Aspects of modelling and control of MMC based HVDC system
Uppsala University, Disciplinary Domain of Science and Technology, Technology, Department of Engineering Sciences, Electricity. ABB AB.
2018 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Close location of high voltage direct current (HVDC) power transmission lines to high voltage alternating current (HVAC) transmission lines can induce the fundamental frequency AC voltage in HVDC line. For instance, it could happen if both AC and DC lines' conductors are placed on the same power towers.

This induced voltage can cause a DC component of the current on the AC side of the converter if no additional measures or further action to reduce it is taken by the control of the converter. Presence of the DC offset can result in transformer saturation which may cause overheating, efficiency reduction, a shortened lifespan of the devices, voltage harmonics of the secondary winding output [1].

This thesis work shortly explains the physics of the induced voltage in an HVDC transmission line placed close to HVAC line, describes the simulation model of the symmetrical half-bridge (See Figure 2.3) modular multilevel (HB MMC) HVDC system that is used for further analysis, determines the impact of control system of the converter to the DC component of the output current, explains an analytical method of calculation of the DC component of the output current of the HB MMC HVDC converter, compares the results of simulation with theoretically calculated value,explains their difference, and explains possible ways to overcome this problem.

There are different approaches of analysis of dynamics of MMC HVDC converter. Some of them consider the replacement of submodules of the converter with an ideal voltage source, another calculates the ripple of the sum of arm capacitors, a third approach calculates ripple of each capacitor of the converter [2, 3, 4, 5].

In this thesis the dynamics of the sum of arm capacitors is presented. The methodology is based on the research paper [6] and book [7] of Lennart Harnefors.

PSCAD/EMTDC simulation software and the CIGRE B4.57 generic model of HVDC system were used for the verification of the described in this thesis methodology. The CIGRE model as well as model description can be found in open access on their website.

All parameters' values for calculation of the output current DC component were taken from modelling output and compared with the simulation results from the model. According to the simulation results the maximum difference between measured and calculated DC offset reaches 13.7 %.

Suggestions for the development of HB MMC HVDC converter control are made based on the calculation results.

Place, publisher, year, edition, pages
2018. , p. 46
Series
TVE-MFE ; 18006
Keywords [en]
HVDC system, half-bridge submodule, modular multilevel converter, DC component, PSCAD, modelling, electromagnetic interference, converter control, back-to-back converters, circulating current
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:uu:diva-369336OAI: oai:DiVA.org:uu-369336DiVA, id: diva2:1270114
External cooperation
ABB AB
Educational program
Master Programme in Renewable Electricity Production
Presentation
2018-10-26, 2371, Ångström, Lägerhyddsvägen 1, 752 37, Uppsala, 14:15 (English)
Supervisors
Examiners
Available from: 2018-12-13 Created: 2018-12-12 Last updated: 2018-12-13Bibliographically approved

Open Access in DiVA

No full text in DiVA

By organisation
Electricity
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 620 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf