Logotyp: till Uppsala universitets webbplats

uu.sePublikationer från Uppsala universitet
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Hardware-in-the-Loop Volt-Watt and Volt-VAr Control for Distribution Systems with High Penetration of Renewables
Univ Fed Juiz de Fora, Multiplatform Simulat Lab, Elect Engn Program, BR-36036900 Juiz De Fora, MG, Brazil..
Univ Fed Juiz de Fora, Multiplatform Simulat Lab, Elect Engn Program, BR-36036900 Juiz De Fora, MG, Brazil..
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för elektroteknik, Elektricitetslära. Univ Fed Juiz de Fora, Multiplatform Simulat Lab, Elect Engn Program, BR-36036900 Juiz De Fora, MG, Brazil..ORCID-id: 0000-0002-4377-6445
2023 (Engelska)Ingår i: Journal of Control Automation and Electrical Systems, ISSN 2195-3880, Vol. 34, nr 1, s. 177-188Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

This work aims to validate in control hardware in the loop (CHIL) simulations new voltage profile control strategies in distribution systems with different levels of photovoltaic penetration. The proposed control is implemented through intelligent inverters with control functions that act through voltage sensitivity. The Volt-VAr (V-V) and Volt-Watt (V-W) functions act in the local voltage control being implemented in a complementary way. The simulations are performed in real time, using the real-time digital simulator. Residential load profiles, solar irradiance and temperature curves are discretized hourly over a daily period, with the intention of making the emulation more realistic. Voltage source converters were implemented in RSCAD software. The contribution of this article points to the performance of the Volt-Watt (V-W) control function in single-stage inverters, which allows the maximum generation of instantaneous active power, acting directly on the maximum power point tracking algorithm, this strategy being validated by the CHIL simulation. The results show that the Volt-VAr and Volt-Watt control functions, acting at different levels of photovoltaic penetration, were effective in preventing the voltage profiles from violating the critical level imposed by the regulatory standard. Leading to the conclusion that its implementation directly in photovoltaic inverters entails a low cost and a complementary solution for the new challenges of electrical systems.

Ort, förlag, år, upplaga, sidor
Springer Nature, 2023. Vol. 34, nr 1, s. 177-188
Nyckelord [en]
Voltage regulation, Smart inverters, RTDS, Control-hardware-in-the-loop, Volt-VAr and Volt-Watt
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:uu:diva-497014DOI: 10.1007/s40313-022-00954-7ISI: 000853286500002OAI: oai:DiVA.org:uu-497014DiVA, id: diva2:1739103
Tillgänglig från: 2023-02-23 Skapad: 2023-02-23 Senast uppdaterad: 2023-02-23Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Person

Oliveira, Janaína Goncalves de

Sök vidare i DiVA

Av författaren/redaktören
Oliveira, Janaína Goncalves de
Av organisationen
Elektricitetslära
Annan elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 218 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf