Logo: to the web site of Uppsala University

uu.sePublications from Uppsala University
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Combined L2-stable feedback and feedforward aeration control in a wastewater treatment plant
Uppsala University, Disciplinary Domain of Science and Technology, Mathematics and Computer Science, Department of Information Technology, Division of Systems and Control. Uppsala University, Disciplinary Domain of Science and Technology, Mathematics and Computer Science, Department of Information Technology, Automatic control.
Uppsala University, Disciplinary Domain of Science and Technology, Mathematics and Computer Science, Department of Information Technology, Division of Systems and Control. Uppsala University, Disciplinary Domain of Science and Technology, Mathematics and Computer Science, Department of Information Technology, Automatic control.ORCID iD: 0000-0003-2580-8906
Uppsala University, Disciplinary Domain of Science and Technology, Mathematics and Computer Science, Department of Information Technology, Division of Systems and Control. Uppsala University, Disciplinary Domain of Science and Technology, Mathematics and Computer Science, Department of Information Technology, Automatic control.
2020 (English)In: IEEE Transactions on Control Systems Technology, ISSN 1063-6536, E-ISSN 1558-0865, Vol. 28, no 3, p. 1017-1024Article in journal (Refereed) Published
Abstract [en]

A nitrifying activated sludge process with ammonium feedback and inflow feedforward control is studied. The feedback and feedforward measurements are subject to time delay and the control loop includes a saturation. A Hammerstein-based model is therefore identified, including process delays and the nonlinearity. A Monod-type nonlinearity is used, as motivated by the oxygen injection efficiency reduction, with increasing dissolved oxygen concentration. The proposed feedback control strategy includes tuning of a linear lag compensator that has a limited low-frequency gain which allows global stability to be established with the Popov criterion. The feedforward controller attenuates the disturbance and provides an overall improvement of the control strategy. The performance of the combined feedback and feedforward aeration controller is evaluated with a benchmark model.

Place, publisher, year, edition, pages
Institute of Electrical and Electronics Engineers (IEEE), 2020. Vol. 28, no 3, p. 1017-1024
National Category
Control Engineering
Identifiers
URN: urn:nbn:se:uu:diva-374737DOI: 10.1109/TCST.2019.2891410ISI: 000528665800025OAI: oai:DiVA.org:uu-374737DiVA, id: diva2:1281915
Available from: 2019-01-23 Created: 2019-01-23 Last updated: 2020-06-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Chistiakova, TatianaWigren, TorbjörnCarlsson, Bengt

Search in DiVA

By author/editor
Chistiakova, TatianaWigren, TorbjörnCarlsson, Bengt
By organisation
Division of Systems and ControlAutomatic control
In the same journal
IEEE Transactions on Control Systems Technology
Control Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 188 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf