Logotyp: till Uppsala universitets webbplats

uu.sePublikationer från Uppsala universitet
Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A novel algorithm to determine ventilation parameters during cardiopulmonary resuscitation using pneumotachography waveform data
Uppsala universitet, Medicinska och farmaceutiska vetenskapsområdet, Medicinska fakulteten, Institutionen för kirurgiska vetenskaper, Anestesiologi och intensivvård.ORCID-id: 0000-0003-4289-8202
Visa övriga samt affilieringar
2026 (Engelska)Ingår i: Resuscitation Plus, E-ISSN 2666-5204, Vol. 28, artikel-id 101238Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Background

A major barrier to the analysis of ventilation waveform data collected during CPR is the presence of artefacts caused by chest compressions. This study describes the development and evaluation of an algorithm to extract parameters regarding ventilation volume, pressure, and frequency from pneumotachography waveform data collected during ongoing simulated CPR.

Method

Ventilation waveform data was collected from a pneumotachograph connected to the respiratory circuit of a ventilator and a test lung. Both regular ventilation and ventilation during simulated CPR were used to develop the algorithm. A grid search was employed to optimize the algorithm parameters compared to the ventilator settings. The parameters were then manually tuned using clinical data from ventilation during CPR. The performance of the algorithm was described in terms of the median error vs. the known ventilator settings in the simulated data.

Results

Compared to the ventilator settings, the largest systematic errors of the algorithm was an overestimation of peak pressures during asynchronous CPR (median error of 3 (IQR 0.3–5.8) cmH2O), and an underestimation of inspiratory volumes during synchronous CPR (median error 46 (IQR −76 to 10) ml).

Conclusion

In an experimental setting, the developed algorithm provides a novel solution to measure ventilation parameters during ongoing chest compressions. The algorithm is freely available under an open-source licence for use and further development. Further studies will be needed to validate the algorithm.

Ort, förlag, år, upplaga, sidor
Elsevier, 2026. Vol. 28, artikel-id 101238
Nationell ämneskategori
Anestesi och intensivvård
Forskningsämne
Medicinsk vetenskap
Identifikatorer
URN: urn:nbn:se:uu:diva-581580DOI: 10.1016/j.resplu.2026.101238ISI: 001683628700001PubMedID: 41674708Scopus ID: 2-s2.0-105029311455OAI: oai:DiVA.org:uu-581580DiVA, id: diva2:2043686
Tillgänglig från: 2026-03-05 Skapad: 2026-03-05 Senast uppdaterad: 2026-03-16Bibliografiskt granskad
Ingår i avhandling
1. Exploring ventilation during cardiopulmonary resuscitation: Experimental and clinical insights
Öppna denna publikation i ny flik eller fönster >>Exploring ventilation during cardiopulmonary resuscitation: Experimental and clinical insights
2026 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Ventilation during cardiopulmonary resuscitation remains understudied with current guideline recommendations for the treatment relying on low level evidence and expert opinion. The aim of this doctoral project was to explore ventilation during cardiopulmonary resuscitation, both in the experimental and clinical setting.

Study I investigated whether a suction cup on a mechanical chest compression device intended to assist chest recoil affected the haemodynamics and ventilation in an experimental porcine model. No difference in EtCO2, as a measurement of cardiac output, or ventilation could be found, although the suction cup increased the coronary perfusion pressure.

In study II, ventilation parameters, haemodynamics, blood gases and lung injuries were compared between ventilation during continuous chest compressions and ventilations given during a pause of the chest compressions (30:2) in an experimental porcine model. Continuous chest compressions were associated with higher peak inspiratory pressure, lower EtCO2 and PaCO2. No differences were found with regards to lung injuries between the groups.

Study III aimed to develop and test a novel algorithm designed to extract accurate ventilation parameters from ventilation waveform signals, gathered during experimental CPR, in the presence of chest compression artefacts in the signal, that otherwise interferes with the parameter extraction. The algorithm was tested with a pneumotacography device and with mechanical ventilators giving ventilation parameters with known values. The algorithm deviated only slightly from the ventilator settings and outperformed the standard software of the pneumotachograph.

Study IV was an observational multicentre study that aimed to describe ventilation parameters during cardiopulmonary resuscitation. Patients were included from five sites, four out of hospital and one in hospital. Included in the study were 241 patients and 28120 ventilations. The ventilations were heterogenous and varied with airway modality and ventilation mode. Bag-valve-mask ventilations were associated with large levels of leakage and asynchronous ventilations with endotracheal tubes with high airway pressures. No obvious signs of hyperventilation were found.

Future research on cardiopulmonary resuscitation should when possible include measurements of ventilation, in order to deduce if the varying ventilation parameters affects outcomes and to decide optimal ventilation strategies for survival.

Ort, förlag, år, upplaga, sidor
Uppsala: Acta Universitatis Upsaliensis, 2026. s. 99
Serie
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, ISSN 1651-6206 ; 2244
Nyckelord
Cardiac arrest, cardiopulmonary resuscitation, ventilation, ventilation parameters, advanced life support
Nationell ämneskategori
Anestesi och intensivvård
Forskningsämne
Medicinsk vetenskap
Identifikatorer
urn:nbn:se:uu:diva-581885 (URN)978-91-513-2773-0 (ISBN)
Disputation
2026-05-08, H:son Holmdahlsalen, Akademiska sjukhuset ing 100, Dag Hammarskjölds väg 8, Uppsala, 13:00 (Svenska)
Opponent
Handledare
Tillgänglig från: 2026-04-17 Skapad: 2026-03-16 Senast uppdaterad: 2026-04-17

Open Access i DiVA

fulltext(1349 kB)67 nedladdningar
Filinformation
Filnamn FULLTEXT02.pdfFilstorlek 1349 kBChecksumma SHA-512
7c51d464ef697cf071c5f6f0017a613c2eec1380cb788be3a445515faf7bfad5f9220a3301d58df324c25d869ccac725acea2f1bb97910b5be08cb0bc0ee559a
Typ fulltextMimetyp application/pdf

Övriga länkar

Förlagets fulltextPubMedScopus

Person

Mälberg, JohanSmekal, DavidRubertsson, StenSpangler, Douglas

Sök vidare i DiVA

Av författaren/redaktören
Mälberg, JohanSmekal, DavidRubertsson, StenSpangler, Douglas
Av organisationen
Anestesiologi och intensivvård
I samma tidskrift
Resuscitation Plus
Anestesi och intensivvård

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 67 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 2694 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf