Logo: to the web site of Uppsala University

uu.sePublications from Uppsala University
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Performance of newly constructed plastic scintillator barrel in the WASA-FRS experiments and evaluation of radiation damage effects on multi-pixel photon counter
RIKEN, High Energy Nucl Phys Lab, RIKEN Cluster Pioneering Res, Wako, Saitama 3510198, Japan..
RIKEN, Meson Sci Lab, RIKEN Cluster Pioneering Res, Wako, Saitama 3510198, Japan.;RIKEN, Nishina Ctr Accelerator Based Sci, Wako, Saitama 3510198, Japan.;Kyoto Univ, Kyoto 6068502, Japan..
RIKEN, Meson Sci Lab, RIKEN Cluster Pioneering Res, Wako, Saitama 3510198, Japan.;RIKEN, Nishina Ctr Accelerator Based Sci, Wako, Saitama 3510198, Japan.;Univ Osaka, Dept Phys, Osaka 5600043, Japan..
GSI Helmholtzzentrum Schwerionenforsch GmbH, D-64291 Darmstadt, Germany..
Show others and affiliations
2026 (English)In: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, ISSN 0168-9002, E-ISSN 1872-9576, Vol. 1083, article id 171065Article in journal (Refereed) Published
Abstract [en]

A barrel-shaped plastic scintillation counter with Multi-Pixel Photon Counter (MPPC) readout has been developed and operated in the first WASA-FRS experimental campaign at GSI. The detector was used to measure charged particles emitted from reactions induced by a 2.5 GeV proton beam incident on a carbon target, providing particle identification in combination with momentum reconstruction in a 1 T magnetic field. The performance of this detector, particularly its response to energy deposition and time resolution, was systematically investigated as a function of count rate and total number of irradiating protons. A time resolution of 45-75 ps (σ), depending on the energy deposition, was achieved. Stable performance was maintained under high-rate conditions up to 1.35 MHz per single counter, with no significant degradation in either signal amplitude or timing response. Radiation-induced damage to the MPPCs was observed primarily as a reduction in signal amplitude, with approximately 35% decrease at an estimated 1 MeV neutron-equivalent fluence of 2.4 x 1010 cm-2.

Place, publisher, year, edition, pages
Elsevier, 2026. Vol. 1083, article id 171065
Keywords [en]
Silicon photomultiplier, MPPC, Plastic scintillator, Timing counter, Radiation damage, High counting rate performance
National Category
Subatomic Physics
Identifiers
URN: urn:nbn:se:uu:diva-571310DOI: 10.1016/j.nima.2025.171065ISI: 001603472000001Scopus ID: 2-s2.0-105018913342OAI: oai:DiVA.org:uu-571310DiVA, id: diva2:2012888
Funder
EU, Horizon 2020, 824093Available from: 2025-11-11 Created: 2025-11-11 Last updated: 2025-11-11Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Ruber, Roger

Search in DiVA

By author/editor
Ruber, Roger
By organisation
FREIA
In the same journal
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Subatomic Physics

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 47 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf