Muscle Analyzer System: Exploring Correlation Between Novel Microwave Resonator and Ultrasound-based Tissue Information in the Thigh
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Electrical Engineering, Solid-State Electronics. (Microwaves in Medical Engineering)ORCID iD: 0000-0001-8065-0094
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Electrical Engineering, Solid-State Electronics. (Microwaves in Medical Engineering)ORCID iD: 0000-0003-4821-8087
Show others and affiliations
2022 (English)In: 2022 16th European Conference on Antennas and Propagation (EuCAP), Institute of Electrical and Electronics Engineers (IEEE), 2022, article id 9769216Conference paper, Published paper (Refereed)
Abstract [en]

A microwave sensor to safely measure quality of muscle tissue for diagnosis and screening of diseases and medical conditions characterized by fat infiltration in muscle is presented. Fat infiltration in muscle may be seen by a lower dielectric constant of muscle at microwave frequencies corresponding to the large contrast between fat and muscle tissues. A planar resonator based on a bandstop filter and optimized to noninvasively interrogate muscle in the thigh on tissue quality is proposed. Currently, a study based on clinical trials is carried out, and, here, we present a preliminary correlation between skin and fat thicknesses and rectus femoris cross sectional area (CSA) measured with ultrasound and the proposed sensor's resonance frequency. CST simulations based on the ultrasound information guide the analysis. We see that although there are signs of a potential correlation between CSA and resonance, skin and fat variability is still an issue to overcome.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers (IEEE), 2022. article id 9769216
Keywords [en]
Sensors, Muscle Quality, Bandstop Filter, Clinical Measurements
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering Medical Instrumentation
Identifiers
URN: urn:nbn:se:uu:diva-466134DOI: 10.23919/EuCAP53622.2022.9769216ISI: 000815113901017ISBN: 978-88-31299-04-6 (electronic)ISBN: 978-1-6654-1604-7 (print)OAI: oai:DiVA.org:uu-466134DiVA, id: diva2:1631625
Conference
16th European Conference on Antennas and Propagation (EuCAP) 2022, 27 March-1 April, Madrid, Spain
Available from: 2022-01-24 Created: 2022-01-24 Last updated: 2026-09-18Bibliographically approved
In thesis
1. Evaluation of biomedical microwave sensors: Microwave sensors as muscle quality discriminators in laboratory and pilot clinical trial settings
Open this publication in new window or tab >>Evaluation of biomedical microwave sensors: Microwave sensors as muscle quality discriminators in laboratory and pilot clinical trial settings
2022 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

In this thesis the primary focus is on the evaluation of biomedical microwave sensor to be used in the muscle analyzer system. Lower muscle quality is one indicator that a patient can have sarcopenia. Therefore the muscle analyzer system can be a tool used in screening for sarcopenia. Sarcopenia is a progressive skeletal muscle disorder that typically affects elderly people. It is characterized by several different things, one of them is that there is an infiltration of fat into the muscle. At microwave frequencies the dielectric properties of fat are vastly different than the muscles. So, this fat infiltration creates a dielectric contrast compared to muscle without this fat infiltration that the sensors aim to detect.

The muscle analyzer system is proposed to be a portable device that can be employed in clinics to assess muscle quality. The sensors are evaluated on their ability to distinguish between normal muscle tissue and muscle of lower quality. This is achieved via electromagnetic simulations, clinical trials, where the system is compared against established techniques, and phantom experiments, where artificial tissue emulating materials is used in a laboratory setting to mimick the properties of human tissues.

In a initial clinical pilot study the split ring resonator sensor was used, but the results raised concerns over the penetration depth of the sensor. Therefore, three new alternative sensors were designed and evaluated via simulations. Two of the new sensors showed encouraging results, one of which has been fabricated. This sensor was used in a another clinical study.This study only had data from 4 patients, 8 measurements in total, meaning it was hard to draw any conclusions from it. The sensors used in the clinical setting as well as another were evaluated in the phantom experiments. Those experiments were exploratory because a wider frequency range was used, although some problems in the experiments were found.

A secondary approach in this thesis is devoted to a data-driven approach, where a microwave sensor is simulated. The data from it is simulated and used to train a neural network to predict the dielectric properties of materials. The network predicts these properties with relatively high accuracy. However, this approach is currently limited to simulations only. Several ideas on how to improve this approach and extend it to measurements is given.

Publisher
p. 75
Keywords
Microwave sensors, Sarcopenia, Muscle quality assessment, Biomedical applications, Tissue dielectric properties, Data-driven modelling, Clinical trials, EM Simulations, Phantom experiments
National Category
Medical Instrumentation Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Engineering Science with specialization in Electronics
Identifiers
urn:nbn:se:uu:diva-466137 (URN)
Presentation
2022-03-31, Heinz-Otto Kreiss, 101195, Ångströmlaboratoriet, Lägerhyddsvägen 1, Uppsala, 09:15 (English)
Opponent
Supervisors
Available from: 2022-03-09 Created: 2022-02-09 Last updated: 2025-02-10
2. Data-Driven Methods for Microwave Sensor Devices in Musculoskeletal Diagnostics
Open this publication in new window or tab >>Data-Driven Methods for Microwave Sensor Devices in Musculoskeletal Diagnostics
2024 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Microwave sensors can be used within medicine as they use non-ionizing radiation, are often low cost, and can be designed for a specific purpose. The application of microwave sensors for diagnostics and monitoring can be improved using appropriate data analysis. The multi-layered structure of the human body makes the measurements on people complex. A tremendous effort is required to create an analytical model of the body. In this context a data-driven approach, building a model that learns from previous measurements, is more suitable to analyze the data. This thesis aims to address statistical and data-driven approaches based on microwave sensor data for biomedical applications.

A significant part of this thesis deals with microwave sensors for assessing muscle quality. It details the progress from initial clinical campaign to the creation of a machine learning algorithm to assess the local body composition. Such a device would be suitable for screening age-related muscle disorders like sarcopenia and muscle atrophy. Statistical analysis following the initial clinical campaign revealed no significant differences in the microwave data. Therefore, new sensor designs were evaluated. The most promising sensor was used in a small clinical campaign where it was able to detect a change in muscle size for one patient with multiple measurements over time. Successive measurements followed on tissue emulating phantoms and volunteers. For data analysis a machine learning algorithm was designed to predict the skin, fat, and muscle properties. This changes the aim from assessing muscle quality to assessing local body composition. For phantom data the algorithm was accurate for skin and fat and for volunteer data for fat and muscle. Crucially, the algorithm also performed better with more data available, meaning that results should improve if more data is collected.

Microwave sensors have also been employed to assess bone. The first of two applications was to monitor the bone healing progression post surgery treating craniosynostosis. No substantial conclusions could be drawn from the statistical analysis most likely due to measurement uncertainties. The second application used a purpose-built setup for controlled measurements in ex vivo bone samples submerged in liquid, to simulate an in vivo environment. The purpose was to estimate the dielectric properties of bone. The derived bone properties were lower than expected, probably due to air trapped inside the sample.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2024. p. 93
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 2359
Keywords
Machine Learning, Microwave Sensors, Data-Driven Modeling, Statistical Analysis, Maskininlärning, Mikrovågssensorer, Datadriven modellering, Statistisk Analys
National Category
Signal Processing Other Computer and Information Science Other Medical Engineering
Research subject
Engineering Science with specialization in Electronics
Identifiers
urn:nbn:se:uu:diva-521537 (URN)978-91-513-2021-2 (ISBN)
Public defence
2024-03-15, lecture room Heinz-Otto Kreiss, Lägerhyddsvägen 1, Uppsala, 09:00 (English)
Opponent
Supervisors
Available from: 2024-02-20 Created: 2024-01-25 Last updated: 2026-06-01

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Mattsson, ViktorPérez, Mauricio D.Mandal, BappadityaAugustine, Robin

Search in DiVA

By author/editor
Mattsson, ViktorPérez, Mauricio D.Mandal, BappadityaAugustine, Robin
By organisation
Solid-State Electronics
Other Electrical Engineering, Electronic Engineering, Information EngineeringMedical Instrumentation

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 421 hits
CiteExportLink to record
Permanent link