Logo: to the web site of Uppsala University

uu.sePublikasjoner fra Uppsala universitet
Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Microwave-based Safe Alternative for X-ray Scans for Pleural Effusion
IIEST Shibpur, Dept ETCE, Howrah, India..
IIEST Shibpur, Dept ETCE, Howrah, India..
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för elektroteknik, Fasta tillståndets elektronik.ORCID-id: 0000-0002-1092-6216
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för elektroteknik, Fasta tillståndets elektronik.ORCID-id: 0000-0002-2876-223X
2024 (engelsk)Inngår i: 2024 IEEE MICROWAVES, ANTENNAS, AND PROPAGATION CONFERENCE, MAPCON, Institute of Electrical and Electronics Engineers (IEEE), 2024Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Pleural effusion and high water content abnormality in the lungs require either continuous monitoring or frequent monitoring. Conventional techniques, such as X-ray scans, pose safety concerns due to their ionizing nature. In this work, we propose a methodology combining a wideband high-gain antenna with a raster scanning technique for imaging high water content anomalies within the lungs. The low-profile antenna operates over a wide bandwidth of 2.98 to 6 GHz, including the 5.8 GHz ISM band. Enhancements to the raster scanning technique have been made to improve resolution and accuracy. The proposed methodology has been applied on a multilayer tissue model. Additionally, a comparison between microwave imaging and X-ray scans is presented, demonstrating the potential of the proposed technique for safely and effectively detecting high water content abnormalities in the lungs.

sted, utgiver, år, opplag, sider
Institute of Electrical and Electronics Engineers (IEEE), 2024.
Emneord [en]
Artificial Magnetic Conductor, Low-profile antenna, Pleural Effusion, Raster scanning
HSV kategori
Identifikatorer
URN: urn:nbn:se:uu:diva-563481DOI: 10.1109/MAPCON61407.2024.10923042ISI: 001461196200115Scopus ID: 2-s2.0-105001880911ISBN: 979-8-3503-7970-9 (tryckt)ISBN: 979-8-3503-7969-3 (digital)OAI: oai:DiVA.org:uu-563481DiVA, id: diva2:1983061
Konferanse
2024 Microwaves Antennas and Propagation Conference, DEC 09-13, 2024, Hyderabad, INDIA
Forskningsfinansiär
VinnovaTilgjengelig fra: 2025-07-09 Laget: 2025-07-09 Sist oppdatert: 2025-07-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Mandal, BappadityaAugustine, Robin

Søk i DiVA

Av forfatter/redaktør
Mandal, BappadityaAugustine, Robin
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 20 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf