Logo: to the web site of Uppsala University

uu.sePublikasjoner fra Uppsala universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Microfluidics in Surface Modified PDMS: Towards Miniaturized Diagnostic Tools
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för teknikvetenskaper.
2006 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

There is a strong trend in fabricating miniaturized total analytical systems, µTAS, for various biochemical and cell biology applications. These miniaturized systems could e.g. gain better separation performances, be faster, consume less expensive reagents and be used for studies that are difficult to access in the macro world. Disposable µTAS eliminate the risk of carry-over and can be fabricated to a low cost.

This work focused on the development of µTAS modules with the intentional use for miniaturized diagnostics. Modules for blood separation, desalting, enrichment, separation and ESI-MS detection were successfully fabricated. Surface coatings were additionally developed and evaluated for applications in µTAS with complex biological samples. The first heparin coating could be easily immobilized in a one-step-process, whereas the second heparin coating was aimed to form a hydrophilic surface that was able to draw blood or plasma samples into a microfluidic system by capillary forces.

The last mentioned heparin surface was further utilized when developing a chip-based sensor for performing CD4-count in human blood, an important marker to determine the stage of an HIV-infection.

All devices in this work were fabricated in PDMS, an elastomeric polymer with the advantage of rapid and less expensive prototyping of the microfabricated master. It was shown that PDMS could be considered as the material of choice for future commercial µTAS. The devices were intentionally produced using a low grade of fabrication complexity. It was however demonstrated that even with low complexity, it is possible to integrate several functional chip modules into a single microfluidic device.

sted, utgiver, år, opplag, sider
Uppsala: Acta Universitatis Upsaliensis , 2006. , s. 52
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 241
Emneord [en]
Materials science, µTAS, micro total analysis system, PDMS, poly(dimethylsiloxane), microfluidics, heparin, blood filtration, on-chip, ESI-MS, desalting, QCM-D, biocompatible, CD4, capillary flow, lab-on-chip, microfabrication, enrichment, point-of-care, hydrophilic, oxidation
Emneord [sv]
Materialvetenskap
Identifikatorer
URN: urn:nbn:se:uu:diva-7270ISBN: 91-554-6716-4 (tryckt)OAI: oai:DiVA.org:uu-7270DiVA, id: diva2:169223
Disputas
2006-12-08, Polhemsalen, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 09:30
Opponent
Veileder
Tilgjengelig fra: 2006-11-17 Laget: 2006-11-17bibliografisk kontrollert
Delarbeid
1. A hybrid poly(dimethylsiloxane) microsystem for on-chip whole blood filtration optimized for steroid screening
Åpne denne publikasjonen i ny fane eller vindu >>A hybrid poly(dimethylsiloxane) microsystem for on-chip whole blood filtration optimized for steroid screening
Vise andre…
2006 (engelsk)Inngår i: Biomedical Microdevices, ISSN 1387-2176, Vol. 8, nr 1, s. 73-79Artikkel i tidsskrift (Fagfellevurdert) Published
HSV kategori
Identifikatorer
urn:nbn:se:uu:diva-95123 (URN)
Tilgjengelig fra: 2006-11-17 Laget: 2006-11-17 Sist oppdatert: 2016-06-22
2. Functionality and stability of heparin immobilized onto poly(dimethylsiloxane)
Åpne denne publikasjonen i ny fane eller vindu >>Functionality and stability of heparin immobilized onto poly(dimethylsiloxane)
Vise andre…
2005 (engelsk)Inngår i: Colloids and Surfaces B: Biointerfaces, ISSN 0927-7765, E-ISSN 1873-4367, Vol. 45, nr 2, s. 76-81Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Poly(dimethylsiloxane) (PDMS) has become an attractive material when working in the field of microfluidics, mainly because of the rapid prototyping process it involves. The increased surface volume ratio in microchannels makes the interaction between sample and material surface highly important, evident when handling complex biological samples such as plasma or blood. This study demonstrates a new grade of non-covalent heparin surface that adds efficient anticoagulant property to the PDMS material. The surface modification is a simple and fast one-step process performed at neutral pH, optimal when working with closed microsystems. The heparin formed a uniform and functional coating on hydrophobic PDMS with comparatively high level of antithrombin-binding capacity. In addition, long-term studies revelaed that the immobilized heparin was more or less stable in the microchannels over a time of three weeks. Recalcified plasma in contact with native PDMS showed complete coagulation after 1 h, while no fibrin formation was detected in plasma incubated on heparin-coated PDMS within the same time. In conclusion, we see the heparin coating developed and evaluated in this study as a tool that greatly facilitates the use of PDMS in microfluidics dealing with plasma or blood samples.

HSV kategori
Identifikatorer
urn:nbn:se:uu:diva-95124 (URN)10.1016/j.colsurfb.2005.07.004 (DOI)
Tilgjengelig fra: 2006-11-17 Laget: 2006-11-17 Sist oppdatert: 2018-05-31bibliografisk kontrollert
3. Bioactive heparin immobilized onto microfluidic channels in poly(dimethylsiloxane) results in hydrophilic surface properties
Åpne denne publikasjonen i ny fane eller vindu >>Bioactive heparin immobilized onto microfluidic channels in poly(dimethylsiloxane) results in hydrophilic surface properties
Vise andre…
2005 (engelsk)Inngår i: Colloids and Surfaces B: Biointerfaces, ISSN 0927-7765, E-ISSN 1873-4367, Vol. 46, nr 4, s. 240-247Artikkel i tidsskrift (Fagfellevurdert) Published
HSV kategori
Identifikatorer
urn:nbn:se:uu:diva-95125 (URN)10.1016/j.colsurfb.2005.10.009 (DOI)
Tilgjengelig fra: 2006-11-17 Laget: 2006-11-17 Sist oppdatert: 2017-12-14bibliografisk kontrollert
4. Bioactivated PDMS microchannel evaluated as sensor for human CD4+ cells: The concept of a point-of-care method for HIV monitoring
Åpne denne publikasjonen i ny fane eller vindu >>Bioactivated PDMS microchannel evaluated as sensor for human CD4+ cells: The concept of a point-of-care method for HIV monitoring
Vise andre…
2007 (engelsk)Inngår i: Sensors and actuators. B, Chemical, ISSN 0925-4005, E-ISSN 1873-3077, Vol. 123, nr 2, s. 847-855Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Up to today, the number of CD4(+) lymphocytes remains the most important biological marker to determine the clinical stage of an HIV-infection. Analysis by flow cytometry, the standard method used today, is unsuitable in many developing countries, because of high costs involved and practical inconveniences. We here present the concept of an inexpensive PDMS-based point-of-care device for CD4(-)count. A simple fluorescence microscope for stained leucocytes counting is the only detection equipment needed. The biosensor surface consists of an initial heparin-based coating that adds hydrophilicity and thromboresistance to the PDMS material. The specific capturing chemistry is based on an avidin/biotin-antibody surface architecture. Pure capillary forces draw whole blood, as well as rinsing buffer, into the biosensor channel, minimizing the need of external equipment. Detection of the captured cells was performed by fluorescence imaging of HOECHST (stains cell nuclei) and CD3-FITC signals. It was shown that the non-specific adsorption of CD4(-) leucocytes was minimal to none. and the detection could therefore be done by only counting the easy identifiable HOECHST+ cells. Characterization of the biosensor coating process was additionally performed with the quartz crystal microbalance-dissipation technique.

Emneord
PDMS, poly(dimethylsiloxane), HIV, CD4-count, point-of-care
HSV kategori
Identifikatorer
urn:nbn:se:uu:diva-95126 (URN)10.1016/j.snb.2006.10.034 (DOI)000247060100029 ()
Tilgjengelig fra: 2006-11-17 Laget: 2006-11-17 Sist oppdatert: 2018-06-04bibliografisk kontrollert
5. Microfluidic PDMS-based sensor for CD4 cell count
Åpne denne publikasjonen i ny fane eller vindu >>Microfluidic PDMS-based sensor for CD4 cell count
Manuskript (Annet vitenskapelig)
Identifikatorer
urn:nbn:se:uu:diva-95127 (URN)
Tilgjengelig fra: 2006-11-17 Laget: 2006-11-17 Sist oppdatert: 2010-01-13bibliografisk kontrollert
6. A simplified method for capillary embedment into microfluidic devices exemplified by sol-gel based preconcentration
Åpne denne publikasjonen i ny fane eller vindu >>A simplified method for capillary embedment into microfluidic devices exemplified by sol-gel based preconcentration
2007 (engelsk)Inngår i: Electrophoresis, ISSN 0173-0835, E-ISSN 1522-2683, Vol. 28, nr 24, s. 4758-4764Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

We here describe an alternative method of embedding ftinctionalized capillaries into microdevices fabricated in PDMS. The capillaries have square-shaped outer dimensions and fit into elastic PDMS channel networks of similar dimensions. By modifying the capillary off-chip, the technique makes it possible to integrate a new chip function without risking contamination of already existing chemically patterned areas because of new reagent solutions. Leak-free insertion of these capillaries has earlier been reported, where a thin layer of uncured PDMS bonded the capillary to the microchannel and the lid structure. In this new approach, oxygen plasma is used to bond the square capillary to the PDMS, eliminating the risk of dogging the microsystem with uncured prepolymer. The new embedding technique was exemplified and evaluated by inserting a square capillary piece containing monolithic sol-gel for sample preconcentration application. The assembled microdevice was run with mass spectrometric detection, showing that peptides were preconcentrated without leakage from either the sol-gel itself or around the inserted capillary. Repeated preconcentration runs showed migration times better than 3% for all peptides. We believe that the presented microchip assembling technique greatly simplifies the insertion of functionalized capillary pieces, e.g., an initial preconcentrator to a PDMS device containing other downstream modules.

Emneord
microfluidics, PDMS, preconcentration, sol-gel
HSV kategori
Identifikatorer
urn:nbn:se:uu:diva-95128 (URN)10.1002/elps.200700221 (DOI)000252465600028 ()18008304 (PubMedID)
Tilgjengelig fra: 2006-11-17 Laget: 2006-11-17 Sist oppdatert: 2018-06-04bibliografisk kontrollert
7. Sample pretreatment on a microchip with an integrated electrospray emitter
Åpne denne publikasjonen i ny fane eller vindu >>Sample pretreatment on a microchip with an integrated electrospray emitter
Vise andre…
2006 (engelsk)Inngår i: Electrophoresis, ISSN 0173-0835, E-ISSN 1522-2683, Vol. 27, nr 11, s. 2075-2082Artikkel i tidsskrift (Fagfellevurdert) Published
Emneord
Electrospray emitter, Microchip, PDMS, Sample pretreatment
HSV kategori
Identifikatorer
urn:nbn:se:uu:diva-95129 (URN)10.1002/elps.200500763 (DOI)
Tilgjengelig fra: 2006-11-17 Laget: 2006-11-17 Sist oppdatert: 2017-12-14bibliografisk kontrollert
8. Electrokinetic-driven microfluidic system in poly(dimethylsiloxane) for mass spectrometry detection integrating sample injection, capillary electrophoresis, and electrospray emitter on-chip
Åpne denne publikasjonen i ny fane eller vindu >>Electrokinetic-driven microfluidic system in poly(dimethylsiloxane) for mass spectrometry detection integrating sample injection, capillary electrophoresis, and electrospray emitter on-chip
Vise andre…
2005 (engelsk)Inngår i: Electrophoresis, ISSN 0173-0835, E-ISSN 1522-2683, Vol. 26, nr 24, s. 4674-4683Artikkel i tidsskrift (Fagfellevurdert) Published
HSV kategori
Identifikatorer
urn:nbn:se:uu:diva-95130 (URN)10.1002/elps.200500338 (DOI)
Tilgjengelig fra: 2006-11-17 Laget: 2006-11-17 Sist oppdatert: 2025-04-07bibliografisk kontrollert
9. Instant oxidation of closed microchannels
Åpne denne publikasjonen i ny fane eller vindu >>Instant oxidation of closed microchannels
2007 (engelsk)Inngår i: Journal of Micromechanics and Microengineering, ISSN 0960-1317, E-ISSN 1361-6439, Vol. 17, nr 4, s. N16-N21Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A new method for instant oxidation of closed, bonded microchannels is presented and evaluated. By placing the tip-formed electrode of a corona plasma equipment in the reservoir of a PDMS microstructure, the plasma spark can spread into the microchannel and oxidize the inner PDMS channel walls. By applying this process, the non-specific adsorption of hydrophobic affinity analytes is markedly decreased, here evaluated with the fluorescent dye Rhodamine B and standard protein BSA. The results show that the surface adsorption in plasma-treated channels is reduced significantly, e.g. the amount of BSA adsorbed at 35 mm distance from the reservoir is only 35% of the amount of BSA adsorbed in non-treated channels. The surface shows very low adsorption during the first 200 min after oxidation, and has recovered (90%) its hydrophobicity first after 24 h. This method of instant surface oxidation has in our group been widely used to simplify microfluidic studies of microstructure prototypes, since the need of other more complicated surface modifications to lower analyte adsorption is eliminated.

Emneord
Hydrophobicity, Proteins, Hydrophobic compound, Adsorption, Plasma, Dimethylsiloxane polymer, Oxidation, Surface treatments, Fluidics, Microfluidics
HSV kategori
Identifikatorer
urn:nbn:se:uu:diva-95131 (URN)10.1088/0960-1317/17/4/N02 (DOI)000245434200030 ()
Tilgjengelig fra: 2006-11-17 Laget: 2006-11-17 Sist oppdatert: 2017-12-14bibliografisk kontrollert

Open Access i DiVA

fulltekst(1426 kB)5015 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1426 kBChecksum MD5
f6e171dcff9582c3bbac2b8f6e4bd5afcc6540c484cae9269fdb8c2521e022b4a8cad87a
Type fulltextMimetype application/pdf
omslag(564 kB)208 nedlastinger
Filinformasjon
Fil COVER01.pdfFilstørrelse 564 kBChecksum MD5
ac1755f2a9824c0f753dd86cd7039fc7db3872b5878cf947f7fecbd41d5111f58a11d9be
Type coverMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 5018 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 2830 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf