Logo: to the web site of Uppsala University

uu.sePublications from Uppsala University
System disruptions
There are recurring service disruptions on some of the search portals due to high traffic. We are working to resolve the issue, you may temporarily encounter an error message.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Hydroxyapatite particle shape affects screw attachment in cancellous bone when augmented with hydroxyapatite-containing hydrogels
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Materials Science and Engineering, Applied Material Science. (Biomaterial Systems (BMS))ORCID iD: 0000-0003-3961-0466
Uppsala University, Disciplinary Domain of Science and Technology, Chemistry, Department of Chemistry - Ångström, Macromolecular Chemistry.
Uppsala University, Disciplinary Domain of Science and Technology, Chemistry, Department of Chemistry - Ångström, Macromolecular Chemistry.ORCID iD: 0000-0002-6977-0711
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Materials Science and Engineering, Applied Material Science. (Biomaterial Systems (BMS))ORCID iD: 0000-0002-3219-1177
Show others and affiliations
2024 (English)In: Journal of The Mechanical Behavior of Biomedical Materials, ISSN 1751-6161, E-ISSN 1878-0180, Vol. 150, article id 106241Article in journal (Refereed) Published
Abstract [en]

Screw-bone construct failures are a true challenge in orthopaedic implant fixation, particularly in poor quality bone. Whilst augmentation with polymeric or ceramic bone cement can improve the primary stability of the screws, the cement may block the flow of blood and nutrients and hamper bone remodelling. In this study, soft, non-setting biomaterials based on Hyalectin gels and hydroxyapatite (HA) particles with different morphological parameters were evaluated as potential augmentation materials, using a lapine ex vivo bone model. The pull-out force, stiffness, and work to fracture were considered in evaluating screw attachment. The pull-out force of constructs reinforced with Hyalectin containing irregularly shaped nano-HA and spherically shaped micro-HA particles were found to be significantly higher than the control group (no augmentation material). The pull-out stiffness increased for the micro-HA particles and the work to fracture increased for the irregular nano-HA particles. However, there were no significant augmentation effect found for the spherical shaped nano-HA particles. In conclusion, injectable Hyalectin gel loaded with hydroxyapatite particles was found to have a potentially positive effect on the primary stability of screws in trabecular bone, depending on the HA particle shape and size.

Place, publisher, year, edition, pages
Elsevier, 2024. Vol. 150, article id 106241
Keywords [en]
Hydroxyapatite, hyaluronic acid, screw-bone primary stability, screw augmentation, pull-out
National Category
Composite Science and Engineering Applied Mechanics
Research subject
Engineering Science with specialization in Biomedical Engineering
Identifiers
URN: urn:nbn:se:uu:diva-514604DOI: 10.1016/j.jmbbm.2023.106241ISI: 001124096700001PubMedID: 37995601OAI: oai:DiVA.org:uu-514604DiVA, id: diva2:1805959
Funder
EU, Horizon 2020, 812765Available from: 2023-10-19 Created: 2023-10-19 Last updated: 2024-01-04Bibliographically approved
In thesis
1. Mechanical optimization of orthopaedic bone screw constructs
Open this publication in new window or tab >>Mechanical optimization of orthopaedic bone screw constructs
2023 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Orthopaedic screw implants are crucial in surgical procedures for bone structures, with a longstanding issue being screw loosening. Improving screw stability requires an enhanced understanding of the bone-implant interactions and associated failure mechanisms. This knowledge can be used to optimize screw designs.

In this thesis, a first step towards this end was taken through the development of enhanced trabecular bone models. Due to the trabecular bone's complex structure and the difficulties in obtaining micro-structural information, we proposed a numerical model based on Voronoi tessellation to mimic the trabecular bone morphology across varying porosities. This model's mechanical properties aligned well with analytical formulas and finite element modelling of real bone specimens, showing strong agreement with experimental results.

Further investigation into screw-trabecular bone interaction was carried out using two numerical models. The explicit finite element models were able to replicate experimental screw push-in results. While only one of the models accounted for the screw insertion step, both models showed strong congruence with key experimental results. The two-step simulation however led to a more physically plausible Young’s modulus for trabecular bone material.

Utilizing a validated numerical model, a numerical optimization process was initiated, where novel screw designs were proposed. Several neural network surrogate models were introduced, reducing evaluation costs while maintaining prediction accuracy. We found that screw insertion position, trabecular bone porosity, and orientation were significant factors, explaining about 96% of the variance in predicted response. 

Furthermore, a neural network workflow was developed to generate super-resolution trabecular bone models from clinical CT data, improving accuracy by up to 700% both morphologically and mechanically, using micro-CT models as a benchmark.

Lastly, the potential enhancement of screw's primary stability was explored, by injection of hyaluronic acid mixed with hydroxyapatite particles. The augmentation effect was influenced by the hydroxyapatite particles' size and shape. Considering that these particles can also promote bone growth, a particle-laden hydrogel injection could potentially enhance screw stability throughout its lifespan.

In conclusion, this study proposed methods to elucidate bone-implant interaction and enhance screw stability in trabecular bone, encompassing trabecular bone modelling, bone-screw interaction investigations, screw geometric optimization, super-resolution trabecular bone model generation from clinical CT data, and hydrogel optimization for stability. The results provide an enhanced understanding as well as optimization of complex geometric interactions, and could lead to future enhancements of clinical practice in terms of screw stability.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2023. p. 60
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 2332
Keywords
Trabecular bone, screw implant, explicit finite element modelling, computed tomography, numerical optimization, neural network, hydrogel
National Category
Applied Mechanics Medical Imaging Composite Science and Engineering
Research subject
Engineering Science with specialization in Biomedical Engineering
Identifiers
urn:nbn:se:uu:diva-514626 (URN)978-91-513-1943-8 (ISBN)
Public defence
2023-12-07, Polhemsalen, Lägerhyddsvägen 1, Uppsala, 09:15 (English)
Opponent
Supervisors
Available from: 2023-11-15 Created: 2023-10-19 Last updated: 2025-02-09

Open Access in DiVA

fulltext(3747 kB)416 downloads
File information
File name FULLTEXT01.pdfFile size 3747 kBChecksum SHA-512
c3c8e58cd0e22d8e231d4d022a27eebd8d12a35730fbb3a885c45ef8f3a5dfa5a5704fa50c4afc34a2d1b8590450335d910cfd09f744be197976db5ae4f934aa
Type fulltextMimetype application/pdf

Other links

Publisher's full textPubMed

Authority records

Samanta, AyanProcter, PhilipPersson, Cecilia

Search in DiVA

By author/editor
Zhou, YijunSamanta, AyanProcter, PhilipPersson, Cecilia
By organisation
Applied Material ScienceMacromolecular Chemistry
In the same journal
Journal of The Mechanical Behavior of Biomedical Materials
Composite Science and EngineeringApplied Mechanics

Search outside of DiVA

GoogleGoogle Scholar
Total: 422 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 431 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf