Logo: to the web site of Uppsala University

uu.sePublications from Uppsala University
Planned maintenance
A system upgrade is planned for 17/11-2026, at 12:00-13:00. During this time DiVA will be unavailable.
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Effective dose and effect of dose modulation for localizer radiographs using applied and alternative settings on Toshiba/Canon CT systems
Uppsala University, Disciplinary Domain of Medicine and Pharmacy, Disciplinary Domain of Medicine and Pharmacy, research centers etc., Centre for Research and Development, Gävleborg. Gävle Cent Hosp, Dept Imaging & Funct Med, Div Diagnost, Lasarettsvagen 1, S-80188 Gävle, Sweden..ORCID iD: 0000-0003-4754-9626
Uppsala University, Disciplinary Domain of Science and Technology, Biology, Department of Organismal Biology, Systematic Biology.
2021 (English)In: Radiation Protection Dosimetry, ISSN 0144-8420, E-ISSN 1742-3406, Vol. 195, no 3-4, p. 198-204Article in journal (Refereed) Published
Abstract [en]

The purpose was to estimate the effective dose of Toshiba/Canon thorax localizer radiographs for available parameter settings, and to test their dose modulation ability. Localizer radiographs were acquired of anthropomorphic chest phantoms (body mass indices 29 and 23) using various settings (120-80 kV, 100-10 mA). The milliamperes values were compared from resulting helical scan data. Effective dose was computed for two computed tomography (CT) scanners (Aquilion Prime and One Genesis) using a Monte Carlo-based software. For the smaller phantom, all curves were superimposed. For the larger phantom, most curves were also superimposed, except for the one generated from the lowest parameters. The Aquilion Prime system yielded an effective dose of 0.40/0.56 mSv (male/female) using the default parameters. The localizer radiograph dose could be reduced by >90% without affecting the dose modulation. The dose was further reduced by 30-50% in the One Genesis CT system due to improved beam filtration.

Place, publisher, year, edition, pages
Oxford University Press (OUP) Oxford University Press, 2021. Vol. 195, no 3-4, p. 198-204
National Category
Radiology, Nuclear Medicine and Medical Imaging
Identifiers
URN: urn:nbn:se:uu:diva-459016DOI: 10.1093/rpd/ncab030ISI: 000711245400011PubMedID: 33851201OAI: oai:DiVA.org:uu-459016DiVA, id: diva2:1612605
Available from: 2021-11-18 Created: 2021-11-18 Last updated: 2024-01-15Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Authority records

Svahn, Tony MAst, Jennifer C.

Search in DiVA

By author/editor
Svahn, Tony MAst, Jennifer C.
By organisation
Centre for Research and Development, GävleborgSystematic Biology
In the same journal
Radiation Protection Dosimetry
Radiology, Nuclear Medicine and Medical Imaging

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 53 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf