Logo: to the web site of Uppsala University

uu.sePublications from Uppsala University
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Nonparametric time-domain tremor quantification with smart phone for therapy individualization
Uppsala University, Disciplinary Domain of Science and Technology, Mathematics and Computer Science, Department of Information Technology, Division of Systems and Control. Uppsala University, Disciplinary Domain of Science and Technology, Mathematics and Computer Science, Department of Information Technology, Automatic control.ORCID iD: 0000-0001-8185-3117
Uppsala University, Disciplinary Domain of Science and Technology, Mathematics and Computer Science, Department of Information Technology, Division of Systems and Control. Uppsala University, Disciplinary Domain of Science and Technology, Mathematics and Computer Science, Department of Information Technology, Automatic control.ORCID iD: 0000-0002-6608-250x
2020 (English)In: IEEE Transactions on Control Systems Technology, ISSN 1063-6536, E-ISSN 1558-0865, Vol. 28, no 1, p. 118-129Article in journal (Refereed) Published
Abstract [en]

This paper deals with a low-complexity time-domain tremor quantification method for individualization of therapies in medical conditions, where tremor is a cardinal symptom. This method produces a tremor severity estimate based on the measurements acquired from a standard sensor platform of a smart phone during a smooth voluntary movement. The estimate is calculated from a data set recorded over tens of seconds but can also be used for unobtrusive tremor monitoring over long time. Besides tremor amplitude, its frequency is also evaluated over time, thus providing the means to distinguish between, e.g., rest and action tremor. No analytical model is assumed for the tremor signal form. The characterization of tremor severity is performed by the steady-state analysis of a Markov chain, whose states correspond to different intervals of tremor amplitude. The utility of the proposed quantification approach is illustrated by clinical data obtained during Deep Brain Stimulation programming sessions. The results are compared with a conventional approach utilizing spectral analysis to demonstrate the benefits of the proposed method.

Place, publisher, year, edition, pages
2020. Vol. 28, no 1, p. 118-129
Keywords [en]
Satellite broadcasting, Smart phones, Medical treatment, Accelerometers, Time-domain analysis, Spectral analysis, Gyroscopes, Biomedical systems, essential tremor (ET), inertial sensors, Markov models, nonparametric modeling, Parkinson's disease (PD), therapy individualization
National Category
Control Engineering
Identifiers
URN: urn:nbn:se:uu:diva-398281DOI: 10.1109/TCST.2018.2881420ISI: 000505786600009OAI: oai:DiVA.org:uu-398281DiVA, id: diva2:1375125
Funder
VinnovaAvailable from: 2018-12-07 Created: 2019-12-04 Last updated: 2020-05-04Bibliographically approved
In thesis
1. Inertial motion capture for ambulatory analysis of human movement and balance
Open this publication in new window or tab >>Inertial motion capture for ambulatory analysis of human movement and balance
2020 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Inertial sensors (accelerometers and gyroscopes) are ubiquitous in today’s society, where they can be found in many of our everyday mobile devices. These sensors are capable of recording the movement of the device, and by extension, the movement of humans carrying or interacting with the device. Human motion capture is frequently used for medical purposes to assess individual balance performance and movement disorders. Accurate and objective assessment is important in the design of individualized interventions and rehabilitation strategies.

The increasing availability of inertial sensors, combined with their mobility and low cost, has made inertial motion capture highly relevant as a more accessible alternative to the laboratory based gold standard. However, mobile solutions need to be adopted for plug-and-play use with the end user in mind. Methods that automatically calibrate the sensors, and methods that detect and record relevant motions are required.

This thesis contributes to the development of human inertial motion capture as a plug-and-play technology. A method for accelerometer calibration, which allows for compensation of systematic sensor errors, is proposed. The method fuses accelerometer and gyroscope data to allow dynamic rotation of the sensor during the calibration procedure. Other proposed methods handles sensor-to-segment calibration in a biomechanical model. The position of a joint center and the direction of a hinge joint’s rotation axis, are identified in each sensor’s intrinsic coordinate system. This is done by fitting recorded motions to the kinematic constraints of the underlying biomechanical model. The methods are evaluated on real sensor data collected from mechanical joint systems that mimics human limbs.

The state of the current knowledge regarding objective human balance assessment isstudied in the form of a systematic review, that includes methods for modeling and identifying neuromuscular control of human balance. A similar modeling framework is then applied to identify feedback controllers in physical and artificial (simulated) systems. Finally, inertial sensors are applied in tremor quantification in Parkinson’s disease (PD) and essential tremor (ET). The method uses only the inertial sensors in a standard smart phone, and is applied on data from human subjects with PD or ET.

Place, publisher, year, edition, pages
Uppsala: Acta Universitatis Upsaliensis, 2020. p. 43
Series
Digital Comprehensive Summaries of Uppsala Dissertations from the Faculty of Science and Technology, ISSN 1651-6214 ; 1946
Keywords
Inertial sensors, Human motion capture, Calibration, Neuromuscular control, Human balance, Tremor quantification
National Category
Control Engineering
Identifiers
urn:nbn:se:uu:diva-409894 (URN)978-91-513-0965-1 (ISBN)
Public defence
2020-08-28, ITC 2446, Polacksbacken, Lägerhyddsvägen 2, Uppsala, 09:15 (English)
Opponent
Supervisors
Funder
Swedish Research Council, 2015-05054
Available from: 2020-06-04 Created: 2020-05-04 Last updated: 2020-06-17

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records

Olsson, FredrikMedvedev, Alexander

Search in DiVA

By author/editor
Olsson, FredrikMedvedev, Alexander
By organisation
Division of Systems and ControlAutomatic control
In the same journal
IEEE Transactions on Control Systems Technology
Control Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 361 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf