Zaborskyte, G., Hjort, K., Lytsy, B. & Sandegren, L. (2025). Parallel within-host evolution alters virulence factors in an opportunistic Klebsiella pneumoniae during a hospital outbreak. Nature Communications, 16(1), Article ID 8727.
Open this publication in new window or tab >>Parallel within-host evolution alters virulence factors in an opportunistic Klebsiella pneumoniae during a hospital outbreak
2025 (English)In: Nature Communications, E-ISSN 2041-1723, Vol. 16, no 1, article id 8727Article in journal (Refereed) Published
Abstract [en]

Bacterial pathogens adapt to host niches because of selective within-host pressures, an evolutionary process that offers invaluable insights into host-pathogen interactions. Here, we retrospectively track the evolution of a single multiresistant Klebsiella pneumoniae clone in 110 patients over a 5-year nosocomial outbreak. We combine comparative genomics with phenotypic characterization of mucoviscosity, serum survival, iron utilization, biofilm formation, and infection potential in Galleria mellonella for all isolates. Strong positive selection within patients targeted key virulence factors. Notably, convergent evolutionary trajectories were dominated by reduced acute virulence and recurrent changes in iron uptake regulation, capsule and lipopolysaccharide, and enhanced biofilm formation. These phenotypic changes likely represent clinical niche adaptations, with some resulting in trade-offs during gastrointestinal colonization. This study underscores the dynamic nature of within-host evolution and its role in shaping virulence in opportunistic pathogens, even on short time scales.

Place, publisher, year, edition, pages
Springer Nature, 2025
National Category
Microbiology in the Medical Area Microbiology
Identifiers
urn:nbn:se:uu:diva-569847 (URN)10.1038/s41467-025-64521-9 (DOI)001585312800004 ()41027917 (PubMedID)2-s2.0-105017646925 (Scopus ID)
Available from: 2025-10-22 Created: 2025-10-22 Last updated: 2025-10-22Bibliographically approved
Blomgren, P.-O., Leo Swenne, C., Lytsy, B. & Hjelm, K. (2024). Hand hygiene knowledge among nurses and nursing students: a descriptive cross-sectional comparative survey using the WHO's "Hand Hygiene Knowledge Questionnaire". Infection Prevention in Practice, 6(2), Article ID 100358.
Open this publication in new window or tab >>Hand hygiene knowledge among nurses and nursing students: a descriptive cross-sectional comparative survey using the WHO's "Hand Hygiene Knowledge Questionnaire"
2024 (English)In: Infection Prevention in Practice, E-ISSN 2590-0889, Vol. 6, no 2, article id 100358Article in journal (Refereed) Published
Abstract [en]

Aim

To determine the level of knowledge and explore the difference of hand hygiene between nursing students and nurses.

Background

Annually, 3.8 million people in Europe acquire healthcare-associated infections, highlighting the importance of hand hygiene. Despite WHO's emphasis on the fact that greater hand hygiene knowledge correlates with improved hand hygiene compliance, several studies have shown knowledge gaps among nurses and nursing students regarding hand hygiene.

Design

Descriptive cross-sectional comparative survey.

Methods

A version of the WHO “Hand Hygiene Knowledge Questionnaire”, translated into Swedish, was used for data collection among nursing students in the first and last semester, and registered nurses from a university and associated hospital. Data were analyzed by descriptive statistics, and comparison between groups with Fisher's exact test, one-way ANOVA, and post-hoc tests (Pairwise Z-Tests, Tukey HSD).

Results

The survey, conducted between December 2020 and January 2021, received responses from 201 participants, including 71 first semester students, 46 last semester students and 84 registered nurses, showing moderate (55.7% [50–74% correct answers]) to good (43.8% [75–100% correct answers]) knowledge levels. First-semester students scored lower (17.0 ± 2.1) than last-semester students (18.8 ± 1.8) and registered nurses (18.3 ± 2.1) out of 25 questions.

Discussion

It is necessary for all groups to receive proper education on hand hygiene knowledge and to have an educational program that does not separate the groups but combines them with continuing education, since the students will someday be influencing future hand hygiene knowledge as a peer, together with the nurse.

Place, publisher, year, edition, pages
Elsevier, 2024
Keywords
Hand hygiene, Healthcare associated infections, Knowledge, Nurses, Nursing student, Questionnaire
National Category
Nursing Infectious Medicine
Identifiers
urn:nbn:se:uu:diva-486918 (URN)10.1016/j.infpip.2024.100358 (DOI)001219572100001 ()38586127 (PubMedID)
Available from: 2022-10-19 Created: 2022-10-19 Last updated: 2026-08-20Bibliographically approved
Lytsy, B., Ljungqvist, B., Nordenadler, J. & Reinmüller, B. (2022). Evaluating the effect of Novarerus NV800 air purifier units during orthopaedic surgery to reduce bioburden in the air. Journal of Hospital Infection, 130, 108-111
Open this publication in new window or tab >>Evaluating the effect of Novarerus NV800 air purifier units during orthopaedic surgery to reduce bioburden in the air
2022 (English)In: Journal of Hospital Infection, ISSN 0195-6701, E-ISSN 1532-2939, Vol. 130, p. 108-111Article in journal (Refereed) Published
Abstract [en]

Background: A locally installed air purifier unit (Novaerus Protect 800) has been shown to reduce the air bioburden in an intensive care unit and the incidence of healthcare -associated infections.

Aim: To explore whether this type of air purifying unit could reduce bacterial concen-trations in the air of an operating room (OR) during orthopaedic surgery, thereby reducing the risk of surgical site infections.

Methods: In this prospective experimental study, undertaken in 2018, three air purifying units were installed in an OR in a Swedish hospital in 2018. The air was actively sampled during 11 operations by a slit-to-slit agar impactor with the air purifying units either switched on or switched off. Air movements were visualized with the aid of smoke in mock-up studies.

Findings: No significant difference in bacterial concentrations in air was found between the two conditions (air purifying units switched off or on) (P1/40.54). Air movements around and above the surgical wound were disordered and resembled those of dilution mixing air.

Conclusion: The three air purifying units installed in the OR did not reduce the airborne bacterial levels in the critical zone during orthopaedic surgery.

Place, publisher, year, edition, pages
Elsevier, 2022
Keywords
Operating theatre, Operating air bioburden, Surgical site infection, Air purifier
National Category
Infectious Medicine
Identifiers
urn:nbn:se:uu:diva-489597 (URN)10.1016/j.jhin.2022.09.005 (DOI)000878555900004 ()36113635 (PubMedID)
Available from: 2022-12-02 Created: 2022-12-02 Last updated: 2023-01-11Bibliographically approved
Lindblad, M., Sütterlin, S., Tano, E., Huss, F. & Lytsy, B. (2022). Infection control measures to stop the spread of sequence type 15 OXA-23-producing Acinetobacter baumannii in a Swedish Burn Center. Burns, 48(8), 1940-1949
Open this publication in new window or tab >>Infection control measures to stop the spread of sequence type 15 OXA-23-producing Acinetobacter baumannii in a Swedish Burn Center
Show others...
2022 (English)In: Burns, ISSN 0305-4179, E-ISSN 1879-1409, Vol. 48, no 8, p. 1940-1949Article in journal (Refereed) Published
Abstract [en]

OBJECTIVE: To describe the course of the outbreak and infection control measures to stop the spread of sequence type 15 OXA-23-producing Acinetobacter baumannii in the Burn Center of Uppsala University Hospital, between November 2014 and the end of April 2015.

METHODS: Compliance with hand hygiene, dress code, and cleaning routines were reviewed, the ward's environment was systematically investigated to identify potential environmental sources. Sampling routines for A. baumannii, from patients and environment, were established, and the epidemiological relationship was analysed for all carbapenem-resistant A. baumannii isolates using arbitrarily primed polymerase chain reaction (AP-PCR) and pulsed-field gel electrophoresis (PFGE).

RESULTS: A total of 54 patients were treated at the burn intensive care unit during the studied, approximately five months period, and an OXA-23-producing A. baumannii was isolated from nine patients (9/54, 17%), whereof two died (2/9, 22.2%). All isolates shared identical PFGE-genotype patterns and belonged to sequence type 15; AP-PCR was eligible for prompt epidemiological investigations.

CONCLUSIONS: Higher awareness and increased compliance with hand hygiene and dress code as well as intensified cleaning protocols of the environment and equipment were successfully established and likely to have led to stop the spread of sequence type 15 OXA-23-producing Acinetobacter baumannii.

Place, publisher, year, edition, pages
Elsevier, 2022
Keywords
Acinetobacter baumannii, Burn intensive care unit, Carbapenem resistance, Outbreak
National Category
Dermatology and Venereal Diseases Infectious Medicine
Identifiers
urn:nbn:se:uu:diva-487678 (URN)10.1016/j.burns.2022.01.018 (DOI)000899578900018 ()35148917 (PubMedID)
Funder
Region Uppsala, ALF 1040129
Available from: 2022-10-31 Created: 2022-10-31 Last updated: 2024-02-20Bibliographically approved
Granqvist, K., Ahlstrom, L., Karlsson, J., Lytsy, B. & Andersson, A. E. (2022). Learning to interact with new technology: Health care workers' experiences of using a monitoring system for assessing hand hygiene - a grounded theory study. American Journal of Infection Control, 50(6), 651-656
Open this publication in new window or tab >>Learning to interact with new technology: Health care workers' experiences of using a monitoring system for assessing hand hygiene - a grounded theory study
Show others...
2022 (English)In: American Journal of Infection Control, ISSN 0196-6553, E-ISSN 1527-3296, Vol. 50, no 6, p. 651-656Article in journal (Refereed) Published
Abstract [en]

Background: Recently, innovative technologies for hand hygiene (HH) monitoring have been developed to improve HH adherence in health care. This study explored health care workers' experiences of using an electronic monitoring system to assess HH adherence. Methods: An electronic monitoring system with digital feedback was installed on a surgical ward and interviews with health care workers using the system (n = 17) were conducted. The data were analyzed according to grounded theory by Strauss and Corbin. Results: Health care workers' experiences were expressed in terms of having trust in the monitoring system, requesting system functionality and ease of use and becoming aware of one's own performance. This resulted in the core category of learning to interact with new technology, summarized as the main strategy when using an electronic monitoring system in clinical settings. The system with digital feedback improved the awareness of HH and individual feedback was preferable to group feedback. Conclusions: Being involved in using and managing a technical innovation for assessing HH adherence in health care is a process of formulating a strategy for learning to interact with new technology. The importance of inviting health care workers to participate in the co-design of technical innovations is crucial, as it creates both trust in the innovation per se and trust in the process of learning how to use it. (C) 2021 The Author(s). Published by Elsevier Inc. on behalf of Association for Professionals in Infection Control and Epidemiology, Inc.

Place, publisher, year, edition, pages
ElsevierElsevier BV, 2022
Keywords
Guideline adherence, Monitoring technology, Human-machine interaction, Qualitative research
National Category
Health Care Service and Management, Health Policy and Services and Health Economy
Identifiers
urn:nbn:se:uu:diva-482485 (URN)10.1016/j.ajic.2021.09.023 (DOI)000830242900010 ()34610392 (PubMedID)
Available from: 2022-08-23 Created: 2022-08-23 Last updated: 2024-01-15Bibliographically approved
Lytsy, B., Hambraeus, A., Ljungqvist, B., Ransjö, U. & Reinmuller, B. (2022). Source strength as a measurement to define the ability of clean air suits to reduce airborne contamination in operating rooms. Journal of Hospital Infection, 119, 9-15
Open this publication in new window or tab >>Source strength as a measurement to define the ability of clean air suits to reduce airborne contamination in operating rooms
Show others...
2022 (English)In: Journal of Hospital Infection, ISSN 0195-6701, E-ISSN 1532-2939, Vol. 119, p. 9-15Article in journal (Refereed) Published
Abstract [en]

Background: Surgical site infections after total hip and knee replacement are linked to the quality of the operating room (OR) air. Applying tight occlusive clothing, effective ventilation and correct working methods are key concepts to obtain low bacterial concentrations in the OR air. The dry penetration test referred to in European standard EN 13795-2:2019 is a screening method for materials used in surgical clothing. Source strength, defined as the dispersal of bacteria-carrying particles from persons during activity, is a functional test of clothing systems and has been calculated in a dispersal chamber and in ORs. Results from both tests can be used when comparing surgical clothing systems. Aim: This study relates results of dry penetration tests to source strength values for five surgical clothing systems available on the Swedish market. Methods: Experimental data are reported on the function of these products, expressed as source strength calculated from results in a dispersal chamber and in ORs during orthopaedic operations. Findings: All materials tested with dry penetration <= 50 colony-forming units (cfu) had source strength values <3 cfu/s for one person in the dispersal chamber, whereas the material of one product when laundered >50 times had source strength in the dispersal chamber of up to 8 cfu/s. Conclusion: The dry penetration test could predict the performance of clean air suits of the same design, but more studies are needed to obtain a more valid correlation. Requirements of source strength should be included in standards. (C) 2021 The Authors. Published by Elsevier Ltd on behalf of The Healthcare Infection Society.

Place, publisher, year, edition, pages
ElsevierElsevier BV, 2022
Keywords
Airborne contamination, Clean air suits, Colony-forming units, Dry penetration, Operating rooms, Source strength
National Category
Infectious Medicine Building Technologies
Identifiers
urn:nbn:se:uu:diva-470957 (URN)10.1016/j.jhin.2021.09.018 (DOI)000766092600002 ()34619268 (PubMedID)
Available from: 2022-04-01 Created: 2022-04-01 Last updated: 2024-01-15Bibliographically approved
Blomgren, P.-O., Lytsy, B., Hjelm, K. & Swenne, C. L. (2021). Healthcare workers' perceptions and acceptance of an electronic reminder system for hand hygiene. Journal of Hospital Infection, 108, 197-204
Open this publication in new window or tab >>Healthcare workers' perceptions and acceptance of an electronic reminder system for hand hygiene
2021 (English)In: Journal of Hospital Infection, ISSN 0195-6701, E-ISSN 1532-2939, Vol. 108, p. 197-204Article in journal (Refereed) Published
Abstract [en]

Background:Healthcare-associated infections (HCAIs) have a large negative impact onmorbidity, mortality, and quality of life. Approximately 9% of all patients hospitalized inSweden suffer from HCAI. Hand hygiene plays a key role and is considered the single mostimportant measure to reduce HCAI. The hospital organization works actively to reduceHCAI. Implementing electronic systems to remind and/or notify healthcare workers raisesawareness of and adherence to hand hygiene. However, there is a paucity of studiesaddressing individuals’ perceptions of having such a system and how the organizationworks.

Aim:To investigate healthcare workers’ perceptions of infection prevention in thehealthcare organization and perceptions and acceptance of an electronic reminder systemthat encourages good hand hygiene.

Methods:Qualitative descriptive design with data collected in eight focus group inter-views including assistant nurses, nurses, and physicians (N¼38). Content analysis wasapplied and data were related to the Theory of Planned Behaviour.

Findings:Healthcare workers perceive lack of feedback from the hospital organizationand are positive towards an electronic reminder system to increase adherence to handhygiene. The electronic reminder system should not register data at an individual levelsince it could be used as an instrument for control by the management that could bestressful for staff.

Conclusion:In general, there is positive acceptance of the electronic reminder system,and the respondents perceived it as having the ability to change behaviour. However, theconcept has to be further developed to protect the individual’s integrity and needs to beused with feedback on a group level

Place, publisher, year, edition, pages
Elsevier, 2021
Keywords
Cross-infection, Healthcare-associated infection, Perception, Reminder systems
National Category
Other Basic Medicine Health Care Service and Management, Health Policy and Services and Health Economy
Identifiers
urn:nbn:se:uu:diva-429559 (URN)10.1016/j.jhin.2020.12.005 (DOI)000747809800025 ()33309939 (PubMedID)
Available from: 2021-01-04 Created: 2021-01-04 Last updated: 2026-08-20Bibliographically approved
Aganovic, A., Cao, G., Fecer, T., Ljungqvist, B., Lytsy, B., Radtke, A., . . . Traversari, R. (2021). Ventilation design conditions associated with airborne bacteria levels within the wound area during surgical procedures: a systematic review. Journal of Hospital Infection, 113, 85-95
Open this publication in new window or tab >>Ventilation design conditions associated with airborne bacteria levels within the wound area during surgical procedures: a systematic review
Show others...
2021 (English)In: Journal of Hospital Infection, ISSN 0195-6701, E-ISSN 1532-2939, Vol. 113, p. 85-95Article, review/survey (Refereed) Published
Abstract [en]

Without confirmation of the ventilation design conditions (typology and airflow rate), the common practice of identifying unidirectional airflow (UDAF) systems as equivalent to ultra-clean air ventilation systems may be misleading, but also any claims about the ineffectiveness of UDAF systems should be doubted. The aim of this review was to assess and compare ventilation system design conditions for which ultra-clean air (mean <10 cfu/m3) within 50 cm from the wound has been reported. Six medical databases were systematically searched to identify and select studies reporting intraoperative airborne levels expressed as cfu/m3 close to the wound site, and ventilation system design conditions. Available data on confounding factors such as the number of persons present in the operating room, number of door openings, and clothing material were also included. Predictors for achieving mean airborne bacteria levels within <10 cfu/m3 were identified using a penalized multivariate logistic regression model. Twelve studies met the eligibility criteria and were included for analysis. UDAF systems considered had significantly higher air volume flows compared with turbulent ventilation (TV) systems considered. Ultra-clean environments were reported in all UDAF-ventilated (N = 7) rooms compared with four of 11 operating rooms equipped with TV. On multivariate analysis, the total number of air exchange rates (P=0.019; odds ratio (OR) 95% confidence interval (CI): 0.66–0.96) and type of clothing material (P=0.031; OR 95% CI: 0.01–0.71) were significantly associated with achieving mean levels of airborne bacteria <10 cfu/m3. High-volume UDAF systems complying with DIN 1946-4:2008 standards for the airflow rate and ceiling diffuser size unconditionally achieve ultra-clean air close to the wound site. In conclusion, the studied articles demonstrate that high-volume UDAF systems perform as ultra-clean air systems and are superior to TV systems in reducing airborne bacteria levels close to the wound site.

Place, publisher, year, edition, pages
Elsevier, 2021
Keywords
Ultra-clean air, Intraoperative airborne contamination, Ventilation system, Unidirectional airflow (UDAF), Operating room
National Category
Infectious Medicine
Identifiers
urn:nbn:se:uu:diva-453057 (URN)10.1016/j.jhin.2021.04.022 (DOI)000663832300012 ()33930488 (PubMedID)
Available from: 2021-09-16 Created: 2021-09-16 Last updated: 2024-01-15Bibliographically approved
Pasquarella, C., Agodi, A., Auxilia, F., Lytsy, B., Mura, I., Parneix, P., . . . Brusaferro, S. (2020). Air quality in the operating theatre: a perspective. Aerobiologia, 36(1), 113-117
Open this publication in new window or tab >>Air quality in the operating theatre: a perspective
Show others...
2020 (English)In: Aerobiologia, ISSN 0393-5965, E-ISSN 1573-3025, Vol. 36, no 1, p. 113-117Article in journal (Refereed) Published
Abstract [en]

Operating theatres are among the hospital's most risky environments as far as infections are concerned. Surgical site infection is a serious complication of surgery, associated with increased morbidity, mortality and costs. The ambient air of the operating theatre represents an important vehicle of micro-organisms causing surgical site infection, in particular in clean operations. The aim of this paper is to give a brief historical excursus of the milestones of the prevention of airborne surgical site infections. The debated issue on the use of unidirectional airflow ventilation system is presented. Some national recommendations for threshold air microbial contamination values are reported, and the need for a European standard on air quality to provide a safe operating theatre environment for surgical patients is underlined.

Keywords
Operating theatre, Air quality, Micro-organisms
National Category
Infectious Medicine
Identifiers
urn:nbn:se:uu:diva-410063 (URN)10.1007/s10453-019-09584-0 (DOI)000524225000017 ()
Available from: 2020-05-26 Created: 2020-05-26 Last updated: 2020-05-26Bibliographically approved
Whyte, W. & Lytsy, B. (2020). Criticisms of Teo et al.’s study of ultraclean air systems in operating theatres: Letter to the Editor [Letter to the editor]. Journal of Hospital Infection, 105, 339-340
Open this publication in new window or tab >>Criticisms of Teo et al.’s study of ultraclean air systems in operating theatres: Letter to the Editor
2020 (English)In: Journal of Hospital Infection, ISSN 0195-6701, E-ISSN 1532-2939, Vol. 105, p. 339-340Article in journal, Letter (Other academic) Published
Place, publisher, year, edition, pages
Elsevier, 2020
Keywords
Infection prevention and control, operating theatre, ventilation, air
National Category
Microbiology in the medical area
Identifiers
urn:nbn:se:uu:diva-429560 (URN)10.1016/j.jhin.2020.02.001 (DOI)000539315000040 ()2-s2.0-85082702117 (Scopus ID)
Available from: 2021-01-04 Created: 2021-01-04 Last updated: 2025-03-07Bibliographically approved
Organisations
Identifiers
ORCID iD: ORCID iD iconorcid.org/0000-0002-1322-7744

Search in DiVA

Show all publications