Dynamic Modeling of a Generator With Anisotropic Nonlinear Permanent Magnets in Finite Element Method Software
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för elektroteknik, Elektricitetslära.
Uppsala universitet, Teknisk-naturvetenskapliga vetenskapsområdet, Tekniska sektionen, Institutionen för elektroteknik, Elektricitetslära.ORCID-id: 0000-0001-8598-2565
2023 (Engelska)Ingår i: IEEE Transactions on Magnetics, ISSN 0018-9464, E-ISSN 1941-0069, Vol. 59, nr 9, artikel-id 7401308Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In this article, a method of dynamic modeling of nonlinear permanent magnets (PMs) with recoil lines in 2-D finite element analysis (FEA) software was presented. COMSOL Multiphysics 6.0 FEA software was used in this study. The method is implemented through the variable utilities. The simulation results of a spoke-type synchronous generator for a wind turbine with anisotropic aluminum-nickel-cobalt (Alnico) 5, 8B, and 9 grades were used to exemplify the model and compared. The proposed methodology can be used for the simulation of nonlinear PMs with recoil lines and includes reversible and irreversible losses of magnetization of nonlinear PMs. The effect of the magnetic field from the stator winding on nonlinear PMs during normal operation and short circuits was studied. The modeling results were compared to the model without any demagnetization and a previous study with recoil lines and averaged minimum magnetic flux points. The no-load (NL) voltages were compared before and after a demagnetization. The dynamic model showed considerable demagnetization of Alnico magnets during normal operational and three-phase short circuits. Alnico 5 and 9 showed higher sensitivity to short-circuit currents and the short-circuit currents caused remagnetization of the upper part of the magnet in the opposite direction. The anisotropy of the PM implemented in the model improved the magnetic field simulation inside the magnet and partially protected the magnet from demagnetization by inclined fields. At last, the method was experimentally verified by tests on an iron core.

Ort, förlag, år, upplaga, sidor
IEEE, 2023. Vol. 59, nr 9, artikel-id 7401308
Nyckelord [en]
Aluminum-nickel-cobalt (Alnico), COMSOL, demagnetization, finite element method (FEM), nonlinear permanent magnets (PM), PM synchronous generator (PMSG), recoil line
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:uu:diva-514058DOI: 10.1109/TMAG.2023.3296966ISI: 001061030600003OAI: oai:DiVA.org:uu-514058DiVA, id: diva2:1805362
Forskningsfinansiär
Vetenskapsrådet, 2018-04617Tillgänglig från: 2023-10-17 Skapad: 2023-10-17 Senast uppdaterad: 2024-04-22Bibliografiskt granskad
Ingår i avhandling
1. Nonlinear models of permanent magnets for electrical machines
Öppna denna publikation i ny flik eller fönster >>Nonlinear models of permanent magnets for electrical machines
2024 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

The increased demand for electricity, environmental problems related to mining of rare earth metals and to usage of fossil fuels, national security issues, and monopolization of the rare earth metals market forcing society to explore alternative options for conventional rare earth permanent magnets. Generally, the relationship between magnetic flux density and the magnetic field of permanent magnets has a nonlinear shape, but the operating region of conventional permanent magnets is linear. There is no convenient model of permanent magnets in existing commercial finite element method software that models partial demagnetization and remagnetization of nonlinear permanent magnets correctly. This thesis presents a model that is able to model an electrical machine with nonlinear permanent magnets and does not require a large computational power. A gradual improvement of the model resulted in four versions of it. It started with a simple linear model and ended with a model that is able to simulate partial demagnetization and remagnetization of the magnet and includes all four quadrants of the BH loop. Also, the last version limits the maximum magnetization depending on the angle of normalized magnetization. The magnetic characteristics of Alnico 8 LNGT40 and Alnico 9 LNGT72 magnets were measured in a vibrating sample magnetometer in order to obtain the material data required for this research work. A mathematical model of the MH loops of Alnico 8 LNGT40 in different directions was developed. The models of a synchronous permanent magnet generator with a spoke type topology with Alnico 5, 8 and 9 magnets were tested under normal and three phase short circuit conditions. The results were compared and discussed. It is found Alnico 5 is more sensitive to short circuit than Alnico 8 and 9. Electric steel clamps holding the permanent magnets and airgap above the magnets protect them from demagnetization.

Ort, förlag, år, upplaga, sidor
Uppsala: Acta Universitatis Upsaliensis, 2024. s. 62
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 2404
Nyckelord
Aluminum-nickel-cobalt (Alnico), COMSOL, demagnetization, finite element method (FEM), nonlinear permanent magnets, permanent magnet synchronous generator (PMSG), recoil line
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
urn:nbn:se:uu:diva-527007 (URN)978-91-513-2136-3 (ISBN)
Disputation
2024-06-13, Room 80101, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 13:15 (Engelska)
Opponent
Handledare
Forskningsfinansiär
Vetenskapsrådet, 2018-04617
Tillgänglig från: 2024-05-20 Skapad: 2024-04-22 Senast uppdaterad: 2024-05-23

Open Access i DiVA

fulltext(1806 kB)219 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1806 kBChecksumma SHA-512
61b1606eaf736182b78add3c6426b29be1b29728afd29603dcb17da3603fdef865b8cf2cba98b4707c860971d3d0a84c7f19b2ccb48ce261cd53ff098c103cb5
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltext

Person

Ibrayeva, AnarEriksson, Sandra

Sök vidare i DiVA

Av författaren/redaktören
Ibrayeva, AnarEriksson, Sandra
Av organisationen
Elektricitetslära
I samma tidskrift
IEEE Transactions on Magnetics
Annan elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 219 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 287 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf