Suction cup on a piston-based chest compression device improves coronary perfusion pressure and cerebral oxygenation during experimental cardiopulmonary resuscitation
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Anaesthesiology and Intensive Care. Uppsala Univ Hosp, Emergency Med Serv EMS, Sjukhusvagen, S-75185 Uppsala, Sweden..ORCID iD: 0000-0003-4289-8202
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Anaesthesiology and Intensive Care. Uppsala Univ Hosp, Emergency Med Serv EMS, Sjukhusvagen, S-75185 Uppsala, Sweden..ORCID iD: 0000-0002-3563-6450
Jolife Stryker AB, S-23633 Scheelevagen, Sweden..
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Anaesthesiology and Intensive Care, Hedenstierna laboratory.ORCID iD: 0000-0002-1976-4129
Show others and affiliations
2022 (English)In: Resuscitation Plus, E-ISSN 2666-5204, Vol. 12, article id 100311Article in journal (Refereed) Published
Abstract [en]

Introduction: The presented study aimed to investigate whether a mechanical chest compression piston device with a suction cup assisting chest recoil could impact the hemodynamic status when compared to a bare piston during cardiopulmonary resuscitation.

Methods: 16 piglets were anesthetized and randomized into 2 groups. After 3 minutes of induced ventricular fibrillation, a LUCAS 3 device was used to perform chest compressions, in one group a suction cup was mounted on the device's piston, while in the other group, compressions were per -formed by the bare piston. The device was used in 30:2 mode and the animals were manually ventilated. Endpoints of the study were: end tidal carbon dioxide, coronary and cerebral perfusion pressures, and brain oxygenation (measured using near infrared spectroscopy). At the end of the protocol, the animals that got a return to spontaneous circulation were observed for 60 minutes, then euthanized.

Results: No difference was found in end tidal carbon dioxide or tidal volumes. Coronary perfusion pressure and cerebral oxygenation were higher in the Suction cup group over the entire experiment time, while cerebral perfusion pressure was higher only in the last 5 minutes of CPR. A passive tidal volume (air going in and out the airways during compressions) was detected and found correlated to end tidal carbon dioxide.

Conclusions: The use of a suction cup on a piston-based chest compression device did not increase end tidal carbon dioxide, but it was associated to a higher coronary perfusion pressure.

Place, publisher, year, edition, pages
Elsevier, 2022. Vol. 12, article id 100311
Keywords [en]
Mechanical chest compression, Coronary perfusion pressure, Cerebral oxygenation, suction cup, Piston-based device
National Category
Anesthesiology and Intensive Care
Identifiers
URN: urn:nbn:se:uu:diva-487295DOI: 10.1016/j.resplu.2022.100311ISI: 000868311000003PubMedID: 36193235OAI: oai:DiVA.org:uu-487295DiVA, id: diva2:1707015
Funder
Uppsala UniversityAvailable from: 2022-10-28 Created: 2022-10-28 Last updated: 2026-03-16Bibliographically approved
In thesis
1. Exploring ventilation during cardiopulmonary resuscitation: Experimental and clinical insights
Open this publication in new window or tab >>Exploring ventilation during cardiopulmonary resuscitation: Experimental and clinical insights
2026 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Ventilation during cardiopulmonary resuscitation remains understudied with current guideline recommendations for the treatment relying on low level evidence and expert opinion. The aim of this doctoral project was to explore ventilation during cardiopulmonary resuscitation, both in the experimental and clinical setting.

Study I investigated whether a suction cup on a mechanical chest compression device intended to assist chest recoil affected the haemodynamics and ventilation in an experimental porcine model. No difference in EtCO2, as a measurement of cardiac output, or ventilation could be found, although the suction cup increased the coronary perfusion pressure.

In study II, ventilation parameters, haemodynamics, blood gases and lung injuries were compared between ventilation during continuous chest compressions and ventilations given during a pause of the chest compressions (30:2) in an experimental porcine model. Continuous chest compressions were associated with higher peak inspiratory pressure, lower EtCO2 and PaCO2. No differences were found with regards to lung injuries between the groups.

Study III aimed to develop and test a novel algorithm designed to extract accurate ventilation parameters from ventilation waveform signals, gathered during experimental CPR, in the presence of chest compression artefacts in the signal, that otherwise interferes with the parameter extraction. The algorithm was tested with a pneumotacography device and with mechanical ventilators giving ventilation parameters with known values. The algorithm deviated only slightly from the ventilator settings and outperformed the standard software of the pneumotachograph.

Study IV was an observational multicentre study that aimed to describe ventilation parameters during cardiopulmonary resuscitation. Patients were included from five sites, four out of hospital and one in hospital. Included in the study were 241 patients and 28120 ventilations. The ventilations were heterogenous and varied with airway modality and ventilation mode. Bag-valve-mask ventilations were associated with large levels of leakage and asynchronous ventilations with endotracheal tubes with high airway pressures. No obvious signs of hyperventilation were found.

Future research on cardiopulmonary resuscitation should when possible include measurements of ventilation, in order to deduce if the varying ventilation parameters affects outcomes and to decide optimal ventilation strategies for survival.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2026. p. 99
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, ISSN 1651-6206 ; 2244
Keywords
Cardiac arrest, cardiopulmonary resuscitation, ventilation, ventilation parameters, advanced life support
National Category
Anesthesiology and Intensive Care
Research subject
Medical Science
Identifiers
urn:nbn:se:uu:diva-581885 (URN)978-91-513-2773-0 (ISBN)
Public defence
2026-05-08, H:son Holmdahlsalen, Akademiska sjukhuset ing 100, Dag Hammarskjölds väg 8, Uppsala, 13:00 (Swedish)
Opponent
Supervisors
Available from: 2026-04-17 Created: 2026-03-16 Last updated: 2026-04-17

Open Access in DiVA

fulltext(641 kB)427 downloads
File information
File name FULLTEXT01.pdfFile size 641 kBChecksum SHA-512
e6e1121b6a24c5d7f2b192f263a68c77d9ffbaef1cdb2a5a342e8f8f38f3bf7d326f9bb24b74c67bb052d0434638d4e947bbb91a03aa7c93065c79623144d6ec
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Authority records

Mälberg, JohanSmekal, DavidLipcsey, MiklósRubertsson, Sten

Search in DiVA

By author/editor
Mälberg, JohanSmekal, DavidLipcsey, MiklósRubertsson, Sten
By organisation
Anaesthesiology and Intensive CareHedenstierna laboratory
In the same journal
Resuscitation Plus
Anesthesiology and Intensive Care

Search outside of DiVA

GoogleGoogle Scholar
Total: 430 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 265 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf