Logo: to the web site of Uppsala University

uu.sePublications from Uppsala University
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Very accurate cryogenic mechanisms for CRIRES+
European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany.
European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany.
European Org Astron Res Southern Hemisphere, Karl Schwarzschild Str 2, D-85748 Garching, Germany.
Osservatorio Arcetri, INAF, Largo E Fermi 5, I-50125 Florence, Italy.
Show others and affiliations
2018 (English)In: OPTICAL AND INFRARED INTERFEROMETRY AND IMAGING VI / [ed] CreechEakman, MJ Tuthill, PG Merand, A, SPIE-INT SOC OPTICAL ENGINEERING , 2018, article id UNSP 107012RConference paper, Published paper (Refereed)
Abstract [en]

After 5 years of operation on the VLT, a large upgrade of CRIRES (the ESO Cryogenic InfraRed Echelle Spectrograph) was decided mainly in order to increase the efficiency. Using a cross dispersion design allows better wavelength coverage per exposure. This means a complete re-design of the cryogenic pre-optic which were including a pre-dispersion stage with a large prism as dispersive element. The new design requires a move of the entrance slit and associated decker toward the first intermediate focal plane right behind the window. Implement 2 functions with high positioning accuracy in a pre-defined and limited space was a real challenge. The design and the test results recorded in the ESO Cryogenic Test Facility are reported in this paper. The second critical function is the grating wheel which positions the 6 cross disperser gratings into the beam. The paper describes the design of the mechanism which includes a detente system in order to guaranty the 5 arc sec positioning reproducibility requested. The design includes also feedback system, based on switches, in order to ensure that the right grating is in position before starting a long exposure. The paper reports on the tests carried out at cryogenic temperature at the sub-system level. It also includes early performances recorded in the instrument along the first phases of the system test.

Place, publisher, year, edition, pages
SPIE-INT SOC OPTICAL ENGINEERING , 2018. article id UNSP 107012R
Series
Proceedings of SPIE, ISSN 0277-786X, E-ISSN 1996-756X ; 10701
Keywords [en]
Cryogenic mechanism, Spectrograph, InfraRed instrument
National Category
Astronomy, Astrophysics and Cosmology
Identifiers
URN: urn:nbn:se:uu:diva-373555DOI: 10.1117/12.2314483ISI: 000452671900080ISBN: 978-1-5106-1956-2 (print)OAI: oai:DiVA.org:uu-373555DiVA, id: diva2:1279354
Conference
Conference on Optical and Infrared Interferometry and Imaging VI, JUN 11-15, 2018, Austin, TX, USA
Available from: 2019-01-16 Created: 2019-01-16 Last updated: 2019-01-16Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Heiter, UlrikeMarquart, Thomas

Search in DiVA

By author/editor
Heiter, UlrikeMarquart, Thomas
By organisation
Observational Astrophysics
Astronomy, Astrophysics and Cosmology

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 342 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf