approach is currently limited to simulations only. Several ideas on how to improve this approach and extend it to measurements is given.

Förlag
s. 75
Nyckelord
Microwave sensors, Sarcopenia, Muscle quality assessment, Biomedical applications, Tissue dielectric properties, Data-driven modelling, Clinical trials, EM Simulations, Phantom experiments
Nationell ämneskategori
Medicinsk instrumentering Annan elektroteknik och elektronik
Forskningsämne
Teknisk fysik med inriktning mot elektronik
Identifikatorer
urn:nbn:se:uu:diva-466137 (URN)
Presentation
2022-03-31, Heinz-Otto Kreiss, 101195, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 09:15 (Engelska)
Opponent
Handledare
Tillgänglig från: 2022-03-09 Skapad: 2022-02-09 Senast uppdaterad: 2025-02-10
Mattsson, V., Pérez, M. D., Ackermans, L. L. G., Vesseur, M. A. .., Bels, J. L. M., van de Poll, M. C. G., . . . Augustine, R. (2022). Muscle Analyzer System: Exploring Correlation Between Novel Microwave Resonator and Ultrasound-based Tissue Information in the Thigh. In: 2022 16th European Conference on Antennas and Propagation (EuCAP): . Paper presented at 16th European Conference on Antennas and Propagation (EuCAP) 2022, 27 March-1 April, Madrid, Spain. Institute of Electrical and Electronics Engineers (IEEE), Article ID 9769216.
Öppna denna publikation i ny flik eller fönster >>Muscle Analyzer System: Exploring Correlation Between Novel Microwave Resonator and Ultrasound-based Tissue Information in the Thigh
Visa övriga...
2022 (Engelska)Ingår i: 2022 16th European Conference on Antennas and Propagation (EuCAP), Institute of Electrical and Electronics Engineers (IEEE), 2022, artikel-id 9769216Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

A microwave sensor to safely measure quality of muscle tissue for diagnosis and screening of diseases and medical conditions characterized by fat infiltration in muscle is presented. Fat infiltration in muscle may be seen by a lower dielectric constant of muscle at microwave frequencies corresponding to the large contrast between fat and muscle tissues. A planar resonator based on a bandstop filter and optimized to noninvasively interrogate muscle in the thigh on tissue quality is proposed. Currently, a study based on clinical trials is carried out, and, here, we present a preliminary correlation between skin and fat thicknesses and rectus femoris cross sectional area (CSA) measured with ultrasound and the proposed sensor's resonance frequency. CST simulations based on the ultrasound information guide the analysis. We see that although there are signs of a potential correlation between CSA and resonance, skin and fat variability is still an issue to overcome.

Ort, förlag, år, upplaga, sidor
Institute of Electrical and Electronics Engineers (IEEE), 2022
Nyckelord
Sensors, Muscle Quality, Bandstop Filter, Clinical Measurements
Nationell ämneskategori
Annan elektroteknik och elektronik Medicinsk instrumentering
Identifikatorer
urn:nbn:se:uu:diva-466134 (URN)10.23919/EuCAP53622.2022.9769216 (DOI)000815113901017 ()978-88-31299-04-6 (ISBN)978-1-6654-1604-7 (ISBN)
Konferens
16th European Conference on Antennas and Propagation (EuCAP) 2022, 27 March-1 April, Madrid, Spain
Tillgänglig från: 2022-01-24 Skapad: 2022-01-24 Senast uppdaterad: 2026-09-18Bibliografiskt granskad
Mattsson, V., Ackermans, L. L. G., Mandal, B., Perez, M. D., Vesseur, M. A. M., Meaney, P., . . . Augustine, R. (2021). MAS: Standalone Microwave Resonator to Assess Muscle Quality. Sensors, 21(16), Article ID 5485.
Öppna denna publikation i ny flik eller fönster >>MAS: Standalone Microwave Resonator to Assess Muscle Quality
Visa övriga...
2021 (Engelska)Ingår i: Sensors, E-ISSN 1424-8220, Vol. 21, nr 16, artikel-id 5485Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Microwave-based sensing for tissue analysis is recently gaining interest due to advantages such as non-ionizing radiation and non-invasiveness. We have developed a set of transmission sensors for microwave-based real-time sensing to quantify muscle mass and quality. In connection, we verified the sensors by 3D simulations, tested them in a laboratory on a homogeneous three-layer tissue model, and collected pilot clinical data in 20 patients and 25 healthy volunteers. This report focuses on initial sensor designs for the Muscle Analyzer System (MAS), their simulation, laboratory trials and clinical trials followed by developing three new sensors and their performance comparison. In the clinical studies, correlation studies were done to compare MAS performance with other clinical standards, specifically the skeletal muscle index, for muscle mass quantification. The results showed limited signal penetration depth for the Split Ring Resonator (SRR) sensor. New sensors were designed incorporating Substrate Integrated Waveguides (SIW) and a bandstop filter to overcome this problem. The sensors were validated through 3D simulations in which they showed increased penetration depth through tissue when compared to the SRR. The second-generation sensors offer higher penetration depth which will improve clinical data collection and validation. The bandstop filter is fabricated and studied in a group of volunteers, showing more reliable data that warrants further continuation of this development.

Ort, förlag, år, upplaga, sidor
MDPIMDPI AG, 2021
Nyckelord
muscle quality, sarcopenia, microwave sensing, bandstop filter, substrate integrated waveguides
Nationell ämneskategori
Medicinsk laboratorieteknik
Identifikatorer
urn:nbn:se:uu:diva-455509 (URN)10.3390/s21165485 (DOI)000690024700001 ()34450927 (PubMedID)
Tillgänglig från: 2021-10-07 Skapad: 2021-10-07 Senast uppdaterad: 2025-02-09Bibliografiskt granskad
Mattsson, V., Perez, M. D., Dematties, D. & Augustine, R. (2020). Neural Network Approach for Dielectric Characterization of Tissues in Microwave Frequencies using Coplanar Waveguide Transmission. In: 2020 14th European Conference on Antennas and Propagation (EuCAP): . Paper presented at 14th European Conference on Antennas and Propagation (EuCAP), MAR 15-20, 2020, Copenhagen, DENMARK.
Öppna denna publikation i ny flik eller fönster >>Neural Network Approach for Dielectric Characterization of Tissues in Microwave Frequencies using Coplanar Waveguide Transmission
2020 (Engelska)Ingår i: 2020 14th European Conference on Antennas and Propagation (EuCAP), 2020Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

This paper presents an extension to previous work, using neural networks to characterize materials in microwave frequencies, to extend the applicability of a deep learning model to be able to characterize the dielectric properties of biological tissues. A neural network model using convolutional and fully connected layers is designed to predict the permittivity and loss tangent using the scattering parameters from a coplanar waveguide transmission sensor. Simulated data from the sensor provide a large dataset, with a wide range of values for the permittivity and loss tangent, which is used to train and test the model. The trained network is validated by predicting the output parameters on the test set. Compared with previous work, by using convolutional layers the applicable parameter space is vastly extended while keeping satisfying levels of accuracy. A complete system with a trained network is proposed to be used in a lab or in clinics.

Serie
Proceedings of the European Conference on Antennas and Propagation, ISSN 2164-3342
Nyckelord
microwave sensor, convolutional neural network, simulation, dielectric properties
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
urn:nbn:se:uu:diva-424367 (URN)10.23919/EuCAP48036.2020.9135949 (DOI)000564218703094 ()978-88-31299-00-8 (ISBN)
Konferens
14th European Conference on Antennas and Propagation (EuCAP), MAR 15-20, 2020, Copenhagen, DENMARK
Forskningsfinansiär
Vinnova, 2015-04159Vetenskapsrådet, 2017-04644EU, Horisont 2020, 824984Stiftelsen för strategisk forskning (SSF), RIT170020
Tillgänglig från: 2020-11-05 Skapad: 2020-11-05 Senast uppdaterad: 2022-02-09Bibliografiskt granskad
Redzwan, S., Asan, N. B., Velander, J., Ebrahimizadeh, J., Perez, M. D., Mattsson, V., . . . Augustine, R. (2019). Analysis of Thickness Variation in Biological Tissues using Microwave Sensors for Health Monitoring Applications. IEEE Access, 7, 156033-156043
Öppna denna publikation i ny flik eller fönster >>Analysis of Thickness Variation in Biological Tissues using Microwave Sensors for Health Monitoring Applications
Visa övriga...
2019 (Engelska)Ingår i: IEEE Access, E-ISSN 2169-3536, Vol. 7, s. 156033-156043Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Microwave sensing technique is a possible and attractive alternative modality to standard Xrays,magnetic resonance imaging, and computed tomography methods for medical diagnostic applications.This technique is beneficial since it uses non-ionizing radiation and that can be potentially used for themicrowave healthcare system. The main purpose of this paper is to present a microwave sensing techniqueto analyze the variations in biological tissue thickness, considering the effect of physiological and biologicalproperties on microwave signals. With this goal, we have developed a two-port non-invasive sensor systemcomposed of two split ring resonators (SRRs) operating at an Industrial, Scientific, and Medical frequencyband of 2.45 GHz. The system is verified using the amplitude and phase of the transmitted signal in ex-vivomodels, representing different tissue thicknesses. Clinical applications such as the diagnosis of muscularatrophy can be benefitted from this study.

Nationell ämneskategori
Annan elektroteknik och elektronik
Forskningsämne
Teknisk fysik med inriktning mot mikrovågsteknik
Identifikatorer
urn:nbn:se:uu:diva-392816 (URN)10.1109/ACCESS.2019.2949179 (DOI)000497165400059 ()
Forskningsfinansiär
Vinnova, 2015-04159Vetenskapsrådet, 2017-04644EU, Horisont 2020, 824984Stiftelsen för strategisk forskning (SSF), RIT170020
Tillgänglig från: 2019-09-10 Skapad: 2019-09-10 Senast uppdaterad: 2019-12-06Bibliografiskt granskad
Organisationer
Identifikatorer
ORCID-id: ORCID iD iconorcid.org/0000-0001-8065-0094

Sök vidare i DiVA

Visa alla publikationer