Logo: to the web site of Uppsala University

uu.sePublikasjoner fra Uppsala universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Resilience to storm conditions of power systems with large dependencies on offshore wind
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för elektroteknik, Elektricitetslära. Centre of Natural Hazards and Disaster Science (CNDS), Uppsala, Sweden.ORCID-id: 0000-0002-9868-0571
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för elektroteknik, Elektricitetslära.ORCID-id: 0000-0001-7828-8516
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för elektroteknik, Elektricitetslära. Centre of Natural Hazards and Disaster Science (CNDS), Uppsala, Sweden.ORCID-id: 0000-0002-8509-512X
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för elektroteknik, Elektricitetslära. Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Fysiska sektionen, Institutionen för fysik och astronomi, Teoretisk fysik. Centre of Natural Hazards and Disaster Science (CNDS), Uppsala, Sweden.ORCID-id: 0000-0001-9213-6447
2023 (engelsk)Inngår i: Journal of Physics, Conference Series, ISSN 1742-6588, E-ISSN 1742-6596, Vol. 2626, artikkel-id 012017Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The ongoing transition towards large installations of offshore wind and the electrification of the transport sector and other critical infrastructures introduce new vulnerabilities to the society. Large dependencies of power production from offshore wind are expected in the next decades, but there are large knowledge gaps regarding the power production reliability under severe weather conditions. Simultaneously, weather extremes may increase in frequency and intensity, driven by climate change. In this paper we investigate the resilience of a power system subject to a hurricane event. The power system is based on the IEEE39-bus New England system but with different scenarios for increasing penetration of offshore wind. We find that an offshore wind penetration level of 30% or less results in a power system resilient to hurricane events, with no need for load disconnection. However, when increased to 40% offshore wind penetration, 650 MW corresponding to 10% of the total load demand gets disconnected during the storm peak. With a penetration of 50% offshore wind, the disconnected load ranges from 2.2 GW of load corresponding to 1/3 of the total load demand, to a total power system blackout.

sted, utgiver, år, opplag, sider
Institute of Physics Publishing (IOPP), 2023. Vol. 2626, artikkel-id 012017
Emneord [en]
Extreme weather event, Offshore wind, Power system, Resilience
HSV kategori
Forskningsprogram
Elektroteknik med inriktning mot systemanalys
Identifikatorer
URN: urn:nbn:se:uu:diva-511045DOI: 10.1088/1742-6596/2626/1/012017ISI: 001147057400017OAI: oai:DiVA.org:uu-511045DiVA, id: diva2:1794875
Konferanse
EERA DeepWind Conference, January 18-20, 2023, Trondheim, Norway
Tilgjengelig fra: 2023-09-06 Laget: 2023-09-06 Sist oppdatert: 2024-03-27bibliografisk kontrollert
Inngår i avhandling
1. Power Grid Resilience to High Impact Low Probability Events
Åpne denne publikasjonen i ny fane eller vindu >>Power Grid Resilience to High Impact Low Probability Events
2023 (engelsk)Licentiatavhandling, med artikler (Annet vitenskapelig)
Abstract [en]

The electrification of societies and the decarbonisation of electricity production are changing energy systems worldwide. A fast transition towards the replacement of fossil fuels by intermittent renewable energy sources is expected in the next decades to combat climate change. A significant share of the produced electricity is likely to be generated from offshore wind farms, due to the abundant wind resources in the offshore regions and the lack of available onshore sites. However, increased electricity dependence in combination with expanded offshore wind power generation introduce new vulnerabilities to the society. Specifically, the effects of high impact low probability (HILP) events are considered as potential threats to the power system, not least because of the increasing number of extreme weather events. Therefore, research on power grid vulnerability and power system resilience to HILP events are of significant interest.

This thesis presents results of studies investigating power grid vulnerability from a topological perspective, and resilience to storm conditions of power systems with varying dependencies on offshore wind. To achieve this, methods based on complex network theory and AC power flow analysis have been developed, tested, and evaluated. Further, geospatial wind data from historical extreme storm events have been used to generate realistic power production profiles from hypothetical offshore wind farms.

The results strengthen that complex network concepts can be used successfully in the context of power grid vulnerability analysis. Further, the results show that the resilience of power systems with large dependencies on offshore wind differ vastly depending on the grid properties and control strategies, which are further discussed in this thesis.

sted, utgiver, år, opplag, sider
Uppsala: Uppsala University, 2023. s. 54
Emneord
Extreme weather, HILP events, offshore wind, power grid, resilience, vulnerability
HSV kategori
Forskningsprogram
Elektroteknik med inriktning mot systemanalys
Identifikatorer
urn:nbn:se:uu:diva-512049 (URN)
Presentation
2023-11-10, Evelyn Sokolowski, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 10:15 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2023-10-11 Laget: 2023-09-22 Sist oppdatert: 2024-06-17bibliografisk kontrollert

Open Access i DiVA

fulltext(1189 kB)406 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1189 kBChecksum SHA-512
ce450d86c67e7b043c122a9b0118ea7a7f3e43bea625851db0c6c1e67b01ecf14ec5fa66c70bb65738b705b45e121786b2698289fc0a181c6be31856086790e2
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekst

Person

Forsberg, SamuelThomas, KarinBergkvist, MikaelGöteman, Malin

Søk i DiVA

Av forfatter/redaktør
Forsberg, SamuelThomas, KarinBergkvist, MikaelGöteman, Malin
Av organisasjonen
I samme tidsskrift
Journal of Physics, Conference Series

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 408 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 194 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf