Eigen-analysis of hydraulic-mechanical-electrical coupling mechanism for small signal stability of hydropower plant
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity. Wuhan Univ, State Key Lab Water Resources & Hydropower Engn S, Wuhan 430072, Hubei, Peoples R China..ORCID iD: 0000-0003-1638-0792
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity. Vattenfall R&D, SE-81426 Älvkarleby, Sweden..
Univ Saskatchewan, Dept Elect & Comp Engn, Saskatoon, SK S7N 5A9, Canada..
Wuhan Univ, State Key Lab Water Resources & Hydropower Engn S, Wuhan 430072, Hubei, Peoples R China..
Show others and affiliations
2018 (English)In: Renewable energy, ISSN 0960-1481, E-ISSN 1879-0682, Vol. 115, p. 1014-1025Article in journal (Refereed) Published
Abstract [en]

Hydropower shoulders important responsibility for regulation and control of power systems with intermittent renewable energy sources. The quality of regulation required for hydropower units has been increasing, and the interaction between hydropower plants (HPPs) and power systems is of great importance. This work aims to conduct a fundamental study on hydraulic-mechanical-electrical coupling mechanism for small signal stability of HPPs. The main focus is the impact of hydraulic-mechanical factors on the local mode oscillation in a Single-Machine-Infinite-Bus system. A twelfth-order state matrix is established for theoretical eigen-analysis as the core approach. Meanwhile, a simulation model based on Simulink/SimPowerSystems is built for validation. The influencing mechanisms of water column elasticity, governor mechanical component, and water inertia are studied under different control modes of the turbine governor. The results show considerable influence from hydraulic-mechanical factors, and the effect of turbine governor actions is no longer ignorable; also, the damping performance under power system stabilizers can be considerably affected. Insights into interactions among physical quantities in various conditions are obtained as well.

Place, publisher, year, edition, pages
2018. Vol. 115, p. 1014-1025
Keywords [en]
Small signal stability, Hydropower plant, Turbine governor, Eigenvalue, Power system stabilizer
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:uu:diva-340668DOI: 10.1016/j.renene.2017.08.005ISI: 000413615500092OAI: oai:DiVA.org:uu-340668DiVA, id: diva2:1180290
Available from: 2018-02-05 Created: 2018-02-05 Last updated: 2020-05-19Bibliographically approved
In thesis
1. Hydropower plants and power systems: Dynamic processes and control for stable and efficient operation
Open this publication in new window or tab >>Hydropower plants and power systems: Dynamic processes and control for stable and efficient operation
2017 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

As the largest global renewable source, hydropower shoulders a large portion of the regulation duty in many power systems. New challenges are emerging from variable renewable energy (VRE) sources, the increasing scale and complexity of hydropower plants (HPPs) and power grid. Stable and efficient operation of HPPs and their interaction with power systems is of great importance.

Theoretical analysis, numerical simulation and on-site measurement are adopted as main study methods in this thesis. Various numerical models of HPPs are established, with different degrees of complexity for different purposes. The majority of the analysis and results are based on eight HPPs in Sweden and China.

Stable operation (frequency stability and rotor angle stability) and efficient operation are two important goals. Regarding the stable operation, various operating conditions are analysed; the response time of primary frequency control (PFC) and the system stability of isolated operation are investigated. A fundamental study on hydraulic-mechanical-electrical coupling mechanisms for small signal stability of HPPs is conducted. A methodology is proposed to quantify the contribution to the damping of low frequency oscillations from hydraulic turbines. The oscillations, with periods ranging from less than one up to hundreds of seconds, are analysed.

Regarding the efficient operation, a description and an initial analysis of wear and tear of turbines are presented; a controller filter is proposed as a solution for wear reduction of turbines and maintaining the frequency quality of power systems; then the study is further extended by proposing a framework that combines technical plant operation with economic indicators, to obtain relative values of regulation burden and performance of PFC.

The results show that the coupling between the hydraulic-mechanical subsystem and the electrical subsystem can be considerable and should be considered with higher attention. Effectiveness and applicability of different numerical models are shown, supplying suggestions for further model optimization. For the influence from power systems on HPPs, the dynamic processes and corresponding control strategies of HPPs under diverse disturbances and requirements from power systems are addressed. For the influence from HPPs on power systems, quantifications of frequency quality and the hydraulic damping are conducted utilising proposed methodologies.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2017. p. 140
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1494
National Category
Engineering and Technology
Identifiers
urn:nbn:se:uu:diva-318470 (URN)978-91-554-9871-9 (ISBN)
Public defence
2017-05-19, Polhemsalen, Ångtröm 10134, Lägerhyddsvägen 1, Ångströmlaboratoriet, Uppsala, 13:15 (English)
Opponent
Supervisors
Available from: 2017-04-28 Created: 2017-03-24 Last updated: 2020-05-19

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Yang, WeijiaNorrlund, PerLundin, Urban

Search in DiVA

By author/editor
Yang, WeijiaNorrlund, PerLundin, Urban
By organisation
Electricity
In the same journal
Renewable energy
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 258 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf