Logo: to the web site of Uppsala University

uu.sePublications from Uppsala University
System disruptions
There are recurring service disruptions on some of the search portals due to high traffic. We are working to resolve the issue, you may temporarily encounter an error message.
Change search
Link to record
Permanent link

Direct link
Publications (4 of 4) Show all publications
Hogmark, S., Rydelius, J., Envall, N., Teleman, P., Gemzell-Danielsson, K. & Kallner, H. K. (2024). Placement of an intrauterine device within 48 hours after second-trimester medical abortion: a randomized controlled trial. American Journal of Obstetrics and Gynecology, 231(5), 530e1-530e8
Open this publication in new window or tab >>Placement of an intrauterine device within 48 hours after second-trimester medical abortion: a randomized controlled trial
Show others...
2024 (English)In: American Journal of Obstetrics and Gynecology, ISSN 0002-9378, E-ISSN 1097-6868, Vol. 231, no 5, p. 530e1-530e8Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: International guidelines recommend placement of intrauterine devices immediately after second-trimester medical abortion, but evidence concerning the optimal time for intrauterine device placement is lacking from clinical trials. OBJECTIVE: This study aimed to investigate effectiveness, safety, and acceptability of intrauterine device placement within 48 hours, compared with placement at 2 to 4 weeks after second-trimester medical abortion. We hypothesized that intrauterine device placement within 48 hours would be superior compared with placement at 2 to 4 weeks after the abortion, in terms of the proportion of intrauterine device use after 6 months, with maintained safety and acceptability. STUDY DESIGN: In this open-label, randomized, controlled, superiority trial, we recruited participants at 8 abortion clinics in Sweden. Eligible participants were aged >= 18 years, requesting medical abortion with gestation >= 85 days, and opting for use of a postabortion intrauterine device. Participants were randomized (1:1) to intrauterine device placement either within 48 hours of complete abortion (intervention) or after 2 to 4 weeks (control). Our primary outcome was self-reported use of an intrauterine device after 6 months. Secondary outcomes included expulsion rates, pain at placement, adverse events and complications, acceptability, and subsequent pregnancies and abortions. Differences in nonnormal continuous variables were analyzed with the Mann-Whitney U test, and differences in dichotomous variables with the chi-square or Fisher exact tests. A P value <.05 was considered statistically significant. Group differences are presented by modified intention-to-treat and per-protocol analyses. RESULTS: Between January 2019 and June 2022, we enrolled 179 participants, of whom 90 were assigned to the intervention and 89 to the control arm. Enrollment was prematurely stopped after an interim analysis exceeded a predefined intrauterine device expulsion rate of 20%. According to modified intention-to-treat analysis, use of intrauterine device after 6 months was 50.7% (34/67) in the intervention group vs 71.6% (48/ 67) in the control group (proportion difference, 20.9%; 95% confidence interval, 4.4%-35.9%; P=.02). The intrauterine device expulsion rate was 30.1% (22/73) in the intervention group vs 2.9% (2/70; P<.001) in the control group. Other adverse events were rare and patient acceptability was high in both groups. CONCLUSION: Intrauterine device placement within 48 hours after second-trimester medical abortion was nonsuperior in terms of the proportion of intrauterine device use after 6 months when compared with placement after 2 to 4 weeks. Placement within 48 hours after second- trimester abortion can be used in selected individuals after counseling on expulsion risk.

Place, publisher, year, edition, pages
Elsevier, 2024
Keywords
health services accessibility, induced abortion, intrauterine device expulsion, long-acting reversible contraception, medicated intra-uterine devices, postabortion contraception, repeated abortion seekers, contraception, copper intrauterine devices, family planning services
National Category
Gynaecology, Obstetrics and Reproductive Medicine
Identifiers
urn:nbn:se:uu:diva-543285 (URN)10.1016/j.ajog.2024.05.041 (DOI)001347132200001 ()38796039 (PubMedID)2-s2.0-85195668981 (Scopus ID)
Available from: 2024-12-06 Created: 2024-12-06 Last updated: 2025-02-11Bibliographically approved
Hogmark, S., Envall, N., Gemzell-Danielsson, K. & Kallner, H. K. (2023). One-year follow up of contraceptive use and pregnancy rates after early medical abortion: Secondary outcomes from a randomized controlled trial of immediate post-abortion placement of intrauterine devices. Acta Obstetricia et Gynecologica Scandinavica, 102(12), 1694-1702
Open this publication in new window or tab >>One-year follow up of contraceptive use and pregnancy rates after early medical abortion: Secondary outcomes from a randomized controlled trial of immediate post-abortion placement of intrauterine devices
2023 (English)In: Acta Obstetricia et Gynecologica Scandinavica, ISSN 0001-6349, E-ISSN 1600-0412, Vol. 102, no 12, p. 1694-1702Article in journal (Refereed) Published
Abstract [en]

Introduction: Intrauterine devices (IUDs) effectively prevent unwanted pregnancies. Little is known about long-term outcomes of women choosing an IUD after early medical abortion.

Material and methods: We present secondary outcome data of continuation rates, factors associated with continuation and discontinuation, choice of IUD type, women's satisfaction with IUD, and IUD expulsions, subsequent pregnancies, and abortions within 1 year post-abortion in a randomized, controlled, multicenter trial on IUD placement within 48 hours compared with placement 2-4 weeks after medical abortion up to 63 days' gestation ( NCT03603145).

Results: Of the 240 women studied, 112/120 (93.3%) in the intervention group vs 113/120 (94.2%) in the control group completed the 12-month follow-up. The rate of IUD use at 12 months was 84/112 (75%) in the intervention group vs 75/113 (66.4%) in the control group (P = 0.19). Attendance at the IUD placement visit was the only predictor of long-term IUD use (relative risk [RR] = 5.7, 95% confidence interval [CI] 2.03-16.0; P = 0.001). The main reason for choosing an IUD was high contraceptive effectiveness. The most common reasons for IUD discontinuation were bleeding problems and abdominal pain. IUD expulsion was rare and did not differ between groups. Satisfaction among IUD users at 1 year was high (>94%) and the majority of all participants would recommend IUD to a friend (65.8%). Use of no contraception and experience of unprotected intercourse were less common in the intervention group (11/112 [9.8%] vs 25/113 [22.1%], P = 0.02 and 17/112 [15.2%] vs 32/113 [28.3%], P = 0.02, respectively). There was no difference in the rate of subsequent pregnancies and abortions (pregnancies 14/112, 12.5% in the intervention group vs 8/113, 7.1% in the control group, P = 0.19; abortions 5/112, 4.5% vs 3/113, 2.7%, P = 0.5).

Conclusions: IUD placement after medical abortion led to high continuation and satisfaction rates with no difference between groups. We found no difference in IUD expulsions after immediate compared with later placement. Unprotected intercourse was significantly less common in the immediate group. In clinical practice, immediate placement of IUDs available free of charge at the abortion clinic is likely to increase attendance to the placement visit and continued use of IUDs after abortion.

Place, publisher, year, edition, pages
Wiley-Blackwell, 2023
Keywords
abortion, contraception, contraceptive devices, copper intrauterine devices, family planning services, intrauterine devices, long-acting reversible contraceptives, medicated intrauterine devices
National Category
Gynaecology, Obstetrics and Reproductive Medicine Public Health, Global Health and Social Medicine
Identifiers
urn:nbn:se:uu:diva-511152 (URN)10.1111/aogs.14662 (DOI)001053534300001 ()37614066 (PubMedID)2-s2.0-85168627912 (Scopus ID)
Funder
Karolinska Institute, LS-2016-1376Karolinska Institute, RS 2019-1054Karolinska Institute, K 0138-2015Karolinska Institute, LS 2018-1257Swedish Society of Medicine, SLS-692651
Available from: 2023-09-12 Created: 2023-09-12 Last updated: 2026-04-01Bibliographically approved
Hogmark, S., Liljeblad, K. L., Envall, N., Gemzell-Danielsson, K. & Kallner, H. K. (2023). Placement of an intrauterine device within 48 hours after early medical abortion-a randomized controlled trial. American Journal of Obstetrics and Gynecology, 228(1), Article ID 53.
Open this publication in new window or tab >>Placement of an intrauterine device within 48 hours after early medical abortion-a randomized controlled trial
Show others...
2023 (English)In: American Journal of Obstetrics and Gynecology, ISSN 0002-9378, E-ISSN 1097-6868, Vol. 228, no 1, article id 53Article in journal (Refereed) Published
Abstract [en]

BACKGROUND: Intrauterine devices are safe, well-tolerated, and known to reduce the risk of unwanted pregnancies. At medical abortion, intrauterine devices are placed at a follow-up visit. Patients who miss this visit risk being left without contraception.

OBJECTIVE: This study aimed to investigate if placement of an intra-uterine device within 48 hours of completed medical abortion at up to 63 days' gestation leads to higher user rates at 6 months after the abortion compared with placement at 2 to 4 weeks after abortion. Furthermore, we aimed to compare continued use of intrauterine devices, safety, and pa-tient satisfaction between groups.

STUDY DESIGN: We performed an open-label, randomized, controlled, multicenter, superiority trial (phase 3). A total of 240 patients requesting medical abortion at up to 63 days' gestation and opting for an intrauterine device were allocated to placement within 48 hours of complete medical abortion (intervention group) or at 2 to 4 weeks after abortion (control group). We defined the abortion as complete after bleeding with clots and cessation of heavy bleeding following the use of misoprostol. Patients answered questionnaires at 3, 6, and 12 months. The primary outcome was use of intrauterine device at 6 months postabortion. Secondary outcomes included expulsion rate, pain at placement, adverse events and complications from the abortion, acceptability, and pregnancies and their outcomes. Differences in nonparametric continuous variables were analyzed with the Mann-Whitney U test and differences in dichotomous variables with the chi square or Fisher exact tests. A P value of <.05 was considered statistically significant.

RESULTS: In the intervention group, 91 of 111 (82%) participants used an intrauterine device at 6 months after the abortion vs 87 of 112 (77.7%) in the control group, with a difference in proportion of 4.3% (95% confi-dence interval,-0.062 to 0.148; P=.51). Attendance rate and rate of successful intrauterine device placement were similar between the groups. Patients in the intervention group had lower pain scores at placement of the intrauterine device (mean pain score [visual analogue scale], 32.3; standard deviation, 29) compared with the control group (mean pain score [visual analogue scale], 43.4; standard deviation, 27.9; P=.002). Patients preferred their allocated time of placement significantly more often in the intervention group (83/111, 74.8%) than in the control group (70/114, 61.4%; P=.03). Use of ultrasound at intrauterine device placement (because of doubts concerning complete abortion) was more common in the intervention group (43/108, 39.8%) than in the control group (15/101, 14.9%; P <.001), and in one patient in the control group a retained gestational sac was found. Three patients in the intervention group and 2 in the control group had a vacuum aspiration. No difference was found in intrauterine device expulsion rates between the groups. Expulsion during the first 6 months after abortion was experienced by 9 of 97 (9.3%) patients in the intervention group and 4 of 89 (4.5%; P=.25) in the control group. There were no perforations or infections requiring antibiotic treatment.

CONCLUSION: Placement of an intrauterine device within 48 hours after medical abortion at < 63 days' gestation does not lead to higher user rates at 6 months after the abortion compared with intrauterine device placement at 2 to 4 weeks after abortion. When compared with placement at a follow-up visit after 2 to 4 weeks, intrauterine device placement within 48 hours after early medical abortion seems safe, is preferred by patients, and is associated with lower pain scores.

Place, publisher, year, edition, pages
Elsevier, 2023
Keywords
contraception, copper intrauterine devices, family planning services, hormone-releasing intrauterine device, induced abortion, long-acting reversible contraception, medicated intrauterine devices, post-abortion intrauterine device insertion
National Category
Gynaecology, Obstetrics and Reproductive Medicine
Identifiers
urn:nbn:se:uu:diva-496260 (URN)10.1016/j.ajog.2022.07.063 (DOI)000911968200001 ()35970199 (PubMedID)
Funder
Swedish Society of MedicineRegion Stockholm, LS-2016-1376Region Stockholm, RS 2019-1054Region Stockholm, K 0138-2015Region Stockholm, LS 2018-1257
Available from: 2023-02-10 Created: 2023-02-10 Last updated: 2025-02-11Bibliographically approved
Hogmark, S., Envall, N., Wikman, A., Skoglund, C., Kopp Kallner, H. & Hesselman, S. (2022). Provision of long-acting reversible contraception at surgical abortion: A cross-sectional nationwide register study. Acta Obstetricia et Gynecologica Scandinavica, 101(1), 77-83
Open this publication in new window or tab >>Provision of long-acting reversible contraception at surgical abortion: A cross-sectional nationwide register study
Show others...
2022 (English)In: Acta Obstetricia et Gynecologica Scandinavica, ISSN 0001-6349, E-ISSN 1600-0412, Vol. 101, no 1, p. 77-83Article in journal (Refereed) Published
Abstract [en]

Introduction Provision of long-acting reversible contraception (LARC) at surgical abortion is safe, practical, and leads to higher user rates than does delayed provision. The aim of this study was to explore whether provision of LARC at surgical abortion is associated with known risk factors for subsequent abortions and inconsistent use of contraception, including sociodemographic factors and psychiatric disorders.

Material and Methods This was a register-based cross-sectional study of 6251 women having a surgical abortion in Sweden. Data were collected from National health and population registers. Women with procedure codes for surgical abortion were identified in the National Patient Register from October 2016 to December 2018. Information from Statistics Sweden, the National Patient Register, and the Swedish prescribed drug register on sociodemographic factors, psychiatric disorders, and dispensed LARC was added and linked on an individual level. Associations of sociodemographic factors and psychiatric disorders with LARC provision were explored with generalized logit mixed models and presented as crude and adjusted odds ratios with 95% confidence intervals (CIs).

Results The overall rate of LARC provision at the time of the abortion was 2515/6251 (40.2%). Younger age and lower level of education were associated with an increased likelihood of LARC provision. In the study population, 2624/6251 (42.0%) patients had a pre- or post-abortion psychiatric disorder, a factor associated with an increased likelihood of LARC provision compared with women with no such disorders (adjusted odds ratio 1.21; 95% CI 1.08–1.34). The highest rates and odds were seen among women with personality, substance use, and/or neurodevelopmental disorders and among women with multiple psychiatric disorders.

Conclusions Sociodemographic risk factors and psychiatric disorders were associated with increased LARC provision at surgical abortion, indicating that women at high risk of unwanted pregnancies are provided with effective contraception. Still, less than half of all women undergoing surgical abortion were provided with LARC, suggesting that contraceptive access and counseling prior to a surgical abortion can be improved.

Place, publisher, year, edition, pages
John Wiley & Sons, 2022
Keywords
Abortion, attention deficit disorder with hyperactivity, contraception, cross-sectional studies, induced, long-acting reversible contraception, mental disorders, socioeconomic factors
National Category
Gynaecology, Obstetrics and Reproductive Medicine
Identifiers
urn:nbn:se:uu:diva-463748 (URN)10.1111/aogs.14289 (DOI)000716787100001 ()34761384 (PubMedID)
Funder
Swedish Society of Medicine, SLS-692651The Karolinska Institutet's Research Foundation, RS 2019-1054Uppsala University, CKFUU-936900Uppsala University, CKFUU-940743Region Stockholm, RS 2019-1054
Available from: 2022-01-11 Created: 2022-01-11 Last updated: 2025-02-11Bibliographically approved
Organisations
Identifiers
ORCID iD: ORCID iD iconorcid.org/0000-0001-6061-3982

Search in DiVA

Show all publications