Logo: to the web site of Uppsala University

uu.sePublications from Uppsala University
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Investigating the Impact of Usability on Energy Efficiency of Web-based Personal Health Records.
Show others and affiliations
2021 (English)In: Journal of medical systems, ISSN 0148-5598, E-ISSN 1573-689X, Vol. 45, no 6, p. 65-, article id 65Article in journal (Refereed) Published
Abstract [en]

Usability plays an important role in eHealth applications for their widespread adoption. These software systems have been studied in depth in the literature from this perspective. However, the energy consumption of information systems in the eHealth domain lacks comprehensive research. In this paper, the relationship between the energy consumption of the main components of a PC and the usability evaluations of graphical user interfaces (GUI) were studied in client applications. For this purpose, personal health records (PHR) were used as a case study. A set of 4 web-based PHRs were evaluated with the performance of 20 common tasks in the aforementioned systems. The usability evaluations were carried out by 4 experts. A total of 8 heuristics particularly designed for electronic health record systems and based on the Nielsen usability heuristics were employed. The instantaneous energy values of the power supply and the monitor were collected with an energy consumption measuring equipment. As a result, the following significant correlations were found. In NoMoreClipboard between the Memory heuristic and the power supply (rs = 0.495, p = 0.044), and the Minimalist heuristic and the monitor (rs = - 0.513, p = 0.035). In PatientsLikeMe between the Minimalist heuristic and the power supply (rs = - 0.479, p = 0.083), as well as in the Error heuristic and the power supply (rs = - 0.638, p = 0.014). Finally, in Health Companion between the Match heuristic and the power supply (rs = - 0.481, p = 0.043), and the Error heuristic and the power supply again (rs = - 0.602, p = 0.008). Apart from that, the tasks were divided into those with excellent and fair usability. Those tasks with high usability scores were evaluated to detect whether they also had low energy consumption during task performance. Significant differences were found in PatientsLikeMe with respect to the Error heuristic and the power supply (212.39 ± 18.85W). Significant differences were also found in Health Companion with respect to the Match heuristic and the power supply (199.91 ± 7.19W). The results were discussed to reveal the fundamentals of how implementing usability can impact on energy costs when running client applications.

Place, publisher, year, edition, pages
2021. Vol. 45, no 6, p. 65-, article id 65
Keywords [en]
Energy efficiency, Green software, Personal health records, Software sustainability, Usability, eHealth
National Category
Computer and Information Sciences
Identifiers
URN: urn:nbn:se:uu:diva-515208DOI: 10.1007/s10916-021-01725-8PubMedID: 33959796OAI: oai:DiVA.org:uu-515208DiVA, id: diva2:1807857
Available from: 2023-10-28 Created: 2023-10-28 Last updated: 2023-10-28

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMed

Search in DiVA

By author/editor
Ouhbi, Sofia
In the same journal
Journal of medical systems
Computer and Information Sciences

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 10 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf