Low-dose CT of postoperative pelvic fractures: a comparison with radiography
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Radiology.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Orthopaedics.
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Orthopaedics.ORCID iD: 0000-0002-2111-6868
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Faculty of Medicine, Department of Surgical Sciences, Radiology.
Show others and affiliations
2019 (English)In: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 60, no 1, p. 85-91Article in journal (Refereed) Published
Abstract [en]

Background Computed tomography (CT) is superior to conventional radiography (CR) for assessing internal fixation of pelvic fractures, but with a higher radiation exposure. Low-dose CT (LDCT) could possibly have a sufficient diagnostic accuracy but with a lower radiation dose. Purpose To compare postoperative diagnostic accuracy of LDCT and CR after open reduction and internal fixation of pelvic fracture. Material and Methods Twenty-one patients were examined with LDCT and CR 0-9 days after surgery. The examinations were reviewed by two musculoskeletal radiologists. Hardware, degree of fracture reduction, image quality, and reviewing time were assessed, and effective radiation dose was calculated. Inter-reader agreement was calculated. Results LDCT was significantly better than CR in determining whether hardware positioning was assessable ( P < 0.001). Acetabular congruence was assessable in all fractured patients with LDCT. In 12 of the 32 assessments with CR of patients with an acetabular fracture, joint congruence was not assessable due to overlapping hardware ( P = 0.001). Image quality was significantly higher for LDCT. Median time to review was 240 s for LDCT compared to 180 s for CR. Effective dose was 0.79 mSv for LDCT compared to 0.32 mSv for CR ( P < 0.001). Conclusion LDCT is more reliable than CR in assessing hardware position and fracture reduction. Joint congruency is sometimes not possible to assess with CR, due to overlapping hardware. The image quality is higher, but also the effective dose, with LDCT than with CR.

Place, publisher, year, edition, pages
2019. Vol. 60, no 1, p. 85-91
Keywords [en]
CT, Low dose computed tomography, image quality, pelvic fracture, radiation dose, radiography
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:uu:diva-350775DOI: 10.1177/0284185118770919ISI: 000453211800011PubMedID: 29665704OAI: oai:DiVA.org:uu-350775DiVA, id: diva2:1206108
Available from: 2018-05-16 Created: 2018-05-16 Last updated: 2026-06-22Bibliographically approved
In thesis
1. Low dose CT in diagnostic orthopaedic imaging
Open this publication in new window or tab >>Low dose CT in diagnostic orthopaedic imaging
2026 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

The aim of the thesis was to compare the methods of CR and LDCT for musculoskeletal imaging of the pelvis, hip and thoracic and lumbar spine to investigate if LDCT can achieve similar or higher diagnostic quality compared to CR, with an equal level of radiation exposure. The comparison focused on image quality, visibility and radiation dose, with the addition of diagnostic findings.

In paper I 21 patients, who had undergone open reduction and internal fixation of pelvic fracture, were examined with CR and LDCT. Hardware positioning, fracture reduction, image quality and radiation dose was noted. In paper II a phantom with hip prosthesis and tantalum markers was scanned with 14 different CT protocols. The image sets were assessed regarding image quality, robustness of numerical data for migration and radiation dose. The protocol with highest overall score and an estimated radiation dose < 1mSv was applied to a pilot patient. In paper III and IV, 63 and 84 patients respectively were examined with routine CR and LDCT with a study protocol. Technical and diagnostic image quality and visibility was assessed. Diagnostic findings were noted. An AI software was used for visibility of vertebrae and fracture detection. Radiation dose was calculated.

LDCT had a significantly higher image quality than CR in the post-operative pelvis and the thoracic and lumbar spine, but also significantly higher radiation doses. LDCT is more reliable in assessing hardware and fracture reduction in the pelvis. LDCT can be used to perform precise migration measurements in patients with hip prosthesis with a radiation dose comparable to CR. More fractures were detected with LDCT than CR in the thoracic spine but not in the lumbar. There was no difference in detected compression fractures in LDCT between AI and radiologists in either thoracic or lumbar spine.

The findings of this thesis indicates that it is possible to examine the pelvis, hips with prosthesis, and thoracic and lumbar spine with LDCT and get as good or better diagnostic information with higher image quality than CR. More work is needed to further reduce radiation dose.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2026. p. 82
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Medicine, ISSN 1651-6206 ; 2283
Keywords
Low dose CT, Radiography, RSA, Image quality, Pelvic fracture, Radiation dose, Thoracic spine, Lumbar spine. Hip prosthesis, Fracture, AI
National Category
Radiology and Medical Imaging
Research subject
Medical Science
Identifiers
urn:nbn:se:uu:diva-590904 (URN)978-91-513-2893-5 (ISBN)
Public defence
2026-09-17, Föreläsningssalen, Röntgenkliniken, ing 70 1tr, Akademiska Sjukhuset, Uppsala, 13:00 (Swedish)
Opponent
Supervisors
Available from: 2026-08-25 Created: 2026-06-22 Last updated: 2026-08-25

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records

Eriksson, ThomasBerg, PerOlerud, ClaesShalabi, AdelHänni, Mari

Search in DiVA

By author/editor
Eriksson, ThomasBerg, PerOlerud, ClaesShalabi, AdelHänni, Mari
By organisation
RadiologyOrthopaedics
In the same journal
Acta Radiologica
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 251 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf