Logo: to the web site of Uppsala University

uu.sePublications from Uppsala University
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
One single, fast and robust capillary electrophoresis method for the direct quantification of intact adenovirus particles in upstream and downstream processing samples
Janssen Vaccines & Prevent BV, Pharmaceut & Analyt Dev, Newtonweg 1, NL-2333 CP Leiden, Netherlands..
Janssen Vaccines & Prevent BV, Pharmaceut & Analyt Dev, Newtonweg 1, NL-2333 CP Leiden, Netherlands..
Janssen Vaccines & Prevent BV, Pharmaceut & Analyt Dev, Newtonweg 1, NL-2333 CP Leiden, Netherlands..
Janssen Vaccines & Prevent BV, Pharmaceut & Analyt Dev, Newtonweg 1, NL-2333 CP Leiden, Netherlands..
Show others and affiliations
2017 (English)In: Talanta: The International Journal of Pure and Applied Analytical Chemistry, ISSN 0039-9140, E-ISSN 1873-3573, Vol. 166, p. 8-14Article in journal (Refereed) Published
Abstract [en]

During development of adenovirus-based vaccines, samples have to be analyzed in order to either monitor the production process or control the quality and safety of the product. An important quality attribute is the total concentration of intact adenoviruses, which currently is determined by quantitative polymerase chain reaction (qPCR) or anion exchange-HPLC. Capillary Electrophoresis (CE) was evaluated as alternative to the current methods with the aim to have one single method that allows reliable and fast quantification of adenovirus particles throughout the full process. Intact adenoviruses samples from downstream processing and upstream processing were analyzed directly by CE with UV-detection at 214 nm. Only the samples with high amounts of DNA required a simple sample pretreatment by benzonase. Adenovirus particles were separated from matrix components such as cell debris, residual cell DNA, and/or proteins on a PVA-coated capillary using a BGE consisting of 125 mM Tris, 338 mM tricine and 0.2% v/v polysorbate-20 at pH 7.7. Full factorial design of experiments was used for method optimization as part of the analytical quality by design (AQbD) method development approach. The method was validated for the quantification of adenoviruses on five representative samples from the manufacturing process in the range of 0.5 x10(11)-1.5 x10(11) adenovirus particles per ml (similar to 80 to 250 pmo1/1). The CE method showed intermediate precision of 7.8% RSD on concentration and an accuracy (spiked recovery) of 95-110%. CE proved highly useful for process development support and is being implemented for in-process control testing for adenovirus vaccine manufacturing.

Place, publisher, year, edition, pages
2017. Vol. 166, p. 8-14
Keywords [en]
Analytical Quality by Design, Capillary electrophoresis, Intact adenoviruses, Quantification, Upstream and downstream processing
National Category
Analytical Chemistry Pharmaceutical Sciences
Identifiers
URN: urn:nbn:se:uu:diva-313285DOI: 10.1016/j.talanta.2017.01.013ISI: 000395839700002PubMedID: 28213262OAI: oai:DiVA.org:uu-313285DiVA, id: diva2:1066561
Available from: 2017-01-18 Created: 2017-01-18 Last updated: 2022-09-26Bibliographically approved
In thesis
1. Analytical Quality by Design Method Development for Vaccine Characterization
Open this publication in new window or tab >>Analytical Quality by Design Method Development for Vaccine Characterization
2022 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Vaccines that are safe, efficacious, and can be rapidly developed are needed to prevent and to react to emerging global infectious disease threats such as influenza, Polio, and Coronavirus diseases. Fast and reliable analytical methods are required without delay to support vaccine process and product development, characterization, and quality control testing. The traditional analytical methods for vaccines are laborious and often lack analytical power, causing slow, expensive, or sometimes failing vaccine development. Capillary electrophoresis (CE) is a technique that has great potential for biopharmaceutical analysis, although there has been limited application in vaccine development.

Several novel CE methods were explored, developed, and applied for viral vaccine analysis, making use of the analytical quality by design (AQbD) process and tools. AQbD is a framework of science- and risk-based decision making to achieve in-depth method understanding and to set up fit-for-purpose and in-control analytical methods. 

Commercial kits for capillary gel electrophoresis (CGE) and imaging capillary isoelectric focusing (icIEF) for antibodies analysis were applied and improved for vaccine analysis. Analytical mechanisms were studied, such as the effect of gel buffer composition on separation, and an AQbD CGE method development strategy was established. The strategy was successfully applied to develop CGE methods for the analysis of seasonal and universal influenza, and sabin inactivated polio vaccine proteins. An icIEF method was also developed, validated, and applied for the universal influenza vaccine protein. 

A capillary zone electrophoresis (CZE) method development for intact adenovirus concentration determination started with background electrolyte (BGE) and capillary design and screening. An BGE with tris and tricine and a neutral capillary resulted in optimal and robust separation and limited adsorption. The CZE method was validated for seed release, in-process control, product release, and stability testing. The precise, accurate, fast, and robust CZE method was applied for all process intermediates and used at different locations. Process impurities and product degradation could also be characterized.

Additionally, CZE methods for chloride and bromide analysis in complex matrices, and a CGE method for host cell DNA characterization were developed for characterization as well as to support process development.

Development of CE methods using AQbD reduced lead times and costs. The developed CE methods were easier to use, were more accurate and precise, and were more selective for product and process impurities compared to the previously used analytical methods for vaccines. The use of CE and AQbD helped improve on vaccine safety, efficacy, and quality.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2022. p. 89
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Pharmacy, ISSN 1651-6192 ; 319
Keywords
viral vaccines, adenovirus, influenza, polio, COVID, corona, capillary electrophoresis, analytical quality by design, analytical method development, CGE, icIEF, CZE, crude cell suspension analysis, in-process sample analysis, quality control testing, biopharmaceutical characterization
National Category
Analytical Chemistry
Research subject
Analytical Pharmaceutical Chemistry
Identifiers
urn:nbn:se:uu:diva-483007 (URN)978-91-513-1618-5 (ISBN)
Public defence
2022-11-15, Room A1:107a, BMC, Husargatan 3, Uppsala, 09:15 (English)
Opponent
Supervisors
Available from: 2022-10-24 Created: 2022-09-26 Last updated: 2022-10-24

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records

Geurink, LarsSänger - van de Griend, Cari

Search in DiVA

By author/editor
Geurink, LarsSänger - van de Griend, Cari
By organisation
Analytical Pharmaceutical Chemistry
In the same journal
Talanta: The International Journal of Pure and Applied Analytical Chemistry
Analytical ChemistryPharmaceutical Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 623 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf