MAS: Standalone Microwave Resonator to Assess Muscle Quality
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Electrical Engineering, Solid-State Electronics.ORCID iD: 0000-0001-8065-0094
Maastricht Univ, Dept Traumatol, Med Ctr, NL-6229 HX Maastricht, Netherlands..
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Electrical Engineering, Solid-State Electronics.ORCID iD: 0000-0002-1092-6216
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Electrical Engineering, Solid-State Electronics.ORCID iD: 0000-0003-4821-8087
Show others and affiliations
2021 (English)In: Sensors, E-ISSN 1424-8220, Vol. 21, no 16, article id 5485Article in journal (Refereed) Published
Abstract [en]

Microwave-based sensing for tissue analysis is recently gaining interest due to advantages such as non-ionizing radiation and non-invasiveness. We have developed a set of transmission sensors for microwave-based real-time sensing to quantify muscle mass and quality. In connection, we verified the sensors by 3D simulations, tested them in a laboratory on a homogeneous three-layer tissue model, and collected pilot clinical data in 20 patients and 25 healthy volunteers. This report focuses on initial sensor designs for the Muscle Analyzer System (MAS), their simulation, laboratory trials and clinical trials followed by developing three new sensors and their performance comparison. In the clinical studies, correlation studies were done to compare MAS performance with other clinical standards, specifically the skeletal muscle index, for muscle mass quantification. The results showed limited signal penetration depth for the Split Ring Resonator (SRR) sensor. New sensors were designed incorporating Substrate Integrated Waveguides (SIW) and a bandstop filter to overcome this problem. The sensors were validated through 3D simulations in which they showed increased penetration depth through tissue when compared to the SRR. The second-generation sensors offer higher penetration depth which will improve clinical data collection and validation. The bandstop filter is fabricated and studied in a group of volunteers, showing more reliable data that warrants further continuation of this development.

Place, publisher, year, edition, pages
MDPI AG MDPI, 2021. Vol. 21, no 16, article id 5485
Keywords [en]
muscle quality, sarcopenia, microwave sensing, bandstop filter, substrate integrated waveguides
National Category
Medical Laboratory Technologies
Identifiers
URN: urn:nbn:se:uu:diva-455509DOI: 10.3390/s21165485ISI: 000690024700001PubMedID: 34450927OAI: oai:DiVA.org:uu-455509DiVA, id: diva2:1601209
Available from: 2021-10-07 Created: 2021-10-07 Last updated: 2025-02-09Bibliographically approved
In thesis
1. Evaluation of biomedical microwave sensors: Microwave sensors as muscle quality discriminators in laboratory and pilot clinical trial settings
Open this publication in new window or tab >>Evaluation of biomedical microwave sensors: Microwave sensors as muscle quality discriminators in laboratory and pilot clinical trial settings
2022 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

In this thesis the primary focus is on the evaluation of biomedical microwave sensor to be used in the muscle analyzer system. Lower muscle quality is one indicator that a patient can have sarcopenia. Therefore the muscle analyzer system can be a tool used in screening for sarcopenia. Sarcopenia is a progressive skeletal muscle disorder that typically affects elderly people. It is characterized by several different things, one of them is that there is an infiltration of fat into the muscle. At microwave frequencies the dielectric properties of fat are vastly different than the muscles. So, this fat infiltration creates a dielectric contrast compared to muscle without this fat infiltration that the sensors aim to detect.

The muscle analyzer system is proposed to be a portable device that can be employed in clinics to assess muscle quality. The sensors are evaluated on their ability to distinguish between normal muscle tissue and muscle of lower quality. This is achieved via electromagnetic simulations, clinical trials, where the system is compared against established techniques, and phantom experiments, where artificial tissue emulating materials is used in a laboratory setting to mimick the properties of human tissues.

In a initial clinical pilot study the split ring resonator sensor was used, but the results raised concerns over the penetration depth of the sensor. Therefore, three new alternative sensors were designed and evaluated via simulations. Two of the new sensors showed encouraging results, one of which has been fabricated. This sensor was used in a another clinical study.This study only had data from 4 patients, 8 measurements in total, meaning it was hard to draw any conclusions from it. The sensors used in the clinical setting as well as another were evaluated in the phantom experiments. Those experiments were exploratory because a wider frequency range was used, although some problems in the experiments were found.

A secondary approach in this thesis is devoted to a data-driven approach, where a microwave sensor is simulated. The data from it is simulated and used to train a neural network to predict the dielectric properties of materials. The network predicts these properties with relatively high accuracy. However, this approach is currently limited to simulations only. Several ideas on how to improve this approach and extend it to measurements is given.

Publisher
p. 75
Keywords
Microwave sensors, Sarcopenia, Muscle quality assessment, Biomedical applications, Tissue dielectric properties, Data-driven modelling, Clinical trials, EM Simulations, Phantom experiments
National Category
Medical Instrumentation Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Engineering Science with specialization in Electronics
Identifiers
urn:nbn:se:uu:diva-466137 (URN)
Presentation
2022-03-31, Heinz-Otto Kreiss, 101195, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 09:15 (English)
Opponent
Supervisors
Available from: 2022-03-09 Created: 2022-02-09 Last updated: 2025-02-10
2. Data-Driven Methods for Microwave Sensor Devices in Musculoskeletal Diagnostics
Open this publication in new window or tab >>Data-Driven Methods for Microwave Sensor Devices in Musculoskeletal Diagnostics
2024 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Microwave sensors can be used within medicine as they use non-ionizing radiation, are often low cost, and can be designed for a specific purpose. The application of microwave sensors for diagnostics and monitoring can be improved using appropriate data analysis. The multi-layered structure of the human body makes the measurements on people complex. A tremendous effort is required to create an analytical model of the body. In this context a data-driven approach, building a model that learns from previous measurements, is more suitable to analyze the data. This thesis aims to address statistical and data-driven approaches based on microwave sensor data for biomedical applications.

A significant part of this thesis deals with microwave sensors for assessing muscle quality. It details the progress from initial clinical campaign to the creation of a machine learning algorithm to assess the local body composition. Such a device would be suitable for screening age-related muscle disorders like sarcopenia and muscle atrophy. Statistical analysis following the initial clinical campaign revealed no significant differences in the microwave data. Therefore, new sensor designs were evaluated. The most promising sensor was used in a small clinical campaign where it was able to detect a change in muscle size for one patient with multiple measurements over time. Successive measurements followed on tissue emulating phantoms and volunteers. For data analysis a machine learning algorithm was designed to predict the skin, fat, and muscle properties. This changes the aim from assessing muscle quality to assessing local body composition. For phantom data the algorithm was accurate for skin and fat and for volunteer data for fat and muscle. Crucially, the algorithm also performed better with more data available, meaning that results should improve if more data is collected.

Microwave sensors have also been employed to assess bone. The first of two applications was to monitor the bone healing progression post surgery treating craniosynostosis. No substantial conclusions could be drawn from the statistical analysis most likely due to measurement uncertainties. The second application used a purpose-built setup for controlled measurements in ex vivo bone samples submerged in liquid, to simulate an in vivo environment. The purpose was to estimate the dielectric properties of bone. The derived bone properties were lower than expected, probably due to air trapped inside the sample.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2024. p. 93
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 2359
Keywords
Machine Learning, Microwave Sensors, Data-Driven Modeling, Statistical Analysis, Maskininlärning, Mikrovågssensorer, Datadriven modellering, Statistisk Analys
National Category
Signal Processing Other Computer and Information Science Other Medical Engineering
Research subject
Engineering Science with specialization in Electronics
Identifiers
urn:nbn:se:uu:diva-521537 (URN)978-91-513-2021-2 (ISBN)
Public defence
2024-03-15, lecture room Heinz-Otto Kreiss, Lägerhyddsvägen 1, Uppsala, 09:00 (English)
Opponent
Supervisors
Available from: 2024-02-20 Created: 2024-01-25 Last updated: 2026-06-01

Open Access in DiVA

fulltext(6061 kB)588 downloads
File information
File name FULLTEXT01.pdfFile size 6061 kBChecksum SHA-512
cb12bb64f71f46af3a9a9cbe12859e41e4488dfe5e97916e0635e9e14512854c1c5491514210200bc5e05a109602d3d31b6049471afc44c78de1ef05db47d643
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Authority records

Mattsson, ViktorMandal, BappadityaPerez, Mauricio D.Augustine, Robin

Search in DiVA

By author/editor
Mattsson, ViktorMandal, BappadityaPerez, Mauricio D.Augustine, Robin
By organisation
Solid-State Electronics
In the same journal
Sensors
Medical Laboratory Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 600 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 683 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf