Intrarenal Fluid Temperature During Laser Lithotripsy: A Mini Review by the European Association of Urology Endourology SectionShow others and affiliations
2025 (English)In: European Urology Focus, E-ISSN 2405-4569, Vol. 11, no 5, p. 221-224Article, review/survey (Refereed) Published
Abstract [en]
Laser lithotripsy involves thermal risks due to heat generated in the surrounding fluid. The concept of thermal dose, which accounts for both temperature and exposure duration, provides a more nuanced understanding of tissue tolerance than fixed temperature thresholds, considering both the magnitude of the temperature increase and the length of exposure to each specific temperature. The concept of a thermal safety distance defines the spatial extent of potential damage, supporting safe power limits of 10 W in the ureter and 20 W in the kidney. Importantly, the type of laser (holmium:YAG, thulium fiber, or thulium:YAG) does not independently affect the rise in temperature, which is primarily driven by the amount of energy absorbed by water in the surrounding tissue. Temperature-related tissue injury can be mitigated by optimizing the flow of the irrigation fluid and the laser power settings and activation patterns.
Place, publisher, year, edition, pages
Elsevier, 2025. Vol. 11, no 5, p. 221-224
Keywords [en]
Intrarenal temperature, Laser lithotripsy, Thermal dose, Thermal safety distance
National Category
Urology Nephrology
Identifiers
URN: urn:nbn:se:uu:diva-575228DOI: 10.1016/j.euf.2025.05.009ISI: 001632861700001PubMedID: 40473536Scopus ID: 2-s2.0-105007455133OAI: oai:DiVA.org:uu-575228DiVA, id: diva2:2026502
2026-01-092026-01-092026-01-09Bibliographically approved